ACCURATE ATTENUATION CORRECTION DESPITE MOVEMENT DURING PET IMAGING

被引:0
作者
ANDERSSON, JLR
VAGNHAMMAR, BE
SCHNEIDER, H
机构
关键词
POSITRON EMISSION TOMOGRAPHY; ATTENUATION CORRECTION; IMAGE REGISTRATION;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recent methods to realign PET images are useful to correct minor changes in position due to subject movement. When using measured attenuation correction in the presence of larger subject movements, the attenuation data will not correctly represent the conditions of the emission scan and hence lead to erroneous attenuation correction. Methods: In the presence of subject movement between two emission scans (EM1 and EM2), the first scan was assumed to be correctly aligned with the transmission scan. The emission scans were reconstructed without attenuation correction and were realigned so that the transformation matrix mapping EM2 onto EM1 was found. The inverse of that matrix was used to reslice the transmission images. The resliced transmission images were forward projected to yield new attenuation data and EM2 was re-reconstructed. Finally, the image set from EM2 was resliced to match the orientation of EM1. The method was validated by phantom data and by human brain and cardiac studies. Results: Phantom data show that accurate attenuation correction can be achieved by reslicing the transmission images. In 795 region of interest measurements, the mean error after reslicing was -0.8%, the standard deviation of the error was 3.8% and the maximum error was no greater than 11.7%. Results from human brain and cardiac experiments yield similar results with a maximum error of 7.5% in 80 measurements. Conclusion: Reslicing of attenuation data with transformation parameters obtained from realignment of emission data provides an accurate and reliable method to obtain correct quantification in the presence of changes in position due to subject movement during or between PET examinations.
引用
收藏
页码:670 / 678
页数:9
相关论文
共 17 条
[1]  
ANDERSSON JLR, 1994, J COMPUT ASSIST TOMO, V36
[2]  
BACHARACH SL, 1993, J NUCL MED, V34, P311
[3]   DETERMINATION OF OBJECT CONTOUR FROM PROJECTIONS FOR ATTENUATION CORRECTION IN CRANIAL POSITRON EMISSION TOMOGRAPHY [J].
BERGSTROM, M ;
LITTON, J ;
ERIKSSON, L ;
BOHM, C ;
BLOMQVIST, G .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1982, 6 (02) :365-372
[4]  
BETTINARDI V, 1993, J NUCL MED, V34, P137
[5]  
EBERL S, 1993, INT CONGR SER, V1030, P419
[6]  
HOH CK, 1993, J NUCL MED, V34, P2009
[7]   A PRELIMINARY EVALUATION OF THE SCANDITRONIX PC2048-15B BRAIN SCANNER [J].
HOLTE, S ;
ERIKSSON, L ;
DAHLBOM, M .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1989, 15 (11) :719-721
[8]  
HUANG SC, 1979, J COMPUT ASSIST TOMO, V3, P804
[9]  
HUANG SC, 1981, J NUCL MED, V22, P627
[10]   PERFORMANCE-CHARACTERISTICS OF AN 8-RING WHOLE-BODY PET SCANNER [J].
KOPS, ER ;
HERZOG, H ;
SCHMID, A ;
HOLTE, S ;
FEINENDEGEN, LE .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (03) :437-445