Effects of shielding the radiosensitive superficial organs of ORNL pediatric phantoms on dose reduction in computed tomography

被引:26
作者
Akhlaghi, Parisa [1 ]
Miri-Hakimabad, Hashem [1 ]
Rafat-Motavalli, Laleh [1 ]
机构
[1] Ferdowsi Univ Mashhad, Fac Sci, Dept Phys, Azadi Sq, Mashhad 917751436, Iran
关键词
Image quality; lead and bismuth; Monte Carlo simulation; superficial organs' doses;
D O I
10.4103/0971-6203.144490
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In computed tomography (CT), some superficial organs which have increased sensitivity to radiation, receive doses that are significant enough to be matter of concern. Therefore, in this study, the effects of using shields on the amount of dose reduction and image quality was investigated for pediatric imaging. Absorbed doses of breasts, eyes, thyroid and testes of a series of pediatric phantoms without and with different thickness of bismuth and lead were calculated by Monte Carlo simulation. Appropriate thicknesses of shields were chosen based on their weights, X-ray spectrum, and the amount of dose reduction. In addition, the effect of lead shield on image quality of a simple phantom was assessed quantitatively using region of interest (ROI) measurements. Considering the maximum reduction in absorbed doses and X-ray spectrum, using a lead shield with a maximum thickness of 0.4 mm would be appropriate for testes and thyroid and two other organs (which are exposed directly) should be protected with thinner shields. Moreover, the image quality assessment showed that lead was associated with significant increases in both noise and CT attenuation values, especially in the anterior of the phantom. Overall, the results suggested that shielding is a useful optimization tool in CT.
引用
收藏
页码:238 / 246
页数:9
相关论文
共 44 条
[1]   An overview of exposure parameters, dose measurements and strategies for dose reduction in pediatric CT examinations [J].
Akhlaghi, P. ;
Hakimabad, H. Miri ;
Motavalli, L. Rafat .
RADIOPROTECTION, 2014, 49 (01) :9-15
[2]  
American Association of Physicists in Medicine (AAPM), 2012, AAPM POS STAT US BIS
[3]  
[Anonymous], 2002, MCNPX US MAN VERS 2
[4]   Efficacy of breast shielding during CT of the head [J].
Brnic, Z ;
Vekic, B ;
Hebrang, A ;
Anic, P .
EUROPEAN RADIOLOGY, 2003, 13 (11) :2436-2440
[5]  
Bushberg JT, 2002, ESSENTIAL PHYS MED I, V1
[6]  
*COMM BIOL EFF LON, 2005, BEIR 7 PHAS 2, P21
[7]   Pediatric chest MDCT using tube current modulation: Effect on radiation dose with breast shielding [J].
Coursey, Courtney ;
Frush, Donald P. ;
Yoshizumi, Terry ;
Toncheva, Greta ;
Nguyen, Giao ;
Greenberg, S. Bruce .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (01) :W54-W61
[8]   Projected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007 [J].
de Gonzalez, Amy Berrington ;
Mahesh, Mahadevappa ;
Kim, Kwang-Pyo ;
Bhargavan, Mythreyi ;
Lewis, Rebecca ;
Mettler, Fred ;
Land, Charles .
ARCHIVES OF INTERNAL MEDICINE, 2009, 169 (22) :2071-2077
[9]   A Monte Carlo based method to estimate radiation dose from multidetector CT (MDCT): cylindrical and anthropomorphic phantoms [J].
DeMarco, JJ ;
Cagnon, CH ;
Cody, DD ;
Stevens, DM ;
McCollough, CH ;
O'Daniel, J ;
McNitt-Gray, MF .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (17) :3989-4004
[10]   An evaluation of in-plane shields during thoracic CT [J].
Foley, S. J. ;
McEntee, M. F. ;
Rainford, L. A. .
RADIATION PROTECTION DOSIMETRY, 2013, 155 (04) :439-450