NONIONIC CONTRAST-MEDIA - A COMPARISON OF IODINE DELIVERY RATES DURING MANUAL INJECTION ANGIOGRAPHY

被引:15
|
作者
HUGHES, PM
BISSET, R
机构
[1] N MANCHESTER GRP HOSP,DEPT RADIOL,MANCHESTER,ENGLAND
[2] HOPE HOSP,DEPT RADIOL,SALFORD M6 8HD,LANCS,ENGLAND
关键词
CONTRAST MEDIA; INJECTION RATE; ARTERIOGRAPHY;
D O I
10.1259/0007-1285-64-761-417
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Iodine delivery rates (IDR) of five commonly used non-ionic contrast media were determined at room temperature (24-degrees-C) and body temperature (37-degrees-C). Contrast media of strength 300 mgI/ml were also evaluated at 50% dilution (150 mgI/ml) with N-saline. Iodine delivery differed significantly (p < 0.005) between samples at room temperature: Omnipaque 350 (1163 mg/s) < Niopam 370 (1311 mg/s) < Omnipaque 300 (1422 mg/s) < Niopam 300 (1635 mg/s) and Ultravist 300 (1636 mg/s). Niopam 300 and Ultravist 300 delivered 41% more iodine per second than Omnipaque 350 at room temperature. Similar differences were identified at body temperature, while delivery of individual media was on average 23.5% greater than at room temperature. No significant differences between iodine delivery rates of diluted media at room temperature or body temperature was identified. The results demonstrate that iodine delivery and hence vascular opacification are better achieved during hand-injection arteriography by using relatively low viscosity media such as Niopam 300 or Ultravist 300. In digital subtraction arteriography all 300 strength contrast media diluted to 150 strength are equally effective.
引用
收藏
页码:417 / 419
页数:3
相关论文
共 50 条
  • [1] A COMPARISON OF HEPARINIZED LOW OSMOLALITY IONIC AND NONIONIC CONTRAST-MEDIA IN 500 PATIENTS UNDERGOING CARDIAC ANGIOGRAPHY
    FELDMAN, RL
    CLINICAL CARDIOLOGY, 1990, 13 (11) : 794 - 796
  • [2] CHANGES IN SERUM MAGNESIUM DURING EXCRETORY UROGRAPHY - A COMPARISON OF IONIC AND NONIONIC CONTRAST-MEDIA
    SAHLER, LG
    PRENTICE, LI
    MORRIS, TW
    SEGAL, AJ
    INVESTIGATIVE RADIOLOGY, 1992, 27 (08) : 628 - 631
  • [3] LATE ADVERSE REACTIONS TO NONIONIC CONTRAST-MEDIA
    YOSHIKAWA, H
    RADIOLOGY, 1992, 183 (03) : 737 - 740
  • [4] RISK OF THROMBOEMBOLISM DURING DIAGNOSTIC AND INTERVENTIONAL CARDIAC PROCEDURES WITH NONIONIC CONTRAST-MEDIA
    HWANG, MH
    PIAO, ZE
    MURDOCK, DK
    MESSMORE, HL
    GIARDINA, JJ
    SCANLON, PJ
    RADIOLOGY, 1990, 174 (02) : 453 - 457
  • [5] LACK OF INHIBITION OF THROMBIN GENERATION BY NONIONIC CONTRAST-MEDIA
    MAMON, JF
    FAREED, J
    HOPPENSTEADT, D
    MONCADA, R
    THROMBOSIS RESEARCH, 1991, 61 (02) : 165 - 170
  • [6] RENAL EFFECTS OF NONIONIC CONTRAST-MEDIA AFTER CARDIOANGIOGRAPHY
    JAKOBSEN, JA
    BERG, KJ
    BRODAHL, U
    LAAKE, B
    MOXNESS, A
    ACTA RADIOLOGICA, 1994, 35 (02) : 191 - 196
  • [7] USE OF INFORMED CONSENT FOR IONIC AND NONIONIC CONTRAST-MEDIA
    LAMBE, HA
    HOPPER, KD
    MATTHEWS, YL
    RADIOLOGY, 1992, 184 (01) : 145 - 148
  • [8] CHROMOSOME-DAMAGE FROM NONIONIC CONTRAST-MEDIA
    COCHRAN, ST
    NORMAN, A
    INVESTIGATIVE RADIOLOGY, 1994, 29 : S206 - S207
  • [9] Changes in the fibrinolytic system during angiography with ionic and with nonionic contrast media
    Kielpinska, K
    Walecki, J
    Giedrojc, J
    Turowska, A
    Kordecki, K
    ACADEMIC RADIOLOGY, 2002, 9 (03) : 283 - 289
  • [10] REACTIONS TO IODINE-BASED CONTRAST-MEDIA
    PORRI, F
    PRADAL, M
    FONTAINE, JL
    CHARPIN, D
    VERVLOET, D
    PRESSE MEDICALE, 1993, 22 (11): : 543 - &