BLOOD-PRESSURE MONITORING - AUTOMATED OSCILLOMETRIC DEVICES

被引:90
作者
RAMSEY, M
机构
[1] From Critikon, Inc, Tampa, 33631-3800, FL
来源
JOURNAL OF CLINICAL MONITORING | 1991年 / 7卷 / 01期
关键词
MONITORING; BLOOD PRESSURE; MEASUREMENT TECHNIQUES; EQUIPMENT; AUTOMATED OSCILLOMETRIC DEVICES;
D O I
10.1007/BF01617900
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
An understanding of the principles of blood pressure measurement with automated oscillometric devices (e.g., Dinamap) allows a user to realize the purpose and level of accuracy for which the equipment is designed. Good technique calls for various actions: (1) using a cuff of proper size (too large a cuff will generally work acceptably, but too small a cuff will yield erroneously high readings); (2) squeezing all of the residual air out of the cuff before applying it to the arm or leg; (3) wrapping the cuff snugly around the arm or leg; (4) instructing the patient to refrain from talking or moving and letting nothing press against the cuff during measurement; (5) keeping the cuff and heart at the same horizontal level. (6) When instrument malfunction is suspected, first checking the status of the patient (not the status of the instrument) to be sure that a clinical emergency is not causing the suspected "malfunction"; (7) repeating a reading several times when it is suspicious and, if necessary, modifying the measurement conditions by using, for example, different limbs or different cuffs until the question is resolved; and (8) remembering that a leak in the cuff, hoses, or connection can cause an unexpected malfunction.
引用
收藏
页码:56 / 67
页数:12
相关论文
共 51 条
[1]  
Cushing H., On routine determinations of arterial tension in operating room and clinic, The Boston Medical and Surgical Journal, 148, pp. 250-256, (1903)
[2]  
Prys-Roberts C., Arterial manometry under pressure?, Anesthesiology, 40, pp. 1-3, (1974)
[3]  
Raey M., Non-invasive automatic determination of mean arterial pressure, Med Biol Eng Comput, 17, pp. 11-18, (1979)
[4]  
Erlanger J., Studies in blood pressure estimations by indirect methods, Am J Physiol, 39, pp. 401-446, (1916)
[5]  
Geddes L.A., Direct and indirect measurement of blood pressure, (1970)
[6]  
Posey J.A., Geddes L.A., Willia H., Moore A.G., The meaning of the point of maximum oscillations in cuff pressure in the indirect measurement of blood pressure, Cardiovasc Res Cent Bull, 8, pp. 15-25, (1969)
[7]  
Geddes L.A., Moore A.G., Garner H., Et al., The indirect measurement of mean blood pressure in the horse, Southwest Veterinarian, 23, pp. 289-294, (1970)
[8]  
Cullen D.J., Interpretation of blood pressure measurements in anesthesia, Anesthesiology, 40, pp. 6-12, (1974)
[9]  
Benson H., Herd J.A., Oscillometric measurement of arterial blood pressure, Circulation, pp. 39-40, (1969)
[10]  
Ream A.K., Systolic, diastolic, mean or pulse: Which is the best measurement of arterial pressure?, Essential noninvasive monitoring in anesthesia, pp. 53-74, (1980)