ONLINE COUPLING OF INVIVO MICRODIALYSIS WITH TANDEM MASS-SPECTROMETRY

被引:43
作者
DETERDING, LJ
DIX, K
BURKA, LT
TOMER, KB
机构
[1] NIEHS,MOLEC BIOPHYS LAB,POB 12233,RES TRIANGLE PK,NC 27709
[2] NIEHS,EXPTL TOXICOL BRANCH,RES TRIANGLE PK,NC 27709
关键词
D O I
10.1021/ac00045a029
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The capability of interfacing in vivo microdialysis with mass spectrometry has been demonstrated. The goal of this research was to demonstrate the feasibility of real-time analysis in biological systems using microdialysis in combination with tandem mass spectrometry (MS/MS). Microdialysis sampling was accomplished by surgically implanting a small microdialysis probe into a tissue or area of interest. Molecules diffuse through the membrane of the microdialysis probe due to concentration differences. These molecules are collected in a sample loop and analyzed by tandem mass spectrometry. Sequential injections can be made in as little as 2 min. This capability is advantageous in the study of molecules with very rapid elimination rates. Tris(2-chloroethyl) phosphate (TRCP) was used as a model compound in the development of this analytical technique. As an example of an application of the microdialysis/MS/MS technique, plasma concentration vs time curves were obtained and compared with the plasma concentration profiles obtained using conventional studies. For the microdialysis/MS/MS studies, the average slope from three animals was -0.086 min-1. In comparison, the average slope from four animals from the conventional studies was -0.035 min-1.
引用
收藏
页码:2636 / 2641
页数:6
相关论文
共 23 条
[1]   FLOW DEPENDENT CHANGES IN THE EFFECTIVE SURFACE-AREA OF MICRODIALYSIS PROBES [J].
ALEXANDER, GM ;
GROTHUSEN, JR ;
SCHWARTZMAN, RJ .
LIFE SCIENCES, 1988, 43 (07) :595-601
[2]   FAST ATOM BOMBARDMENT OF SOLIDS (FAB) - A NEW ION-SOURCE FOR MASS-SPECTROMETRY [J].
BARBER, M ;
BORDOLI, RS ;
SEDGWICK, RD ;
TYLER, AN .
JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1981, (07) :325-327
[3]  
BURKA LT, 1991, DRUG METAB DISPOS, V19, P443
[4]   ONLINE ANALYSIS OF PENICILLIN BLOOD-LEVELS IN THE LIVE RAT BY COMBINED MICRODIALYSIS FAST-ATOM BOMBARDMENT MASS-SPECTROMETRY [J].
CAPRIOLI, RM ;
LIN, SN .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1990, 87 (01) :240-243
[5]   HIGH-SENSITIVITY MASS-SPECTROMETRIC DETERMINATION OF PEPTIDES - DIRECT ANALYSIS OF AQUEOUS-SOLUTIONS [J].
CAPRIOLI, RM ;
FAN, T .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1986, 141 (03) :1058-1065
[6]   CONTINUOUS-FLOW SAMPLE PROBE FOR FAST-ATOM-BOMBARDMENT MASS-SPECTROMETRY [J].
CAPRIOLI, RM ;
FAN, T ;
COTTRELL, JS .
ANALYTICAL CHEMISTRY, 1986, 58 (14) :2949-2954
[7]  
De Wit JSM, 1988, RAPID COMMUN MASS SP, V2, P100
[8]   DIRECT COUPLING OF OPEN-TUBULAR LIQUID-CHROMATOGRAPHY WITH MASS-SPECTROMETRY [J].
DEWIT, JSM ;
PARKER, CE ;
TOMER, KB ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1987, 59 (19) :2400-2404
[9]   RAPID AND SIMPLE PROCEDURE FOR CHRONIC CANNULATION OF RAT JUGULAR VEIN [J].
HARMS, PG ;
OJEDA, SR .
JOURNAL OF APPLIED PHYSIOLOGY, 1974, 36 (03) :391-392
[10]  
HASS JR, 1984, 32ND ANN C MASS SPEC, P380