DEVELOPMENT OF A MONOLITHIC CONSTANT FRACTION DISCRIMINATOR

被引:10
|
作者
TANAKA, M
IKEDA, H
IKEDA, M
INABA, S
机构
[1] National Laboratory for High Energy Physics, Tsukuba-shi, Ibaraki-ken 305
关键词
ASIC circuits - Constant fraction discriminators - High energy physics experiments - Monolithic discriminators - Nuclear electronics - Timing data;
D O I
10.1109/23.173199
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A constant fraction discriminator was developed with a bipolar ASIC technology from NEC. Prototype chips were examined for their integrity and performance. We are convinced that our design for a constant fraction discriminator would serve as a superior technique for high density integration.
引用
收藏
页码:1321 / 1325
页数:5
相关论文
共 50 条
  • [41] A Constant Fraction Discriminator with Shape-Agnostic Fraction Triggering and Sub-ns Walk for the Solar Probe Analyzer for Ions
    Lee, Lydia
    Abiad, Robert
    Livi, Roberto
    Mirkovic, Mia
    Hatch, Kenneth
    Brunner, Hilary
    Larson, Davin
    Pister, Kristofer S. J.
    2023 IEEE SENSORS, 2023,
  • [42] MONOLITHIC FM DISCRIMINATOR A NEW PIEZOELECTRIC DEVICE
    SMITH, WL
    IEEE TRANSACTIONS ON COMMUNICATION TECHNOLOGY, 1968, CO16 (03): : 460 - &
  • [43] Development of a non-delay line constant fraction discriminator based on the Pade approximant for time-of-flight positron emission tomography scanners
    Kim, S. Y.
    Ko, G. B.
    Kwon, S. I.
    Lee, J. S.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [44] A FAST CONSTANT-FRACTION DISCRIMINATOR FOR E/PI SEPARATION WITH A LEAD SCINTILLATING-FIBER CALORIMETER
    BUONTEMPO, S
    EREDITATO, A
    PARASCANDOLO, L
    RICCARDI, F
    SALMAS, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 327 (2-3): : 509 - 516
  • [45] A MONOLITHIC LIMITER AND BALANCED DISCRIMINATOR FOR FM AND TV RECEIVERS
    BILOTTI, A
    PEPPER, RS
    IEEE TRANSACTIONS ON BROADCAST AND TELEVISION RECEIVERS, 1967, BT13 (03): : 60 - &
  • [46] Design of a constant fraction discriminator for the VFAT3 front-end ASIC of the CMS GEM detector
    Abbaneo, D.
    Abbas, M.
    Abbrescia, M.
    Abdelalim, A. A.
    Akl, M. Abi
    Aboamer, O.
    Acosta, D.
    Ahmad, A.
    Ahmed, W.
    Ahmed, W.
    Aleksandrov, A.
    Aly, R.
    Alfieri, P.
    Asawatangtrakuldee, C.
    Aspell, P.
    Assran, Y.
    Awan, I.
    Bally, S.
    Ban, Y.
    Banerjee, S.
    Barashko, V.
    Barria, P.
    Bencze, G.
    Beni, N.
    Benussi, L.
    Bhopatkar, V.
    Bianco, S.
    Bos, J.
    Bouhali, O.
    Braghieri, A.
    Braibant, S.
    Buontempo, S.
    Calabria, C.
    Caponero, M.
    Caputo, C.
    Cassese, F.
    Castaneda, A.
    Cauwenbergh, S.
    Cavallo, F. R.
    Celik, A.
    Choi, M.
    Choi, S.
    Christiansen, J.
    Cimmino, A.
    Colafranceschi, S.
    Colaleo, A.
    Garcia, A. Conde
    Czellar, S.
    Dabrowski, M. M.
    De Lentdecker, G.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [47] Monolithic integrated S-band frequency discriminator
    Schmegner, K.E.
    Guehl, R.
    1996, Horizon House, Norwood, MA, United States (39)
  • [48] Design and implementation of a compact analog Constant Fraction Discriminator for high-resolution timing in gamma-ray spectroscopy
    Wiebusch, Michael
    JOURNAL OF INSTRUMENTATION, 2024, 19 (12):
  • [49] CONSTANT FRACTION DISCRIMINATOR WITH AUTOMATIC ADJUSTMENT OF OPTIMAL TRIGGERING LEVEL AND AUTOMATIC SUPPRESSION OF AC AND DC INPUT INTERFERENCE SIGNALS
    BIALKOWSKI, J
    SCHOEPS, W
    KOTSCH, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 228 (01): : 110 - 117
  • [50] Off-line correction for excessive constant-fraction- discriminator walk in neutron time-of-flight experiments
    Heilbronn, L
    Iwata, Y
    Iwase, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 522 (03): : 495 - 503