THIN-FILM BIENZYME AMPEROMETRIC BIOSENSORS BASED ON POLYMERIC REDOX MEDIATORS WITH ELECTROSTATIC BIPOLAR PROTECTING LAYER

被引:41
作者
BOGUSLAVSKY, L
KALASH, H
XU, Z
BECKLES, D
GENG, L
SKOTHEIM, T
LAURINAVICIUS, V
LEE, HS
机构
[1] INST BIOCHEM,VILNIUS 2021,LITHUANIA
[2] BROOKHAVEN NATL LAB,UPTON,NY 11973
关键词
AMPEROMETRY; BIOSENSORS; REDOX POLYMERS; FERROCENE; GLUCOSE; CHOLESTEROL;
D O I
10.1016/0003-2670(95)00168-Y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Amperometric bienzyme sensors were constructed based on solid graphite electrodes modified with polymer redox mediator, horseradish peroxidase and a variety of oxidases and covered with a bipolar electrostatic protective layer. Glucose, ethanol, choline, glycero-3-phosphate and cholesterol sensors were designed and operated at 0 mV vs. Ag/AgCl using single potential step chronoamperometry. The protection of the sensor against interference from ascorbic acid and linearity of response were provided by a bipolar electrostatic layer. Sensitivities as high as 0.74 mu A cm(-2) mM(-1) of glucose, 0.71 mu A cm(-2) mM(-1) of ethanol 5.7 mu A cm(2) mM(-1) of glycerol-1-phosphate, and 28.3 nA cm(-2) per 10 mu M of choline, were achieved.
引用
收藏
页码:15 / 21
页数:7
相关论文
共 41 条
[1]  
BIERMAN EL, 1984, CURRENT CONCEPTS, V10
[2]  
BOGUSLAVSKY LI, 1980, CURR TOP MEMBR TRANS, V14, P1
[3]  
BOGUSLAVSKY LI, 1992, 2ND P WORLD C BIOS O, P104
[4]   ENZYME SENSOR FOR THE DETERMINATION OF CHOLINE-CONTAINING PHOSPHOLIPIDS IN SOME BIOLOGICAL-FLUIDS [J].
CAMPANELLA, L ;
TOMASSETTI, M ;
SAMMARTINO, MP .
ANALYST, 1988, 113 (01) :77-80
[5]  
Cardosi M. F., 1991, ADV BIOSENSORS, V1, P125
[6]  
CASEX AEG, 1984, ANAL CHEM, V56, P667
[7]   CHARACTERIZATION OF CARRAGEENAN HYDROGEL ELECTRODE COATINGS WITH IMMOBILIZED CATIONIC METAL-COMPLEX REDOX COUPLES [J].
CRUMBLISS, AL ;
PERINE, SC ;
EDWARDS, AK ;
RILLEMA, DP .
JOURNAL OF PHYSICAL CHEMISTRY, 1992, 96 (03) :1388-1394
[8]   ELECTRICAL COMMUNICATION BETWEEN REDOX CENTERS OF GLUCOSE-OXIDASE AND ELECTRODES VIA ELECTROSTATICALLY AND COVALENTLY BOUND REDOX POLYMERS [J].
DEGANI, Y ;
HELLER, A .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1989, 111 (06) :2357-2358
[9]   DIRECT ELECTRICAL COMMUNICATION BETWEEN CHEMICALLY MODIFIED ENZYMES AND METAL-ELECTRODES .2. METHODS FOR BONDING ELECTRON-TRANSFER RELAYS TO GLUCOSE-OXIDASE AND D-AMINO-ACID OXIDASE [J].
DEGANI, Y ;
HELLER, A .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1988, 110 (08) :2615-2620
[10]   DIRECT ELECTRICAL COMMUNICATION BETWEEN CHEMICALLY MODIFIED ENZYMES AND METAL-ELECTRODES .1. ELECTRON-TRANSFER FROM GLUCOSE-OXIDASE TO METAL-ELECTRODES VIA ELECTRON RELAYS, BOUND COVALENTLY TO THE ENZYME [J].
DEGANI, Y ;
HELLER, A .
JOURNAL OF PHYSICAL CHEMISTRY, 1987, 91 (06) :1285-1289