Development and validation of a reversed-phase HPLC method for analysis of tetrahydrozoline hydrochloride in eye drop formulations

被引:16
作者
Al-Rimawi, Fuad [1 ]
Zareer, Wahbeh [2 ]
Rabie, Salah [2 ]
Quod, Mazen [2 ]
机构
[1] Al Quds Univ, Fac Sci & Technol, POB 20002, East Jerusalem, Israel
[2] Birzeit Pharmaceut Co, Ramallah, Palestine
关键词
Tetrahydrozolin; hydrochloride; Validation; Precision; Accuracy; Linearity;
D O I
10.1016/j.jpha.2011.11.001
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
A simple, precise, accurate, and stability-indicating method is developed and validated for analysis of tetrahydrozoline hydrochloride in eye drop formulations. Separation was achieved on a reversed-phase C-8 column (125 mm x 4.6 mm i.d., 5 mu m) using a mobile phase consisting of acetonitrile/phosphate buffer of pH 3.0 (20:80, v/v) at a flow rate of 1.0 mL/min and UV detection at 240 nm. This method is validated according to United States Pharmacopeia requirements for new methods, which include accuracy, precision, selectivity, robustness, and linearity and range. This method shows enough selectivity, accuracy, precision, and linearity and range to satisfy Federal Drug Administration/International Conference on Harmonization regulatory requirements. The current method demonstrates good linearity over the range of 0.025-0.075 mg/mL of tetrahydrozoline with r(2) 0.999. The average recovery of the method is 100.8% with a relative standard deviation of 0.47%. The degree of reproducibility of the results obtained as a result of small deliberate variations in the method parameters and by changing analytical operators has proven that the method is robust and rugged. (C) 2011 Xi'an Jiaotong University. Production and hosting by Elsevier B.V. All rights reserved.
引用
收藏
页码:67 / 70
页数:4
相关论文
共 13 条
[1]   Simultaneous determination of ofloxacin, tetrahydrozoline hydrochloride, and prednisolone acetate by high-performance liquid chromatography [J].
Ali, MS ;
Ghori, M ;
Saeed, A .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2002, 40 (08) :429-433
[2]  
Altuntas TG, 2000, PHARMAZIE, V55, P49
[3]   STABILITY-INDICATING DETERMINATION OF TETRAHYDROZOLINE HYDROCHLORIDE IN OPHTHALMIC SOLUTIONS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
ANDERMANN, G ;
RICHARD, A .
JOURNAL OF CHROMATOGRAPHY, 1984, 298 (01) :189-192
[4]  
[Anonymous], 1996, CPMPICH28095
[5]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC STABILITY-INDICATING ASSAY FOR NAPHAZOLINE AND TETRAHYDROZOLINE IN OPHTHALMIC PREPARATIONS [J].
BAUER, J ;
KROGH, S .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1983, 72 (11) :1347-1349
[6]  
Green M., 1996, PRACTICAL GUIDE ANAL, p309A
[7]  
Huber L., 1998, VALIDATION QUALIFICA, P107
[8]  
International Conference on Harmonization (ICH), 2005, VAL AN PROC PA PH OM
[9]   SIMULTANEOUS HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF ANTAZOLINE PHOSPHATE AND TETRAHYDROZOLINE HYDROCHLORIDE IN OPHTHALMIC SOLUTION [J].
PUGLISI, G ;
SCIUTO, S ;
CHILLEMI, R ;
MANGIAFICO, S .
JOURNAL OF CHROMATOGRAPHY, 1986, 369 (01) :165-170
[10]  
Rojsitthisak P, 2005, PDA J PHARM SCI TECH, V59, P332