Optically stimulated luminescent dosimetry for high dose rate brachytherapy

被引:15
作者
Tien, Christopher Jason [1 ]
Ebeling, Robert, III [1 ]
Hiatt, Jessica R. [1 ]
Curran, Bruce [1 ]
Sternick, Edward [1 ]
机构
[1] Rhode Isl Hosp, Dept Radiat Oncol, 593 Eddy St, Providence, RI 02903 USA
来源
FRONTIERS IN ONCOLOGY | 2012年 / 2卷
关键词
Accuboost; brachytherapy; dosimetry; high dose rate brachytherapy; iridium; 192; kilovottage dosimetry; nanodot; optically stimulated luminescent detectors;
D O I
10.3389/fonc.2012.00091
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The objective was to determine whether optically stimulated luminescent dosimeters (OSLDs) were appropriate for in vivo measurements in high dose rate brachytherapy. In order to make this distinction, three dosimetric characteristics were tested: dose linearity, dose rate dependence, and angular dependence. The Landauer nanoDotTM' OSLDs were chosen due to their popularity and their availability commercially. Methods: To test the dose linearity, each OSLD was placed at a constant location and the dwell time was varied. Next, in order to test the dose rate dependence, each OSLD was placed at different OLSD-to-source distances and the dwell time was held constant. A curved geometry was created using a circular Accuboost applicator in order to test angular dependence. Results: The OSLD response remained linear for high doses and was independent of dose rate. For doses up to 600 cGy, the linear coefficient of determination was 0.9988 with a response of 725 counts per cGy. The angular dependence was significant only in "edge-on" scenarios. Conclusion: OSLDs are conveniently read out using commercially available readers. OSLDs can be re-read and serve as a permanent record for clinical records or be annealed using conventional fluorescent light. Lastly, OSLDs are produced commercially for $5 each. Due to these convenient features, in conjunction with the dosimetric performance, OSLDs should be considered a clinically feasible and attractive tool for in vivo HDR brachytherapy measurements.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 29 条
[1]   Optically stimulated luminescence response of Al2O3 to beta radiation [J].
Akselrod, A ;
Akselrod, MS ;
Larsen, NA ;
Banerjee, D ;
Botter-Jensen, L ;
Christensen, P ;
Lucas, AC ;
McKeever, SWS ;
Yoder, RC .
RADIATION PROTECTION DOSIMETRY, 1999, 85 (1-4) :125-128
[2]  
AKSELROD MS, 1990, RADIAT PROT DOSIM, V32, P15
[3]   UNCERTAINTIES ASSOCIATED WITH THE USE OF OPTICALLY STIMULATED LUMINESCENCE IN PERSONAL DOSIMETRY [J].
Benevides, L. ;
Romanyukha, A. ;
Hull, F. ;
Duffy, M. ;
Voss, S. ;
Moscovitch, M. .
RADIATION PROTECTION DOSIMETRY, 2011, 144 (1-4) :165-167
[4]   Monte Carlo-aided dosimetry of a new high dose-rate brachytherapy source [J].
Daskalov, GM ;
Loffler, E ;
Williamson, JF .
MEDICAL PHYSICS, 1998, 25 (11) :2200-2208
[5]   A dosimetric uncertainty analysis for photon-emitting brachytherapy sources: Report of AAPM Task Group No. 138 and GEC-ESTRO [J].
DeWerd, Larry A. ;
Ibbott, Geoffrey S. ;
Meigooni, Ali S. ;
Mitch, Michael G. ;
Rivard, Mark J. ;
Stump, Kurt E. ;
Thomadsen, Bruce R. ;
Venselaar, Jack L. M. .
MEDICAL PHYSICS, 2011, 38 (02) :782-801
[6]   Characterization of optically stimulated luminescent dosimeters, OSLDs, for clinical dosimetric measurements [J].
Jursinic, Paul A. .
MEDICAL PHYSICS, 2007, 34 (12) :4594-4604
[7]   Changes in optically stimulated luminescent dosimeter (OSLD) dosimetric characteristics with accumulated dose [J].
Jursinic, Paul A. .
MEDICAL PHYSICS, 2010, 37 (01) :132-140
[8]   Angular dependence of the nanoDot OSL dosimeter [J].
Kerns, James R. ;
Kry, Stephen F. ;
Sahoo, Narayan ;
Followill, David S. ;
Ibbott, Geoffrey S. .
MEDICAL PHYSICS, 2011, 38 (07) :3955-3962
[9]  
Khan F.M., 2003, PHYS RAD THERAPY, V3rd ed
[10]  
Kim D. W., 2011, RADIAT PROT DOSIM, V145, P1