X-RAY DIAGNOSTIC FOR MEASUREMENT OF HOT-ELECTRON POWER LOSS

被引:3
作者
RESS, D [1 ]
RICE, BW [1 ]
HORTON, RD [1 ]
机构
[1] TRW CO INC,REDONDO BEACH,CA 90278
关键词
D O I
10.1063/1.1141828
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A significant fraction of the power lost from a confined plasma can be carried by energetic electrons. When such electrons are incident on a probe or limiting surface, they produce thick-target x rays. It is shown that a properly filtered measurement of this x-ray flux is proportional to the electron-power loss, with little dependence on the electron loss mechanism and velocity-space distribution. The diagnostic was successfully implemented to study the radial loss of hot electrons in the Tandem Mirror Experiment-Upgrade. The method provides a very fast measurement of electron loss processes, and could therefore be useful in other areas of plasma research such as magnetic confinement in tokamaks, and inertial-confinement fusion.
引用
收藏
页码:2777 / 2779
页数:3
相关论文
共 4 条
[1]   IMPROVED TANDEM MIRROR FUSION-REACTOR [J].
BALDWIN, DE ;
LOGAN, BG .
PHYSICAL REVIEW LETTERS, 1979, 43 (18) :1318-1321
[2]  
COENSGEN FH, 1980, LLLPROP172 LAWR LIV
[3]  
GRAY DE, 1972, AM I PHYSICS HDB
[4]  
RESS D, 1988, THESIS STANFORD U, P127