Measurement of Retinal Blood Flow Using Fluorescently Labeled Red Blood Cells(1,2,3)

被引:32
作者
Kornfield, Tess E. [1 ]
Newman, Eric A. [1 ]
机构
[1] Univ Minnesota, Dept Neurosci, Minneapolis, MN 55455 USA
基金
美国国家卫生研究院;
关键词
blood flow; methods; rat; red blood cell velocity; retina;
D O I
10.1523/ENEURO.0005-15.2015
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Blood flow is a useful indicator of the metabolic state of the retina. However, accurate measurement of retinal blood flow is difficult to achieve in practice. Most existing optical techniques used for measuring blood flow require complex assumptions and calculations. We describe here a simple and direct method for calculating absolute blood flow in vessels of all sizes in the rat retina. The method relies on ultrafast confocal line scans to track the passage of fluorescently labeled red blood cells (fRBCs). The accuracy of the blood flow measurements was verified by (1) comparing blood flow calculated independently using either flux or velocity combined with diameter measurements, (2) measuring total retinal blood flow in arterioles and venules, (3) measuring blood flow at vessel branch points, and (4) measuring changes in blood flow in response to hyperoxic and hypercapnic challenge. Confocal line scans oriented parallel and diagonal to vessels were used to compute fRBC velocity and to examine velocity profiles across the width of vessels. We demonstrate that these methods provide accurate measures of absolute blood flow and velocity in retinal vessels of all sizes.
引用
收藏
页数:13
相关论文
共 88 条
[11]   Improved blood velocity measurements with a hybrid image filtering and iterative Radon transform algorithm [J].
Chhatbar, Pratik Y. ;
Kara, Prakash .
FRONTIERS IN NEUROSCIENCE, 2013, 7
[12]   Measurement of pulsatile total blood flow in the human and rat retina with ultrahigh speed spectral/Fourier domain OCT [J].
Choi, WooJhon ;
Baumann, Bernhard ;
Liu, Jonathan J. ;
Clermont, Allen C. ;
Feener, Edward P. ;
Duker, Jay S. ;
Fujimoto, James G. .
BIOMEDICAL OPTICS EXPRESS, 2012, 3 (05) :1047-1061
[13]  
Chung HS, 1999, INVEST OPHTH VIS SCI, V40, P2448
[14]   Conducted vascular responses: Communication across the capillary bed [J].
Collins, DM ;
McCullough, WT ;
Ellsworth, ML .
MICROVASCULAR RESEARCH, 1998, 56 (01) :43-53
[15]   Blood oxygenation level-dependent (BOLD) functional MRI of visual stimulation in the rat retina at 11.7 T [J].
De La Garza, Bryan H. ;
Muir, Eric R. ;
Li, Guang ;
Shih, Yen-Yu I. ;
Duong, Timothy Q. .
NMR IN BIOMEDICINE, 2011, 24 (02) :188-193
[16]   INVIVO CONFOCAL SCANNING LASER MICROSCOPY OF THE CEREBRAL MICROCIRCULATION [J].
DIRNAGL, U ;
VILLRINGER, A ;
EINHAUPL, KM .
JOURNAL OF MICROSCOPY-OXFORD, 1992, 165 :147-157
[17]   Measurement of the total retinal blood flow using dual beam Fourier-domain Doppler optical coherence tomography with orthogonal detection planes [J].
Doblhoff-Dier, Veronika ;
Schmetterer, Leopold ;
Vilser, Walthard ;
Garhoefer, Gerhard ;
Groeschl, Martin ;
Leitgeb, Rainer A. ;
Werkmeister, Rene M. .
BIOMEDICAL OPTICS EXPRESS, 2014, 5 (02) :630-642
[18]   The effect of different anesthetics on neurovascular coupling [J].
Franceschini, Maria Angela ;
Radhakrishnan, Harsha ;
Thakur, Kiran ;
Wu, Weicheng ;
Ruvinskaya, Svetlana ;
Carp, Stefan A. ;
Boas, David A. .
NEUROIMAGE, 2010, 51 (04) :1367-1377
[19]   Analysis of retinal circulation using an image-based network model of retinal vasculature [J].
Ganesan, P. ;
He, S. ;
Xu, H. .
MICROVASCULAR RESEARCH, 2010, 80 (01) :99-109
[20]   Retinal blood flow in the normal human eye using the canon laser blood flowmeter [J].
Garcia, JPS ;
Garcia, PT ;
Rosen, RB .
OPHTHALMIC RESEARCH, 2002, 34 (05) :295-299