DIGITAL X-RAY-DETECTOR BASED ON A CCD MATRIX

被引:0
|
作者
BATYUNIN, AV
BULATOV, AN
ZAITSEV, VI
LUZIN, YN
OVCHINNIKOV, AN
PEREVEDENTSEV, VN
机构
关键词
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The application of charge-coupled devices (CCD) as position-sensitive detectors for X-ray radiation is discussed. The experimental scheme contains a videotransmission camera to detect pulsed X-ray radiation and Vektor analog-to-digital converters and computer interface. It is shown that the sensitivity range of a K1200TsM1 matrix to bremsstrahlung with an average energy of 75 keV is 2.7 . 10(-8)-0.8 . 10(-6) J/cm2. The spatial resolution of the resultant X-ray image is discussed.
引用
收藏
页码:689 / 692
页数:4
相关论文
共 50 条
  • [41] A SIMPLE CHARGED-PARTICLE-DISCRIMINATING X-RAY-DETECTOR
    FIORUCCI, G
    BOVET, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 239 (03): : 635 - 638
  • [42] A NOVEL TRITIUM PROCESS MONITOR THAT USES AN X-RAY-DETECTOR
    SURETTE, RA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 337 (2-3): : 588 - 593
  • [43] A COMPUTER-CONTROLLED ONE-DIMENSION X-RAY-DETECTOR
    VASILEV, SE
    DONETS, DE
    ZANEVSKY, YV
    IVANOV, AB
    SMYKOV, LP
    CHEREMUKHINA, GA
    CHERNENKO, SP
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1995, 38 (02) : 261 - 265
  • [44] ONE-COORDINATE X-RAY-DETECTOR OD-2
    AULCHENKO, VM
    FELDMAN, IG
    KHABAKHPASHEV, AG
    SAVINOV, GA
    SIDOROV, VA
    USOV, YV
    YASENEV, MV
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 261 (1-2): : 78 - 81
  • [45] A VERSATILE TELEVISION X-RAY-DETECTOR AND IMAGE-PROCESSING SYSTEM
    KALATA, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 201 (01): : 35 - 41
  • [46] Soft X-ray spectrograph with CCD-Based detector
    Volkov, GS
    Zaitsev, VI
    AttelanLanglet, S
    Mishenskii, VO
    Papazyan, YV
    Fedulov, MV
    Smirnov, VP
    Etlicher, B
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1997, 40 (01) : 113 - 117
  • [47] X-ray imaging using CCD based area detector
    Sinha, A
    SOLID STATE PHYSICS, VOL 41, 1998, 1999, : 71 - 74
  • [48] Calibration of the energy response matrix for X-ray detector CCD236
    Zhu, Y. X.
    Lu, J. B.
    Li, X. B.
    Liu, X. Y.
    Cui, W. W.
    Han, D. W.
    Wang, J.
    Wang, Y. S.
    Zhao, X. F.
    Zhang, S.
    Wang, G. F.
    Chen, Y. P.
    Yu, N.
    Chen, Y.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (05)
  • [49] CHARGE COLLECTION AND THERMALIZATION IN A COMPOSITE CALORIMETRIC AND IONIZATION X-RAY-DETECTOR
    STAHLE, CK
    WOUTERS, J
    KELLEY, RL
    MOSELEY, SH
    SZYMKOWIAK, AE
    JOURNAL OF APPLIED PHYSICS, 1994, 75 (08) : 3723 - 3731
  • [50] X-RAY-DETECTOR WINDOW REVEALS THE LIGHT-ELEMENT WORLD
    ADEN, G
    ISAACS, D
    RESEARCH & DEVELOPMENT, 1987, 29 (08): : 85 - &