摘要
A reversed-phase high performance liquid chromatographic method was developed for the direct determination of bentazone in the presence of soil and some of its normal constituents (kaolinite, montmorillonite and peat). Spiked aqueous soil samples were injected after centrifugation and filtration. Quantitative recoveries were observed and good precision was obtained. The concentration range studied, 1.22-25.62 mg/l, is the most suitable for adsorption-desorption studies of bentazone on soil and soil constituents.
引用
收藏
页码:57 / 61
页数:5
相关论文
共 7 条
  • [1] Liquid chromatographic determination of methabenzthiazuron in soil aqueous solutions with photodiode-array detection
    SanchezRasero, F
    Matallo, M
    Pena, A
    delaColina, C
    Dios, GC
    Romero, E
    JOURNAL OF CHROMATOGRAPHY A, 1996, 733 (1-2) : 367 - 370
  • [2] LIQUID-CHROMATOGRAPHIC DETERMINATION OF INDAPAMIDE IN THE PRESENCE OF ITS DEGRADATION PRODUCTS
    PADVAL, MV
    BHARGAVA, HN
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (10) : 1033 - 1036
  • [3] Identification of main constituents of historical textile dyes by ultra performance liquid chromatography with photodiode array detection
    Taujenis, Lukas
    Olsauskaite, Vilma
    CHEMIJA, 2012, 23 (03): : 210 - 215
  • [4] Analysis and purification of phorbol esters using normal phase HPLC and photodiode-array detection
    Dimitrijevic, SM
    Humer, U
    Shehadeh, M
    Ryves, WJ
    Hassan, NM
    Evans, FJ
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1996, 15 (03) : 393 - 401
  • [5] Direct eicosanoid profiling of the hypoxic lung by comprehensive analysis via capillary liquid chromatography with dual online photodiode-array and tandem mass-spectrometric detection
    Ladislau Kiss
    Yasmin Röder
    Jens Bier
    Norbert Weissmann
    Werner Seeger
    Friedrich Grimminger
    Analytical and Bioanalytical Chemistry, 2008, 390 : 697 - 714
  • [6] Direct eicosanoid profiling of the hypoxic lung by comprehensive analysis via capillary liquid chromatography with dual online photodiode-array and tandem mass-spectrometric detection
    Kiss, Ladislau
    Roeder, Yasmin
    Bier, Jens
    Weissmann, Norbert
    Seeger, Werner
    Grimminger, Friedrich
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 390 (02) : 697 - 714
  • [7] EFFECT OF DRYING TEMPERATURE AND BLANCHING ON THE DEGRADATION OF CHLOROPHYLL-A AND CHLOROPHYLL-B IN MINT (MENTHA-SPICATA HUDS) AND BASIL (OCIMUM-BASILICUM) - ANALYSIS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH PHOTODIODE ARRAY DETECTION
    ROCHA, T
    MARTYAUDOUIN, C
    LEBERT, A
    CHROMATOGRAPHIA, 1993, 36 : 152 - 156