MECHANISMS OF ANGIOPLASTY IN HEMODIALYSIS FISTULA STENOSES EVALUATED BY INTRAVASCULAR ULTRASOUND

被引:95
作者
DAVIDSON, CJ [1 ]
NEWMAN, GE [1 ]
SHEIKH, KH [1 ]
KISSLO, K [1 ]
STACK, RS [1 ]
SCHWAB, SJ [1 ]
机构
[1] DUKE UNIV,MED CTR,DIV MED,DURHAM,NC 27710
关键词
D O I
10.1038/ki.1991.185
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Quantification of luminal dimensions and the mechanisms by which angioplasty (PTA) corrects non-atheroma venous fistula stenoses have been poorly studied. In 38 consecutive percutaneous balloon angioplasties of hemodialysis fistula stenoses, catheterbased, mechanically-rotated intravascular ultrasound (IVUS) images were obtained along with cineangiography. Images from 24 brachial vein, 11 central vein, 2 graft anastomoses, and 1 brachial artery were quantitatively and qualitatively evaluated. Semiautomated quantitative angiographic stenosis was 64 +/- 13% pre-PTA and reduced to 36 +/- 19% post-PTA (P < 0.001). Post-PTA IVUS minimal lesion diameter and cross sectional area were 5.7 +/- 1.5 mm and 2.9 +/- 1.5 mm2, respectively. With IVUS, mechanisms observed were: vessel dissection in 16 (42%), arterial stretch (defined as vessel diameter: balloon diameter ratio = 0.75 to 1.0) in 19 (50%), and elastic recoil (defined as vessel diameter: balloon diameter ratio < 0.75) in 19 (50%). Compared to angiography, morphologic information provided by IVUS were plaque composition (hard 11%, soft 89%), plaque topography (eccentric 94%, concentric 6%), thrombus (IVUS: N = 6 vs. angio: N = 1), dissection (IVUS: N = 16 vs. angio: N = 1). Thus, IVUS can evaluate lesion morphology and define luminal dimensions after angioplasty. Mechanisms of successful angioplasty of hemodialysis fistula stenosis occur primarily by vessel stretching and dissection, and significant post-PTA narrowing is due to elastic recoil.
引用
收藏
页码:91 / 95
页数:5
相关论文
共 17 条
[1]   MECHANISM OF TRANS-LUMINAL ANGIOPLASTY [J].
BLOCK, PC .
AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (12) :C69-C71
[2]   INTRAVASCULAR ULTRASONOGRAPHY VERSUS DIGITAL SUBTRACTION ANGIOGRAPHY - A HUMAN INVIVO COMPARISON OF VESSEL SIZE AND MORPHOLOGY [J].
DAVIDSON, CJ ;
SHEIKH, KH ;
HARRISON, JK ;
HIMMELSTEIN, SI ;
LEITHE, ME ;
KISSLO, KB ;
BASHORE, TM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (03) :633-636
[3]   ARTERIAL-WALL CHARACTERISTICS DETERMINED BY INTRAVASCULAR ULTRASOUND IMAGING - AN INVITRO STUDY [J].
GUSSENHOVEN, EJ ;
ESSED, CE ;
LANCEE, CT ;
MASTIK, F ;
FRIETMAN, P ;
VANEGMOND, FC ;
REIBER, J ;
BOSCH, H ;
VANURK, H ;
ROELANDT, J ;
BOM, N .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (04) :947-952
[4]   BALLOON ANGIOPLASTY OF COARCTATION OF THE AORTA EVALUATED WITH INTRAVASCULAR ULTRASOUND IMAGING [J].
HARRISON, JK ;
SHEIKH, KH ;
DAVIDSON, CJ ;
KISSLO, KB ;
LEITHE, ME ;
HIMMELSTEIN, SI ;
KANTER, RJ ;
BASHORE, TM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) :906-909
[5]   COMPARISON OF COMPLICATIONS DURING PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY FROM 1977 TO 1981 AND FROM 1985 TO 1986 - THE NATIONAL-HEART-LUNG-AND-BLOOD-INSTITUTE PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY REGISTRY [J].
HOLMES, DR ;
HOLUBKOV, R ;
VLIETSTRA, RE ;
KELSEY, SF ;
REEDER, GS ;
DORROS, G ;
WILLIAMS, DO ;
COWLEY, MJ ;
FAXON, DP ;
KENT, KM ;
BENTIVOGLIO, LG ;
DETRE, K .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 12 (05) :1149-1155
[6]   AUTOMATED QUANTITATIVE CORONARY ARTERIOGRAPHY - MORPHOLOGICAL AND PHYSIOLOGICAL VALIDATION IN VIVO OF A RAPID DIGITAL ANGIOGRAPHIC METHOD [J].
MANCINI, GBJ ;
SIMON, SB ;
MCGILLEM, MJ ;
LEFREE, MT ;
FRIEDMAN, HZ ;
VOGEL, RA .
CIRCULATION, 1987, 75 (02) :452-460
[7]   POLYTETRAFLUOROETHYLENE GRAFT-SURVIVAL IN HEMODIALYSIS [J].
MUNDA, R ;
FIRST, MR ;
ALEXANDER, JW ;
LINNEMANN, CC ;
FIDLER, JP ;
KITTUR, D .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1983, 249 (02) :219-222
[8]   VASCULAR ACCESS FOR HEMODIALYSIS - PATENCY RATES AND RESULTS OF REVISION [J].
PALDER, SB ;
KIRKMAN, RL ;
WHITTEMORE, AD ;
HAKIM, RM ;
LAZARUS, JM ;
TILNEY, NL .
ANNALS OF SURGERY, 1985, 202 (02) :235-239
[9]   INTRACARDIAC, INTRAVASCULAR, 2-DIMENSIONAL, HIGH-FREQUENCY ULTRASOUND IMAGING OF PULMONARY-ARTERY AND ITS BRANCHES IN HUMANS AND ANIMALS [J].
PANDIAN, NG ;
WEINTRAUB, A ;
KREIS, A ;
SCHWARTZ, SL ;
KONSTAM, MA ;
SALEM, DN .
CIRCULATION, 1990, 81 (06) :2007-2012
[10]   DETECTION OF INTRAARTERIAL THROMBUS BY INTRAVASCULAR HIGH-FREQUENCY 2-DIMENSIONAL ULTRASOUND IMAGING INVITRO AND INVIVO STUDIES [J].
PANDIAN, NG ;
KREIS, A ;
BROCKWAY, B .
AMERICAN JOURNAL OF CARDIOLOGY, 1990, 65 (18) :1280-1283