The humidity buffering potential of stabilised rammed earth materials is investigated based on the moisture buffer value concept. The moisture buffer value is (a) measured experimentally, (b) calculated from an analytical solution of the mass transfer and (c) simulated using a numerical solution of the combined heat and mass transfer. The numerical solution to the equations is described, as well as the modelling tool termed 'CHAMP' (coupled heat and mass transport in porous media). The results show that stabilised rammed earth can be a 'good' moisture buffering material under the Nordtest classification scheme. They also show that the moisture buffer value of stabilised rammed earth materials could be optimised or maximised by controlling the grading and mineralogy of the sub-soil and the manufacturing techniques. Sensitivity analysis of the moisture buffer value to the moisture transfer resistance at the surface is explored through numerical simulation and the need to control the experimental measurement carefully is explored.
引用
收藏
页码:335 / 344
页数:10
相关论文
共 19 条
[1]   Hygrothermal analysis of a stabilised rammed earth test building in the UK [J].
Allinson, David ;
Hall, Matthew .
ENERGY AND BUILDINGS, 2010, 42 (06) :845-852
[2]  
BSI, 2007, 15026 BSI EN
[3]  
BSI, 1990, 13774 BSI EN
[4]  
CIBSE (Chartered Institute of Building Service Engineers), 2006, CIBSE GUID DES DAT
[5]   Impact of temperature and humidity on perception of indoor air quality during immediate and longer whole-body exposures [J].
Fang, L ;
Clausen, G ;
Fanger, PO .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1998, 8 (04) :276-284
[6]   Impact of temperature and humidity on the perception of indoor air quality [J].
Fang, L ;
Clausen, G ;
Fanger, PO .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1998, 8 (02) :80-90
[7]   Rammed earth sample production: context, recommendations and consistency [J].
Hall, M ;
Djerbib, Y .
CONSTRUCTION AND BUILDING MATERIALS, 2004, 18 (04) :281-286
[8]   Analysis of the hygrothermal functional properties of stabilised rammed earth materials [J].
Hall, Matthew ;
Allinson, David .
BUILDING AND ENVIRONMENT, 2009, 44 (09) :1935-1942
[9]  
Howieson S, 2003, BUILD SERV ENG RES T, V24, P137, DOI DOI 10.1191/0143624403BT067OA
[10]   Potential effects of permeable and hygroscopic lightweight structures on thermal comfort and perceived IAQ in a cold climate [J].
Kurnitski, J. ;
Kalamees, T. ;
Palonen, J. ;
Eskola, L. ;
Seppaenen, O. .
INDOOR AIR, 2007, 17 (01) :37-49