CHARACTERIZATION OF FLOW-THROUGH ELECTRODE PROCESSES BY AC IMPEDANCE

被引:0
作者
YUH, CY
SELMAN, JR
机构
[1] IIT,DEPT CHEM ENGN,CHICAGO,IL 60616
[2] ENERGY RES CORP,DANBURY,CT 06813
关键词
D O I
10.1002/aic.690390412
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A C-impedance method has been used successfully in characterizing a packed-bed flow-through electrode system. A macrohomogeneous model was developed to simulate the effect of structural, physical and flow parameters. The relative importance of kinetics and mass transfer can be inferred from the A C-impedance analysis. Kinetic information about copper deposition in supported cupric sulfate solution has been obtained successfully using this technique.
引用
收藏
页码:636 / 646
页数:11
相关论文
共 20 条
[1]   ANALYSIS OF CONVECTIVE MASS-TRANSFER BY POTENTIAL RELAXATION .1. STEADY-STATE COPPER DEPOSITION WITH LAMINAR NATURAL-CONVECTION STIRRING [J].
ANANTHARAMAN, V ;
PINTAURO, PN ;
NANIS, L .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1989, 136 (06) :1727-1733
[2]  
[Anonymous], 2002, MODERN ELECTROCHEMIS, DOI DOI 10.1007/B114168
[3]  
Bard A. J., 2001, ELECTROCHEMICAL METH, V2nd, P50
[4]  
Bennion N.D., 1972, J APPL ELECTROCHEM, V2, P113
[5]  
Erdey-Gruz T., 1972, KINETICS ELECTRODE P
[6]   ORTHOGONAL COLLOCATION IN CHEMICAL-REACTION ENGINEERING [J].
FINLAYSON, BA .
CATALYSIS REVIEWS-SCIENCE AND ENGINEERING, 1974, 10 (01) :69-138
[7]  
Gabrielli C., 1981, 00483 SOL INSTR GROU
[8]   EVALUATION OF PORE STRUCTURE OF POROUS-ELECTRODES USING MEASUREMENTS OF IMPEDANCE [J].
KEISER, H ;
BECCU, KD ;
GUTJAHR, MA .
ELECTROCHIMICA ACTA, 1976, 21 (08) :539-543
[9]  
Levie R, 1967, ADV ELECTROCHEMISTRY, V6, P329
[10]   THE ELECTROCHEMICAL IMPEDANCE OF POROUS NICKEL ELECTRODES IN ALKALINE MEDIA .2. NONUNIFORM TRANSMISSION-LINE ANALYSIS [J].
MACDONALD, DD ;
URQUIDIMACDONALD, M ;
BHAKTA, SD ;
POUND, BG .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1991, 138 (05) :1359-1363