GOODNESS-OF-FIT AND LOCAL IDENTIFIABILITY OF A RECEPTOR-BINDING RADIOPHARMACOKINETIC SYSTEM

被引:21
作者
VERA, DR
SCHEIBE, PO
KROHN, KA
TRUDEAU, WL
STADALNIK, RC
机构
[1] UNIV CALIF DAVIS,SACRAMENTO MED CTR,DEPT INTERNAL MED,SACRAMENTO,CA 95817
[2] UNIV WASHINGTON,SCH MED,DEPT RADIOL,SEATTLE,WA 98195
关键词
D O I
10.1109/10.126608
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A four-state nonlinear model describing a radiopharmacokinetic system for a hepatic receptor-binding radiopharmaceutical, [Tc-99m]-galactosyl-neoglycoalbumin (TcNGA), was tested for goodness-of-fit and local identifiability using scanning data from nine healthy subjects and seven patients with severe liver disease. Based on standard deviations of liver and heart imaging data at equilibria as a measure of observational error, the reduced chi-square ranged from 0.5 to 2.6. Values above 1.2 occurred when the subject moved during the 30 min study. Relative standard errors for each parameter were: TcNGA-receptor forward binding rate constant k(b), 13-54%; extra-hepatic plasma volume V(e), 0.8-15.0%; hepatic plasma volume V(h), 0.2-6.5%; hepatic plasma flow F, 54 --> > 1000%; and receptor concentration [R]o, 0.3-13%. The highest standard errors occurred when the amount of TcNGA injected exceeded the total amount of receptor. Therefore, when TcNGA functional imaging was performed without excess patient motion and receptor saturation, the kinetic model provided data fits of low systematic error and yielded high precision estimates of receptor concentration and forward binding rate constant. In summary, optimal performance of the kinetic model occurred when the amount ot' injected TcNGA resulted in the nonlinear operation of the pharmacokinetic system.
引用
收藏
页码:356 / 367
页数:12
相关论文
共 39 条
[1]   NEW LOOK AT STATISTICAL-MODEL IDENTIFICATION [J].
AKAIKE, H .
IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 1974, AC19 (06) :716-723
[2]  
[Anonymous], 1969, DATA REDUCTION ERROR
[3]  
[Anonymous], 1986, NUMERICAL RECIPES
[4]   EXAMINATION AND ANALYSIS OF RESIDUALS [J].
ANSCOMBE, FJ ;
TUKEY, JW .
TECHNOMETRICS, 1963, 5 (02) :141-&
[5]  
BASSINGTHWAIGHT.JB, 1984, HDB PHYSL 2, V4, P549
[6]  
Beck JV., 1977, PARAMETER ESTIMATION
[7]   MAPS OF RECEPTOR-BINDING PARAMETERS IN THE HUMAN BRAIN - A KINETIC-ANALYSIS OF PET MEASUREMENTS [J].
BLOMQVIST, G ;
PAULI, S ;
FARDE, L ;
ERIKSSON, L ;
PERSSON, A ;
HALLDIN, C .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1990, 16 (4-6) :257-265
[8]  
Conn H O, 1981, Hepatology, V1, P673, DOI 10.1002/hep.1840010617
[9]  
DRAPER NR, 1981, APPLIED REGRESSION A
[10]  
ECKELMAN WC, 1978, J NUCL MED, V19, P1179