DIAGNOSING BREAST IMPLANT RUPTURE WITH MR-IMAGING, US, AND MAMMOGRAPHY

被引:62
作者
BERG, WA
CASKEY, CI
HAMPER, UM
ANDERSON, ND
CHANG, BW
SHETH, S
ZERHOUNI, EA
KUHLMAN, JE
机构
[1] JOHNS HOPKINS MED INST,RADIOL SERV,BALTIMORE,MD 21287
[2] JOHNS HOPKINS MED INST,DEPT INTERNAL MED,BALTIMORE,MD 21287
[3] JOHNS HOPKINS MED INST,DEPT PLAST & RECONSTRUCT SURG,BALTIMORE,MD 21287
关键词
BREAST; MR; PROSTHESES; US;
D O I
10.1148/radiographics.13.6.8290727
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A total of 135 symptomatic women with 262 breast implants were examined with magnetic resonance (MR) imaging performed with a body coil, ultrasound (US), or both to determine imaging features of implant rupture. Surgical proof was available for 33 women with 62 implants; 24 were ruptured and 38 were intact. Complicated internal structure was the most reliable predictor of implant rupture: Diffuse low-level echoes were seen on sonograms in 56% of ruptured implants; internal membranes (which correspond to the collapsed implant shell) were seen on MR images in 58% of ruptured implants. Fluid droplets were seen within the silicone in 26% of ruptured implants on MR images. Irregular implant contour can be a sign of rupture but is unreliable. Fluid collections around silicone implants are not a sign of rupture. At present, neither US nor conventional MR imaging with a body coil is sufficiently reliable to advocate routine screening of asymptomatic women with breast implants. Evaluation with MR imaging performed with a surface coil is more reliable.
引用
收藏
页码:1323 / 1336
页数:14
相关论文
共 17 条
[11]   SILICONE BREAST IMPLANTS INVIVO - MR IMAGING [J].
GORCZYCA, DP ;
SINHA, S ;
AHN, CY ;
DEBRUHL, ND ;
HAYES, MK ;
GAUSCHE, VR ;
SHAW, WW ;
BASSETT, LW .
RADIOLOGY, 1992, 185 (02) :407-410
[12]   SILICONE IMPLANT RUPTURE - DETECTION WITH US [J].
HARRIS, KM ;
GANOTT, MA ;
SHESTAK, KC ;
LOSKEN, HW ;
TOBON, H .
RADIOLOGY, 1993, 187 (03) :761-768
[13]   SILICONE GRANULOMAS - DETECTION BY ULTRASONOGRAPHY [J].
HERZOG, P .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1989, 84 (05) :856-857
[14]  
HUANG TT, 1978, PLAST RECONSTR SURG, V60, P277
[15]   RUPTURED GEL-FILLED SILICONE BREAST IMPLANTS - SONOGRAPHIC FINDINGS IN 19 CASES [J].
ROSCULET, KA ;
IKEDA, DM ;
FORREST, ME ;
ONEAL, RM ;
RUBIN, JM ;
JEFFRIES, DO ;
HELVIE, MA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 159 (04) :711-716
[16]   FALSE-POSITIVE RADIOGRAPHIC DIAGNOSIS OF BREAST IMPLANT RUPTURE - REPORT OF 2 CASES [J].
SMITH, DS .
ANNALS OF PLASTIC SURGERY, 1985, 14 (02) :166-167
[17]   BREAST IMPLANTS, COMMON COMPLICATIONS, AND CONCURRENT BREAST DISEASE [J].
STEINBACH, BG ;
HARDT, NS ;
ABBITT, PL ;
LANIER, L ;
CAFFEE, HH .
RADIOGRAPHICS, 1993, 13 (01) :95-118