INHOMOGENEITY OF PULMONARY VENTILATION DURING SUSTAINED MICROGRAVITY AS DETERMINED BY SINGLE-BREATH WASHOUTS

被引:81
作者
GUY, HJB
PRISK, GK
ELLIOTT, AR
DEUTSCHMAN, RA
WEST, JB
机构
[1] Dept. of Medicine, University of California, San Diego, CA 92093-0931
关键词
DISTRIBUTION OF VENTILATION; ACCELERATION; AIRWAY CLOSURE; PHASE III; PHASE IV; PARABOLIC FLIGHT; SPACEFLIGHT; SPACELAB; NITROGEN WASHOUT; CONVECTION; DIFFUSION;
D O I
10.1152/jappl.1994.76.4.1719
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Gravity is known to cause inhomogeneity of ventilation. Nongravitational factors are also recognized, but their relative contribution is not understood. We therefore studied ventilatory inhomogeneity during sustained microgravity during the 9-day flight of Spacelab SLS-1. All seven crew members performed single-breath nitrogen washouts. They inspired a vital capacity breath of 100% oxygen with a bolus of argon at the start of inspiration, and the inspiratory and expiratory flow rates were controlled at 0.5 l/s. Control measurements in normal gravity (1 G) were made pre- and postflight in the standing and supine position. Compared with the standing l-G measurements, there was a marked decrease in ventilatory inhomogeneity during microgravity, as evidenced by the significant reductions in cardiogenic oscillations, slope of phase III, and height of phase IV for nitrogen and argon. However, argon phase IV volume was not reduced, and considerable ventilatory inhomogeneity remained. For example, the heights of the cardiogenic oscillations during microgravity for nitrogen and argon were 44 and 24%, respectively, of their values at 1 G, whereas the slopes of phase III for nitrogen and argon were 78 and 29%, respectively, of those at 1 G. The presence of a phase IV in microgravity is strong evidence that airway closure still occurs in the absence of gravity. The results were qualitatively similar to those found previously during short periods of 0 G in parabolic flight.
引用
收藏
页码:1719 / 1729
页数:11
相关论文
共 32 条
  • [1] AGOSTONI E, 1985, THORAX, V2, P259
  • [2] LUNG-VOLUME, VOLUME HISTORY, AND DISTRIBUTION OF INHALED BOLUSES
    ANTHONISEN, NR
    PERESS, LJ
    SIEGLER, DIM
    DHINGRA, S
    [J]. RESPIRATION PHYSIOLOGY, 1978, 33 (03): : 279 - 288
  • [3] GRAVITY-DEPENDENT SEQUENTIAL EMPTYING OF LUNG REGIONS
    ANTHONISEN, NR
    ROBERTSON, PC
    ROSS, WRD
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1970, 28 (05) : 589 - +
  • [4] CARDIOGENIC OSCILLATIONS IN EXPIRED GAS - ORIGIN AND MECHANISM
    ARIELI, R
    [J]. RESPIRATION PHYSIOLOGY, 1983, 52 (02): : 191 - 204
  • [5] EFFECT OF GRAVITY ON DISTRIBUTION OF PULMONARY VENTILATION
    BRYAN, AC
    MILICEMI.J
    PENGELLY, D
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1966, 21 (03) : 778 - &
  • [6] CONVECTION-DEPENDENT AND DIFFUSION-DEPENDENT VENTILATION MALDISTRIBUTION IN NORMAL SUBJECTS
    CRAWFORD, ABH
    MAKOWSKA, M
    PAIVA, M
    ENGEL, LA
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1985, 59 (03) : 838 - 846
  • [7] CUMMING C, 1967, RESPIR PHYSL, V2, P386
  • [8] ANALYSES OF SEQUENTIAL FILLING AND EMPTYING OF THE LUNG
    ENGEL, LA
    PAIVA, M
    [J]. RESPIRATION PHYSIOLOGY, 1981, 45 (03): : 309 - 321
  • [9] DEMONSTRATION OF AIRWAY-CLOSURE IN MAN
    ENGEL, LA
    GRASSINO, A
    ANTHONISEN, NR
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1975, 38 (06) : 1117 - 1125
  • [10] VENTILATION DISTRIBUTION IN ANATOMICAL LUNG UNITS
    ENGEL, LA
    UTZ, G
    WOOD, LDH
    MACKLEM, PT
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1974, 37 (02) : 194 - 200