NONIONIC CONTRAST-MEDIA - A COMPARISON OF IODINE DELIVERY RATES DURING MANUAL INJECTION ANGIOGRAPHY

被引:15
作者
HUGHES, PM
BISSET, R
机构
[1] N MANCHESTER GRP HOSP,DEPT RADIOL,MANCHESTER,ENGLAND
[2] HOPE HOSP,DEPT RADIOL,SALFORD M6 8HD,LANCS,ENGLAND
关键词
CONTRAST MEDIA; INJECTION RATE; ARTERIOGRAPHY;
D O I
10.1259/0007-1285-64-761-417
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Iodine delivery rates (IDR) of five commonly used non-ionic contrast media were determined at room temperature (24-degrees-C) and body temperature (37-degrees-C). Contrast media of strength 300 mgI/ml were also evaluated at 50% dilution (150 mgI/ml) with N-saline. Iodine delivery differed significantly (p < 0.005) between samples at room temperature: Omnipaque 350 (1163 mg/s) < Niopam 370 (1311 mg/s) < Omnipaque 300 (1422 mg/s) < Niopam 300 (1635 mg/s) and Ultravist 300 (1636 mg/s). Niopam 300 and Ultravist 300 delivered 41% more iodine per second than Omnipaque 350 at room temperature. Similar differences were identified at body temperature, while delivery of individual media was on average 23.5% greater than at room temperature. No significant differences between iodine delivery rates of diluted media at room temperature or body temperature was identified. The results demonstrate that iodine delivery and hence vascular opacification are better achieved during hand-injection arteriography by using relatively low viscosity media such as Niopam 300 or Ultravist 300. In digital subtraction arteriography all 300 strength contrast media diluted to 150 strength are equally effective.
引用
收藏
页码:417 / 419
页数:3
相关论文
共 50 条
  • [41] FLOW CYTOMETRIC EVALUATION OF PLATELET ACTIVATION BY IONIC OR NONIONIC CONTRAST-MEDIA AND MODULATION BY HEPARIN AND RECOMBINANT HIRUDIN
    KOZA, MJ
    SHANKEY, TV
    WALENGA, JM
    MONCADA, R
    FAREED, J
    PIFARRE, R
    INVESTIGATIVE RADIOLOGY, 1995, 30 (02) : 90 - 97
  • [42] PREDICTION OF SEVERE ADVERSE REACTIONS TO IONIC AND NONIONIC CONTRAST-MEDIA IN JAPAN - EVALUATION OF PRETESTING - A REPORT FROM THE JAPANESE-COMMITTEE-ON-THE-SAFETY-OF-CONTRAST-MEDIA
    YAMAGUCHI, K
    KATAYAMA, H
    TAKASHIMA, T
    KOZUKA, T
    SEEZ, P
    MATSUURA, K
    RADIOLOGY, 1991, 178 (02) : 363 - 367
  • [43] EFFECTS OF NONIONIC MONOMERIC AND DIMERIC CONTRAST-MEDIA ON THE TWITCHING REACTION OF THE RAT - IMPORTANCE OF OSMOLALITY AND ELECTROLYTE CONTENT
    BAATH, L
    BESJAKOV, J
    PETTERSSON, G
    INVESTIGATIVE RADIOLOGY, 1994, 29 (11) : 985 - 989
  • [44] Iodine delivery rate of different concentrations of iodine-containing contrast agents with rapid injection
    Knollmann, F
    Schimpf, K
    Felix, R
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (06): : 880 - 884
  • [45] EFFECTS OF CONTRAST-MEDIA ON THE RR AND QT INTERVAL DURING CORONARY ARTERIOGRAPHY
    MITSUMORI, M
    HAYAKAWA, K
    SOGA, T
    MAEDA, M
    TORIZUKA, T
    OKUNO, Y
    MISAKI, T
    DOKOH, S
    ACTA RADIOLOGICA, 1991, 32 (02) : 120 - 123
  • [46] Evaluating a New Contrast Media Injection System in Coronary CT Angiography
    Martin, Simon S.
    Giovagnoli, Dante A.
    Vingiani, Vincenzo
    Abadia, Andres F.
    Fischer, Andreas M.
    Smith, Hubert E.
    Wertis, Elyse M.
    Hook, Kelly
    Smith, Sandra N.
    Wasden, Tiffany
    Kaminski, Jenny
    Varga-Szemes, Akos
    Vogl, Thomas J.
    Schoepf, U. Joseph
    RADIOLOGIC TECHNOLOGY, 2021, 92 (03) : 232 - 239
  • [47] EFFECT OF VARYING RATES OF LOW-OSMOLARITY CONTRAST-MEDIA INJECTION FOR HEPATIC CT - CORRELATION WITH INDOCYANINE GREEN TRANSIT-TIME
    HARMON, BH
    BERLAND, LL
    LEE, JY
    RADIOLOGY, 1992, 184 (02) : 379 - 382
  • [48] Contrast media reactions and extravasation: Relationship to intravenous injection rates
    Jacobs, JE
    Birnbaum, BA
    Langlotz, CP
    RADIOLOGY, 1998, 209 (02) : 411 - 416
  • [49] CONTRAST-MEDIA INJECTION IN THE RAT AFTER MULTIPLE RENAL INSULTS - NO EVIDENCE OF ADDITIONAL NEPHROTOXICITY
    VERBAEYS, A
    RINGOIR, S
    PRAET, M
    VANMAELE, G
    LAMEIRE, N
    UROLOGICAL RESEARCH, 1995, 23 (01): : 39 - 43
  • [50] EFFECTS OF IOXAGLATE AND NONIONIC CONTRAST-MEDIA ON ERYTHROCYTES FILTERABILITY AND MORPHOLOGY - REVIEW OF PREVIOUS STUDIES AND EVALUATION OF CLINICAL RELEVANCE
    ZANNAD, F
    IDEE, JM
    NAINDITDUCRET, M
    BALUT, C
    HUNTSMAN, A
    LEMIGNON, MM
    DONADIEU, AM
    PIKON, A
    DOUCET, D
    CLINICAL HEMORHEOLOGY, 1992, 12 (03): : 357 - 368