DIAGNOSING BREAST IMPLANT RUPTURE WITH MR-IMAGING, US, AND MAMMOGRAPHY

被引:62
作者
BERG, WA
CASKEY, CI
HAMPER, UM
ANDERSON, ND
CHANG, BW
SHETH, S
ZERHOUNI, EA
KUHLMAN, JE
机构
[1] JOHNS HOPKINS MED INST,RADIOL SERV,BALTIMORE,MD 21287
[2] JOHNS HOPKINS MED INST,DEPT INTERNAL MED,BALTIMORE,MD 21287
[3] JOHNS HOPKINS MED INST,DEPT PLAST & RECONSTRUCT SURG,BALTIMORE,MD 21287
关键词
BREAST; MR; PROSTHESES; US;
D O I
10.1148/radiographics.13.6.8290727
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A total of 135 symptomatic women with 262 breast implants were examined with magnetic resonance (MR) imaging performed with a body coil, ultrasound (US), or both to determine imaging features of implant rupture. Surgical proof was available for 33 women with 62 implants; 24 were ruptured and 38 were intact. Complicated internal structure was the most reliable predictor of implant rupture: Diffuse low-level echoes were seen on sonograms in 56% of ruptured implants; internal membranes (which correspond to the collapsed implant shell) were seen on MR images in 58% of ruptured implants. Fluid droplets were seen within the silicone in 26% of ruptured implants on MR images. Irregular implant contour can be a sign of rupture but is unreliable. Fluid collections around silicone implants are not a sign of rupture. At present, neither US nor conventional MR imaging with a body coil is sufficiently reliable to advocate routine screening of asymptomatic women with breast implants. Evaluation with MR imaging performed with a surface coil is more reliable.
引用
收藏
页码:1323 / 1336
页数:14
相关论文
共 17 条
[1]   THE DIAGNOSIS OF RUPTURED BREAST IMPLANTS [J].
ANDERSEN, B ;
HAWTOF, D ;
ALANI, H ;
KAPETANSKY, D .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1989, 84 (06) :903-907
[2]  
BERG WA, 1993, AJR, V160, P127
[3]  
BREM RF, 1992, J COMPUT ASSIST TOMO, V16, P157
[4]   DISTANT MIGRATION OF SILICONE GEL FROM A RUPTURED BREAST IMPLANT - CASE-REPORT [J].
CAPOZZI, A ;
DUBOU, R ;
PENNISI, VR .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1978, 62 (02) :302-303
[5]  
CASKEY CI, IN PRESS BREAST IMPL
[6]   SILICONE BREAST IMPLANTS - US EVALUATION [J].
DEBRUHL, ND ;
GORCZYCA, DP ;
AHN, CY ;
SHAW, WW ;
BASSETT, LW .
RADIOLOGY, 1993, 189 (01) :95-98
[7]   SCREENING MAMMOGRAPHY IN 350 WOMEN WITH BREAST IMPLANTS - PREVALENCE AND FINDINGS OF IMPLANT COMPLICATIONS [J].
DESTOUET, JM ;
MONSEES, BS ;
OSER, RF ;
NEMECEK, JR ;
YOUNG, VL ;
PILGRAM, TK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 159 (05) :973-978
[8]   RUPTURE OF A SILICONE BAG-GEL BREAST IMPLANT BY CLOSED COMPRESSION CAPSULOTOMY [J].
EISENBERG, HV ;
BARTELS, RJ .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1977, 59 (06) :849-850
[9]   RUPTURE OF INFLATED BREAST IMPLANTS IN CLOSE COMPRESSION CAPSULOTOMY [J].
FELIBERTI, MC ;
ARRILLAGA, A ;
COLON, GA .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1977, 59 (06) :848-848
[10]   AUGMENTATION MAMMAPALSTY - NORMAL AND ABNORMAL FINDINGS WITH MAMMOGRAPHY AND ULTRASOUND [J].
GANOTT, MA ;
HARRIS, KM ;
ILKHANIPOUR, ZS ;
COSTAGRECO, MA .
RADIOGRAPHICS, 1992, 12 (02) :281-295