Limb-Length Measurement in Total Hip Arthroplasty Using a Calipers Dual Pin Retractor

被引:1
作者
Takigami, Iori [1 ]
Itokazu, Mansho [1 ]
Itoh, Yoshiki [1 ]
Matsumoto, Kazu [1 ]
Yamamoto, Takatoshi [1 ]
Shimizu, Katsuji [1 ]
机构
[1] Gifu Univ, Sch Med, Dept Orthopaed Surg, 1-1 Yanagido, Gifu 5011194, Japan
来源
BULLETIN OF THE HOSPITAL FOR JOINT DISEASES | 2008年 / 66卷 / 02期
关键词
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Limb-length inequality is not uncommon after total hip arthroplasty (THA) and may cause subjective problems for patients. During THA a stable reference point must be established to determine changes in leg length. Several methods have been useful in minimizing the incidence and magnitude of this problem. The equalization of leg-length discrepancy during THA can be achieved through the use of a simple measuring device, the calipers dual pin retractor (CDPR). Materials and methods: The CDPR was developed to establish a fixed point on the pelvis that would remain constant throughout the procedure and from which the distance to the greater trochanter could be measured prior to dislocation of the hip. Limb lengths were measured in 56 patients undergoing primary THA, between 2004 and 2006. The CDPR was used in all cases. Results: The preoperative diagnoses were osteoarthritis in 44 patients, osteonecrosis in five, and rheumatoid arthritis in seven. Average postoperative limb-length inequality was 4.2 mm. None of the patients had to use shoe lifts for equalization of limb lengths or complained of limb-length inequality. Conclusion: This method of measurement is beneficial with most THA approaches, and the technique is helpful for minimizing limb-length inequality during THA.
引用
收藏
页码:107 / 110
页数:4
相关论文
共 50 条
[31]   Does the use of intraoperative measurement reduce limb length discrepancies after total hip arthroplasty? [J].
Wu, Junzhe ;
Zhuang, Xunrong ;
Lin, Chaohui ;
He, Lijiang ;
Zhang, Rongmou .
BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
[32]   Does the use of intraoperative measurement reduce limb length discrepancies after total hip arthroplasty? [J].
Junzhe Wu ;
Xunrong Zhuang ;
Chaohui Lin ;
Lijiang He ;
Rongmou Zhang .
BMC Musculoskeletal Disorders, 24
[33]   Avoiding Hip Instability and Limb Length Discrepancy After Total Hip Arthroplasty [J].
Sculco, Peter K. ;
Cottino, Umberto ;
Abdel, Matthew P. ;
Sierra, Rafael J. .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2016, 47 (02) :327-+
[34]   Intraoperative measurement of limb lengthening during total hip arthroplasty [J].
Dimitrios Vasileiou Papadopoulos ;
Panagiotis Koulouvaris ;
Georgios Charalambos Aggelidakis ;
Andreas Georgios Tsantes ;
Marios Georgios Lykissas ;
Alexandros Mavrodontidis .
Indian Journal of Orthopaedics, 2017, 51 :162-167
[35]   Intraoperative measurement of limb lengthening during total hip arthroplasty [J].
Papadopoulos, Dimitrios Vasileiou ;
Koulouvaris, Panagiotis ;
Aggelidakis, Georgios Charalambos ;
Tsantes, Andreas Georgios ;
Lykissas, Marios Georgios ;
Mavrodontidis, Alexandros .
INDIAN JOURNAL OF ORTHOPAEDICS, 2017, 51 (02) :162-167
[36]   Achieving Stability and Lower-Limb Length in Total Hip Arthroplasty [J].
Berend, Keith R. ;
Sporer, Scott M. ;
Sierra, Rafael J. ;
Glassman, Andrew H. ;
Morris, Michael J. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (16) :2737-2752
[37]   Total Hip Arthroplasty in Patients With Multifactorial Perceived Limb Length Discrepancy [J].
Haleem, Amgad M. ;
Wiley, Kevin F. ;
Kuchinad, Raul ;
Rozbruch, S. Robert .
JOURNAL OF ARTHROPLASTY, 2017, 32 (10) :3044-3051
[38]   Achieving the required medial offset and limb length in total hip arthroplasty [J].
Lakshmanan, Palaniappan ;
Ahmed, Shabhaz M. Y. ;
Hansford, Richard G. N. ;
Woodnutt, David J. .
ACTA ORTHOPAEDICA BELGICA, 2008, 74 (01) :49-53
[39]   ACCURATE DETERMINATION OF LIMB LENGTH DURING TOTAL HIP-ARTHROPLASTY [J].
MOSKOVICH, R ;
STUCHIN, S .
BULLETIN OF THE HOSPITAL FOR JOINT DISEASES ORTHOPAEDIC INSTITUTE, 1986, 46 (01) :63-67
[40]   A Novel Approach for Correcting Limb Length Discrepancy in Total Hip Arthroplasty [J].
Kezer, Murat ;
Kizilay, Yusuf Onur .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (03)