摘要
Purpose: This study compared the diagnostic accuracy of cone-beam computed tomography (CBCT) scans obtained with 2 CBCT systems with high-and low-resolution modes for the detection of root perforations in endodontically treated mandibular molars. Materials and Methods: The root canals of 72 mandibular molars were cleaned and shaped. Perforations measuring 0.2, 0.3, and 0.4 mm in diameter were created at the furcation area of 48 roots, simulating strip perforations, or on the external surfaces of 48 roots, simulating root perforations. Forty-eight roots remained intact (control group). The roots were filled using gutta-percha (Gapadent, Tianjin, China) and AH26 sealer (Dentsply Maillefer, Ballaigues, Switzerland). The CBCT scans were obtained using the NewTom 3G (QR srl, Verona, Italy) and Cranex 3D (Soredex, Helsinki, Finland) CBCT systems in high-and low-resolution modes, and were evaluated by 2 observers. The chi-square test was used to assess the nominal variables. Results: In strip perforations, the accuracies of low-and high-resolution modes were 75% and 83% for NewTom 3G and 67% and 69% for Cranex 3D. In root perforations, the accuracies of low-and high-resolution modes were 79% and 83% for NewTom 3G and was 56% and 73% for Cranex 3D. Conclusion: The accuracy of the 2 CBCT systems was different for the detection of strip and root perforations. The Cranex 3D had non-significantly higher accuracy than the NewTom 3G. In both scanners, the high-resolution mode yielded significantly higher accuracy than the low-resolution mode. The diagnostic accuracy of CBCT scans was not affected by the perforation diameter.
引用
收藏
页码:11 / 19
页数:9
相关论文
共 20 条
[1]   Intraoperative Endodontic Applications of Cone-Beam Computed Tomography [J].
Ball, Randy L. ;
Barbizam, Joao V. ;
Cohenca, Nestor .
JOURNAL OF ENDODONTICS, 2013, 39 (04) :548-557
[2]   Detection accuracy of proximal caries by phosphor plate and cone-beam computerized tomography images scanned with different resolutions [J].
Cheng, Jun-Ge ;
Zhang, Zhi-Ling ;
Wang, Xiao-Yan ;
Zhang, Zu-Yan ;
Ma, Xu-Chen ;
Li, Gang .
CLINICAL ORAL INVESTIGATIONS, 2012, 16 (04) :1015-1021
[3]   Diagnostic value of two modes of cone-beam computed tomography in evaluation of simulated external root resorption: an in vitro study [J].
Dalili, Zahra ;
Taramsari, Mehran ;
Mehr, Seyed Zoheir Mousavi ;
Salamat, Fatemeh .
IMAGING SCIENCE IN DENTISTRY, 2012, 42 (01) :19-24
[4]   Effective doses from cone beam CT investigation of the jaws [J].
Davies, J. ;
Johnson, B. ;
Drage, N. A. .
DENTOMAXILLOFACIAL RADIOLOGY, 2012, 41 (01) :30-36
[5]   Treatment outcome in endodontics: The Toronto Study-Phase 4: Initial treatment [J].
de Chevigny, Cristian ;
Dao, Thuan T. ;
Basrani, Bettina R. ;
Marquis, Vincent ;
Farzaneh, Mahsa ;
Abitbol, Sarah ;
Friedman, Sbimon .
JOURNAL OF ENDODONTICS, 2008, 34 (03) :258-263
[6]   Detection of vertical root fractures in endodontically treated teeth in the absence and in the presence of metal post by cone-beam computed tomography [J].
de Menezes, Rebeca Ferraz ;
de Araujo, Natalia Costa ;
Costa Santa Rosa, Joedy Maria ;
Macedo Carneiro, Vanda Sanderana ;
dos Santos Neto, Alexandrino Pereira ;
Costa, Vanio ;
Moreno, Lara Marques ;
Miranda, Jessica Meirinhos ;
de Albuquerque, Diana Santana ;
Albuquerque, Monica ;
dos Santos, Roberto Alves ;
Marquez de Martinez Gerbi, Marleny Elizabeth .
BMC ORAL HEALTH, 2016, 16
[7]   Comparison of cone-beam computed tomography with intraoral photostimulable phosphor imaging plate for diagnosis of endodontic complications: a simulation study [J].
Eskandarloo, Amir ;
Mirshekari, Abbas ;
Poorolajal, Jalal ;
Mohammadi, Zahed ;
Shokri, Abbas .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2012, 114 (06) :E54-E61
[8]  
Grondahl H-G, 2004, ENDOD TOP, V8, P55, DOI DOI 10.1111/J.1601-1546.2004.00082.X
[9]  
INGLE J I, 1961, Oral Surg Oral Med Oral Pathol, V14, P83, DOI 10.1016/0030-4220(61)90477-7
[10]   Assessment of Root Perforation within Simulated Internal Resorption Cavities Using Cone-beam Computed Tomography [J].
Khojastepow, Leila ;
Moazami, Fariborz ;
Babaei, Mahbod ;
Forghani, Maryam .
JOURNAL OF ENDODONTICS, 2015, 41 (09) :1520-1523