Failure Analysis and Remaining Life Assessment of Methanol Reformer Tubes

被引:5
|
作者
Quickel, G. [1 ]
Jaske, C. [1 ]
Rollins, B. [1 ]
Beavers, J. [1 ]
机构
[1] DNV Columbus Inc, Dublin, OH 43017 USA
关键词
Reformer; Methanol; Failure; Creep; Remaining;
D O I
10.1007/s11668-009-9294-2
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
High-quality failure analysis and good engineering judgment can turn plant shutdowns resulting from methanol reformer tube failures into an opportunity to improve the future performance of the reformer furnace. The plant down time can be used to evaluate remaining tube life and provide some insight into the effect of tube operating history, especially tube metal temperature on tube performance. The results can be used to minimize potential future failures and economic losses because of reformer shutdowns. In this article, the failure mechanism of a ruptured reformer tube is determined and an assessment of the remaining life of non-ruptured tubes in the reformer is discussed. Two assessment methods are reviewed (1) metallographic examination of ex-service material to characterize microstructure and creep damage and (2) modeling of creep damage accumulation using special-purpose finite-element software (WinTUBE (TM)).
引用
收藏
页码:511 / 516
页数:6
相关论文
共 50 条
  • [1] Failure analysis and remaining life assessment of service exposed primary reformer heater tubes
    Swarninathan, Jaganathan
    Guguloth, Krishna
    Gunjan, Manojkurnar
    Roy, Prabirkumar
    Ghosh, Rabindranath
    ENGINEERING FAILURE ANALYSIS, 2008, 15 (04) : 311 - 331
  • [2] Failure analysis and creep remaining life of hydrogen reformer outlet pigtail tubes
    Maharaj, Chris
    Imbert, Clement A. C.
    Dear, John
    ENGINEERING FAILURE ANALYSIS, 2008, 15 (08) : 1076 - 1087
  • [3] Failure Probability and Remaining Life Assessment of Reheater Tubes
    Poursaeidi, E.
    Moharrami, A.
    Amini, M.
    INTERNATIONAL JOURNAL OF ENGINEERING, 2013, 26 (05): : 543 - 552
  • [4] Remaining life evaluation of reformer furnace catalyst tubes
    Bagagli, R. P.
    Ventorin, A.
    Secolin, H.
    MATERIA-RIO DE JANEIRO, 2012, 17 (03): : 1074 - 1083
  • [5] Failure analysis of reformer tubes
    Al-Shahrani S.
    Al-Meshari A.
    Rabie M.
    Journal of Failure Analysis and Prevention, 2013, 13 (6) : 731 - 736
  • [6] Criteria for the evaluation of damage and remaining life in reformer furnace tubes
    LeMay, I
    daSilveira, TL
    Vianna, CH
    INTERNATIONAL JOURNAL OF PRESSURE VESSELS AND PIPING, 1996, 66 (1-3) : 233 - 241
  • [7] Failure analysis of catalytic steam reformer tubes
    Tawancy, HM
    Ul-Hamid, A
    Mohammed, AI
    Abbas, NM
    ANTI-CORROSION METHODS AND MATERIALS, 2005, 52 (06) : 337 - 344
  • [8] Performance and Life Assessment of Reformer Tubes in Petrochemical Industries
    Raj, A.
    Goswami, B.
    Kumar, S. B.
    Krishna, G.
    Roy, N.
    Ray, A. K.
    HIGH TEMPERATURE MATERIALS AND PROCESSES, 2014, 33 (03) : 217 - 230
  • [9] Optimizing Reformer Tube Life through Advanced Inspection and Remaining Life Assessment
    Shannon, B. E.
    Jaske, C. E.
    Smith, M. C.
    PROCESS SAFETY PROGRESS, 2010, 29 (04) : 299 - 304
  • [10] Optimising reformer tube life by applying advanced inspection and remaining life assessment technology
    Shannon, B. E.
    Jaske, C. E.
    INSIGHT, 2009, 51 (04) : 207 - 211