RAPID NMR CARDIOGRAPHY WITH A HALF-ECHO M-MODE METHOD

被引:34
作者
HARDY, CJ [1 ]
PEARLMAN, JD [1 ]
MOORE, JR [1 ]
ROEMER, PB [1 ]
CLINE, HE [1 ]
机构
[1] MASSACHUSETTS GEN HOSP,BOSTON,MA 02114
关键词
MAGNETIC RESONANCE IMAGING; TECHNIQUES; HEART; ANATOMY; BLOOD FLOW;
D O I
10.1097/00004728-199109000-00032
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A real-time NMR cardiac profiling pulse sequence has been developed that incorporates two-dimensional (2D) selective excitation and a half-echo readout. The time resolution has been improved by a factor of two relative to the previous flow-compensated, full-echo version. The technique produces a 2D plot of "beam"-axis position versus time, analogous to M-mode echocardiography. In human subjects, details of valve leaflet motion, intracardiac flow, wall motion, and wall thickening may be observed along optimal lines of sight selected interactively. The pulse sequence uses a low-tip-angle 2D selective-excitation pulse derived from a spiral k-space trajectory to excite a narrow cylinder of magnetization, followed by a half-echo readout gradient oriented along the axis of the cylinder. One-dimensional Fourier transformation of the acquired signal results in a magnetization profile along the length of the cylinder, or beam. The pulse sequence is effectively flow compensated without any additional gradient lobes, because the rapid oscillation in the gradient wave forms of the 2D excitation pulse produces relatively small net gradient moments, and the shortened readout gradient has minimal first-order moment relative to center echo. The signal from moving blood can alternatively be velocity encoded by the addition of bipolar gradients along any of the three axes, producing Doppler-like traces of intracardiac blood flow.
引用
收藏
页码:868 / 874
页数:7
相关论文
共 26 条
[1]   TWO-DIMENSIONAL SPATIALLY SELECTIVE SPIN INVERSION AND SPIN-ECHO REFOCUSING WITH A SINGLE NUCLEAR-MAGNETIC-RESONANCE PULSE [J].
BOTTOMLEY, PA ;
HARDY, CJ .
JOURNAL OF APPLIED PHYSICS, 1987, 62 (10) :4284-4290
[2]   MEASUREMENT OF FLOW WITH NMR IMAGING USING A GRADIENT PULSE AND PHASE DIFFERENCE TECHNIQUE [J].
BRYANT, DJ ;
PAYNE, JA ;
FIRMIN, DN ;
LONGMORE, DB .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (04) :588-593
[3]   FAST MR CARDIAC PROFILING WITH 2-DIMENSIONAL SELECTIVE PULSES [J].
CLINE, HE ;
HARDY, CJ ;
PEARLMAN, JD .
MAGNETIC RESONANCE IN MEDICINE, 1991, 17 (02) :390-401
[4]  
COMPTON RA, 1985, SOC MAGNETIC RESONAN, P956
[5]   MAGNETIC-RESONANCE ANGIOGRAPHY [J].
DUMOULIN, CL ;
HART, HR .
RADIOLOGY, 1986, 161 (03) :717-720
[6]  
FEIGENBAUM H, 1972, ECHOCARDIOGRAPHY
[7]   SPATIAL PRESATURATION - A METHOD FOR SUPPRESSING FLOW ARTIFACTS AND IMPROVING DEPICTION OF VASCULAR ANATOMY IN MR IMAGING [J].
FELMLEE, JP ;
EHMAN, RL .
RADIOLOGY, 1987, 164 (02) :559-564
[8]   THE NMR BLOOD FLOWMETER - DESIGN [J].
HALBACH, RE ;
BATTOCLETTI, JH ;
SALLESCUNHA, SX ;
SANCES, A .
MEDICAL PHYSICS, 1981, 8 (04) :444-451
[9]   CORRECTING FOR NONUNIFORM K-SPACE SAMPLING IN 2-DIMENSIONAL NMR SELECTIVE EXCITATION [J].
HARDY, CJ ;
CLINE, HE ;
BOTTOMLEY, PA .
JOURNAL OF MAGNETIC RESONANCE, 1990, 87 (03) :639-645
[10]   OFF-AXIS SPATIAL LOCALIZATION WITH FREQUENCY MODULATED NUCLEAR MAGNETIC-RESONANCE ROTATING (RHO) PULSES [J].
HARDY, CJ ;
BOTTOMLEY, PA ;
ROEMER, PB .
JOURNAL OF APPLIED PHYSICS, 1988, 63 (09) :4741-4743