THE RISK OF MIDLINE CATHETERIZATION IN HOSPITALIZED-PATIENTS - A PROSPECTIVE-STUDY

被引:46
作者
MERMEL, LA
PARENTEAU, S
TOW, SM
机构
[1] RHODE ISL HOSP, DEPT INFECT CONTROL, PROVIDENCE, RI 02903 USA
[2] RHODE ISL HOSP, DEPT NURSING, PROVIDENCE, RI 02903 USA
[3] BROWN UNIV, SCH MED, PROVIDENCE, RI USA
关键词
D O I
10.7326/0003-4819-123-11-199512010-00005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To assess the risk associated with midline catheter use in hospitalized patients. Design: Prospective, consecutive enrollment. Setting: A 719-bed university-affiliate hospital. Patients: Patients were enrolled if they were likely to require at least 7 days of intravascular catheterization while hospitalized. Measurements: Patients were monitored for adverse reactions, Catheter segment, insertion site, hub, infusate, and blood cultures were assessed. Results: From February 1993 through June 1994, 251 Landmark midline catheters were inserted in 238 patients, One hundred forty catheter cultures were obtained from 130 patients who remained hospitalized for the duration of catheterization. For these 130 patients, the mean duration of catheterization was 9 days, the incidence of catheter colonization was 5.0 per 1000 catheter days, and the incidence of catheter-related bloodstream infection was 0.8 per 1000 catheter days. During the study period, two severe, unexpected adverse reactions occurred that may have been associated with the use of Landmark midline catheters; no such reactions were associated with the insertion of 58 580 Teflon peripheral catheters (P < 0.00001; exact 95% lower bound of the odds ratio, 68.9). Fifty-three similar reactions associated with Landmark midline catheters, including two deaths, have been reported to the Food and Drug Administration through June 1994. Conclusion: The risk for midline catheter-related infection is low. However, Landmark midline catheters are associated with life-threatening adverse reactions that are probably attributable to the catheter material itself.
引用
收藏
页码:841 / 844
页数:4
相关论文
共 16 条
  • [1] Blum D Y, 1995, J Intraven Nurs, V18, P116
  • [2] ADVERSE REACTIONS TO ELASTOMERIC INTRAVENOUS CATHETERS IN ADOLESCENTS WITH CYSTIC-FIBROSIS
    BRIARS, G
    [J]. LANCET, 1993, 342 (8863) : 118 - 118
  • [3] BROSS JE, 1995, INFECT CONTROL HO S2, V16, P38
  • [4] A CONTROLLED TRIAL OF SCHEDULED REPLACEMENT OF CENTRAL VENOUS AND PULMONARY-ARTERY CATHETERS
    COBB, DK
    HIGH, KP
    SAWYER, RG
    SABLE, CA
    ADAMS, RB
    LINDLEY, DA
    PRUETT, TL
    SCHWENZER, KJ
    FARR, BM
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1992, 327 (15) : 1062 - 1068
  • [5] PREDICTIVE VALUE OF SURVEILLANCE SKIN AND HUB CULTURES IN CENTRAL VENOUS CATHETERS SEPSIS
    FAN, ST
    TEOHCHAN, CH
    LAU, KF
    CHU, KW
    KWAN, AKB
    WONG, KK
    [J]. JOURNAL OF HOSPITAL INFECTION, 1988, 12 (03) : 191 - 198
  • [6] Fontaine P J, 1991, J Intraven Nurs, V14, P91
  • [7] NEW PERIPHERALLY INSERTED MIDLINE CATHETER - A BETTER ALTERNATIVE FOR INTRAVENOUS ANTIBIOTIC-THERAPY IN PATIENTS WITH CYSTIC-FIBROSIS
    HARWOOD, IR
    GREENE, LM
    KOZAKOWSKIKOCH, JA
    RASOR, JS
    [J]. PEDIATRIC PULMONOLOGY, 1992, 12 (04) : 233 - 239
  • [8] LESSER E, 1993, CLIN RES, V41, pA604
  • [9] SEMIQUANTITATIVE CULTURE METHOD FOR IDENTIFYING INTRAVENOUS-CATHETER-RELATED INFECTION
    MAKI, DG
    WEISE, CE
    SARAFIN, HW
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1977, 296 (23) : 1305 - 1309
  • [10] MERMEL LA, 1996, IN PRESS ASS PROFESS