ATOMIC-ABSORPTION SPECTROMETRIC DETECTION OF BIOTIN-CYMANTRENE AS A METALLO-TRACER FOR THE AVIDIN-BIOTIN SYSTEM

被引:10
|
作者
REMY, I [1 ]
BROSSIER, P [1 ]
机构
[1] FAC PHARM DIJON,UNITE IMMUNOANAL,7 BD JEANNE ARC,F-21033 DIJON,FRANCE
关键词
AVIDIN; BIOTIN; CYMANTRENE; IMMUNOASSAY; ZEEMAN ATOMIC ABSORPTION SPECTROMETER;
D O I
10.1039/an9931801021
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Biotin-cyclopentadienylmanganese tricarbonyl (biotin-cymantrene; biotin-Cy) is proposed as a universal metallo-tracer for immunoassays. Associated with the possibility of detecting this type of label (organometallic moieties) along with different analytical procedures, this reagent appears to be a universal system with the advantages of being inexpensive, stable and directly detected (no substrate is required). The optimum conditions for detecting the organometallic label biotin-Cy with a Zeeman atomic absorption spectrometer and the affinity of biotin-Cy for the streptavidin ligand immobilized on the walls of microtitre plates, wells or tubes are described. The results obtained demonstrate the possibility of assaying a wide range of clinical parameters because the detection limit of biotin-Cy is about 1 pg per assay. Based on the competition between immobilized bovine serum albumin adsorbed on the wall and free bovine serum albumin for specific polyclonal antibodies, the streptavidin-metallo-biotin system was tested on a competitive immunoassay model and a satisfactory calibration graph was obtained.
引用
收藏
页码:1021 / 1025
页数:5
相关论文
共 14 条
  • [1] DETECTION OF ANTIBODIES AGAINST HEPATITIS-B CORE ANTIGEN USING THE AVIDIN-BIOTIN SYSTEM
    KOREC, E
    KORCOVA, J
    KONIG, J
    HLOZANEK, I
    JOURNAL OF VIROLOGICAL METHODS, 1989, 24 (03) : 321 - 325
  • [2] Highly effective protein detection for avidin-biotin system based on colloidal photonic crystals enhanced fluoroimmunoassay
    Shen, Weizhi
    Li, Mingzhu
    Xu, Liang
    Wang, Shutao
    Jiang, Lei
    Song, Yanlin
    Zhu, Daoben
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (05): : 2165 - 2170
  • [3] THE MOUSE BLOOD-BRAIN-BARRIER AND BLOOD-NERVE BARRIER FOR IGG - A TRACER STUDY BY USE OF THE AVIDIN-BIOTIN SYSTEM
    SEITZ, RJ
    HEININGER, K
    SCHWENDEMANN, G
    TOYKA, KV
    WECHSLER, W
    ACTA NEUROPATHOLOGICA, 1985, 68 (01) : 15 - 21
  • [4] A labeling, detection, and purification system based on 4-hydroxyazobenzene-2-carboxylic acid: An extension of the avidin-biotin system
    Hofstetter, H
    Morpurgo, M
    Hofstetter, O
    Bayer, EA
    Wilchek, M
    ANALYTICAL BIOCHEMISTRY, 2000, 284 (02) : 354 - 366
  • [5] Ultrasensitive detection of ferritin in human serum by Western blotting based on quantum dots-labeled avidin-biotin system
    Liu, Pingping
    Na, Na
    Liu, Tingting
    Huang, Lingyun
    He, Dacheng
    Hua, Wenhao
    Ouyang, Jin
    PROTEOMICS, 2011, 11 (17) : 3510 - 3517
  • [6] DETECTION OF ANTIBODIES TO HEPATITIS-B SURFACE-ANTIGEN (HBSAG) USING MONOCLONAL-ANTIBODY AND THE AVIDIN-BIOTIN SYSTEM
    KOREC, E
    HLOZANEK, I
    MACH, O
    STARA, J
    NEMECEK, V
    KONIG, J
    FOLIA BIOLOGICA, 1986, 32 (06) : 377 - 383
  • [7] ISOELECTRIC-FOCUSING OF MONOCLONAL IMMUNOGLOBULIN-G, IMMUNOGLOBULIN-A AND IMMUNOGLOBULIN-M FOLLOWED BY DETECTION WITH THE AVIDIN-BIOTIN SYSTEM
    CHIODI, F
    SIDEN, A
    OSBY, E
    ELECTROPHORESIS, 1985, 6 (03) : 124 - 128
  • [9] DETECTION OF MONOCLONAL FAB ANTIBODY FRAGMENTS BOUND TO LEUKOCYTE ANTIGENS - OPTIMIZATION OF THE AVIDIN-BIOTIN SYSTEM FOR QUANTITATIVE MEMBRANE-ELISA AND CELL-ELISA
    ZIERZ, R
    MONTZ, H
    BAUMGARTEN, H
    IMMUNOBIOLOGY, 1986, 173 (2-5) : 321 - 322
  • [10] Electrochemical Immunosensor for the Early Detection of Rheumatoid Arthritis Biomarker: Anti-Cyclic Citrullinated Peptide Antibody in Human Serum Based on Avidin-Biotin System
    Chinnadayyala, Somasekhar R.
    Cho, Sungbo
    SENSORS, 2021, 21 (01) : 1 - 16