ACCURATE ATTENUATION CORRECTION DESPITE MOVEMENT DURING PET IMAGING

被引:0
作者
ANDERSSON, JLR
VAGNHAMMAR, BE
SCHNEIDER, H
机构
关键词
POSITRON EMISSION TOMOGRAPHY; ATTENUATION CORRECTION; IMAGE REGISTRATION;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recent methods to realign PET images are useful to correct minor changes in position due to subject movement. When using measured attenuation correction in the presence of larger subject movements, the attenuation data will not correctly represent the conditions of the emission scan and hence lead to erroneous attenuation correction. Methods: In the presence of subject movement between two emission scans (EM1 and EM2), the first scan was assumed to be correctly aligned with the transmission scan. The emission scans were reconstructed without attenuation correction and were realigned so that the transformation matrix mapping EM2 onto EM1 was found. The inverse of that matrix was used to reslice the transmission images. The resliced transmission images were forward projected to yield new attenuation data and EM2 was re-reconstructed. Finally, the image set from EM2 was resliced to match the orientation of EM1. The method was validated by phantom data and by human brain and cardiac studies. Results: Phantom data show that accurate attenuation correction can be achieved by reslicing the transmission images. In 795 region of interest measurements, the mean error after reslicing was -0.8%, the standard deviation of the error was 3.8% and the maximum error was no greater than 11.7%. Results from human brain and cardiac experiments yield similar results with a maximum error of 7.5% in 80 measurements. Conclusion: Reslicing of attenuation data with transformation parameters obtained from realignment of emission data provides an accurate and reliable method to obtain correct quantification in the presence of changes in position due to subject movement during or between PET examinations.
引用
收藏
页码:670 / 678
页数:9
相关论文
共 50 条
[31]   Feasibility of Template-Guided Attenuation Correction in Cat Brain PET Imaging [J].
Jin Su Kim ;
Jae Sung Lee ;
Min-Hyun Park ;
Kyeong Min Kim ;
Seung-Ha Oh ;
Gi Jeong Cheon ;
In Chan Song ;
Dae Hyuk Moon ;
June-Key Chung ;
Dong Soo Lee .
Molecular Imaging and Biology, 2010, 12 :250-258
[32]   Attenuation Correction for Magnetic Resonance Coils in Combined PET/MR Imaging: A Review [J].
Eldib, Mootaz ;
Bini, Jason ;
Faul, David D. ;
Oesingmann, Niels ;
Tsoumpas, Charalampos ;
Fayad, Zahi A. .
PET CLINICS, 2016, 11 (02) :151-+
[33]   Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging [J].
David Izquierdo-Garcia ;
Stephen J. Sawiak ;
Karin Knesaurek ;
Jagat Narula ;
Valentin Fuster ;
Joseph Machac ;
Zahi A. Fayad .
European Journal of Nuclear Medicine and Molecular Imaging, 2014, 41 :1574-1584
[34]   Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging [J].
Izquierdo-Garcia, David ;
Sawiak, Stephen J. ;
Knesaurek, Karin ;
Narula, Jagat ;
Fuster, Valentin ;
Machac, Joseph ;
Fayad, Zahi A. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 (08) :1574-1584
[35]   Accurate hybrid template–based and MR-based attenuation correction using UTE images for simultaneous PET/MR brain imaging applications [J].
Jakub Baran ;
Zhaolin Chen ;
Francesco Sforazzini ;
Nicholas Ferris ;
Sharna Jamadar ;
Ben Schmitt ;
David Faul ;
Nadim Jon Shah ;
Marian Cholewa ;
Gary F. Egan .
BMC Medical Imaging, 18
[36]   Attenuation correction for myocardial perfusion imaging - A comparison between SPECT and PET imaging by polar map analysis [J].
Graf, S. ;
Khorsand, A. ;
Stix, G. ;
Nekolla, S. ;
Becherer, A. ;
Kletter, K. ;
Dudczak, R. ;
Sochor, H. ;
Maurer, G. ;
Parenta, G. .
NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2006, 45 (04) :171-176
[37]   Revealing Anatomical Structures in PET to Generate CT for Attenuation Correction [J].
Pan, Yongsheng ;
Liu, Feihong ;
Jiang, Caiwen ;
Huang, Jiawei ;
Xia, Yong ;
Shen, Dinggang .
MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION, MICCAI 2023, PT X, 2023, 14229 :24-33
[38]   Interpolated average CT for cardiac PET/CT attenuation correction [J].
Mok, Greta S. P. ;
Ho, Cobie Y. T. ;
Yang, Bang-Hung ;
Wu, Tung-Hsin .
JOURNAL OF NUCLEAR CARDIOLOGY, 2016, 23 (05) :1072-1079
[39]   Evaluation of attenuation correction in PET/MRI with synthetic lesion insertion [J].
Hamdi, Mahdjoub ;
Natsuaki, Yutaka ;
Wangerin, Kristen A. ;
An, Hongyu ;
St James, Sarah ;
Kinahan, Paul E. ;
Sunderland, John J. ;
Larson, Peder E. Z. ;
Hope, Thomas A. ;
Laforest, Richard .
JOURNAL OF MEDICAL IMAGING, 2021, 8 (05)
[40]   Supplemental Transmission Aided Attenuation Correction for Quantitative Cardiac PET [J].
Park, Mi-Ae ;
Zaha, Vlad G. ;
Badawi, Ramsey D. ;
Bowen, Spencer L. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2024, 43 (03) :1125-1137