ONLINE FERMENTATION PROCESS MONITORING OF CARBOHYDRATES AND ETHANOL USING TANGENTIAL FLOW FILTRATION AND COLUMN LIQUID-CHROMATOGRAPHY

被引:54
作者
BUTTLER, TA
JOHANSSON, KAJ
GORTON, LGO
MARKOVARGA, GA
机构
[1] Department of Analytical Chemistry, University of Lund, S-221 00 Lund
关键词
D O I
10.1021/ac00067a014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes a fully automated on-line system for the unattended monitoring of bioprocesses. Removal of solids and macromolecules from fermentation broth is achieved with a tangential flow filtration unit (Waters Filter/Acquisition Module). The obtained filtrate is transported in a flow system to a cleanup step, based on solid-phase extraction, followed by introduction into a column liquid chromatographic system. Carbohydrates are then detected by refractive index and ethanol content using a laboratory-made selective amperometric alcohol biosensor. Data acquisition and processing, as well as switching of the system valves, are performed by a computer. The on-line system was used for continuous monitoring of five carbohydrates and ethanol during 24-h ethanol fermentations. Waste water from the Swedish pulp industry was used as the technical substrate. Typical RSD values of the entire setup were on the order of 5-6% over a 24-h period of operation.
引用
收藏
页码:2628 / 2636
页数:9
相关论文
共 67 条
[11]   A CONTINUOUS METHOD FOR MONITORING AND CONTROLLING FERMENTATIONS - USING AN AUTOMATED HPLC SYSTEM [J].
DINWOODIE, RC ;
MEHNERT, DW .
BIOTECHNOLOGY AND BIOENGINEERING, 1985, 27 (07) :1060-1062
[12]   2-STAGE STEAM PRETREATMENT OF WILLOW FOR INCREASED PENTOSE YIELD [J].
EKLUND, R ;
GALBE, M ;
ZACCHI, G .
JOURNAL OF WOOD CHEMISTRY AND TECHNOLOGY, 1988, 8 (03) :379-392
[13]  
EKLUND R, 1988, 8 INT S ALC FUELS TO, P101
[14]  
ELMROTH I, 1992, BIOTECHNOL BIOENG, V35, P787
[15]   ONLINE MONITORING AND CONTROL OF FERMENTATION PROCESSES BY FLOW-INJECTION ANALYSIS [J].
FORMAN, LW ;
THOMAS, BD ;
JACOBSON, FS .
ANALYTICA CHIMICA ACTA, 1991, 249 (01) :101-111
[16]   A FLOW-INJECTION ANALYSIS SYSTEM FOR FERMENTATION MONITORING AND CONTROL [J].
GARN, M ;
GISIN, M ;
THOMMEN, C ;
CEVEY, P .
BIOTECHNOLOGY AND BIOENGINEERING, 1989, 34 (04) :423-428
[17]   STABILIZATION OF ANALYTICAL ENZYMES USING A NOVEL POLYMER CARBOHYDRATE SYSTEM AND THE PRODUCTION OF A STABILIZED, SINGLE REAGENT FOR ALCOHOL ANALYSIS [J].
GIBSON, TD ;
HIGGINS, IJ ;
WOODWARD, JR .
ANALYST, 1992, 117 (08) :1293-1297
[18]   AMPEROMETRIC BIOSENSORS BASED ON AN APPARENT DIRECT ELECTRON-TRANSFER BETWEEN ELECTRODES AND IMMOBILIZED PEROXIDASES - PLENARY LECTURE [J].
GORTON, L ;
JONSSONPETTERSSON, G ;
CSOREGI, E ;
JOHANSSON, K ;
DOMINGUEZ, E ;
MARKOVARGA, G .
ANALYST, 1992, 117 (08) :1235-1241
[19]   SELECTIVE DETECTION IN FLOW-ANALYSIS BASED ON THE COMBINATION OF IMMOBILIZED ENZYMES AND CHEMICALLY MODIFIED ELECTRODES [J].
GORTON, L ;
CSOREGI, E ;
DOMINGUEZ, E ;
EMNEUS, J ;
JONSSONPETTERSSON, G ;
MARKOVARGA, G ;
PERSSON, B .
ANALYTICA CHIMICA ACTA, 1991, 250 (01) :203-248
[20]  
GORTON L, 1993, BIOELECTROANALYSIS, V2, P33