SYSTEM 8000 - COMPUTERIZED ANTENATAL FHR ANALYSIS

被引:163
作者
DAWES, GS [1 ]
MOULDEN, M [1 ]
REDMAN, CWG [1 ]
机构
[1] JOHN RADCLIFFE HOSP,NUFFIELD DEPT OBSTET,OXFORD OX3 9DU,ENGLAND
关键词
ANTEPARTUM FETAL HEART RATE; CARDIOTOCOGRAPHY; COMPUTERIZED CTG ANALYSIS; FETAL MONITORING;
D O I
10.1515/jpme.1991.19.1-2.47
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
SYSTEM 8000 is a computerized system for antenatal fetal heart rate (FHR) analysis, with interaction online to ensure good quality recording and to minimize the time required to obtain the necessary information (based on fetal movements and tocodynamometer readings as well as FHR). The equipment consists of a Personal Computer with hard disk, interfaced to a fetal monitor. Software is written in C. An extensive definition is given on most of the functions and parameters as calculated by the system, e.g. record quality, uterine contraction peaks, basal heart rate, variation, decelerations and accelerations. System 8000 is designed to take account of the episodic changes in FHR and fetal movements characteristic of sleep states. Their presence naturally affects the mean FHR variation calculated over, say 20-30 mins. But, as the amplitude of these episodes is attenuated in association with growth retardation and hypoxaemia, the measurements of variation decline. In practice inter- and intra-observer variation is greatest in assessing FHR variation. Yet a decrease in variation is the most reliable index of fetal deterioration. The system measures FHR variation accurately and reproducibly, as well as fetal movements. In the synoptic display these two equally important fetal variables are given their rightful prominence. It has been interesting to observe how rarely the basal FHR changes in fetuses suffering progressive respiratory insufficiency, and how extreme tachycardia (a basal rate > 170/min) tends to reflect other fetal problems such as infection or maternal pyrexia.
引用
收藏
页码:47 / 51
页数:5
相关论文
共 10 条
  • [1] PATTERN OF THE NORMAL HUMAN-FETAL HEART-RATE
    DAWES, GS
    HOUGHTON, CRS
    REDMAN, CWG
    VISSER, GHA
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1982, 89 (04): : 276 - 284
  • [2] BASELINE IN HUMAN-FETAL HEART-RATE RECORDS
    DAWES, GS
    HOUGHTON, CRS
    REDMAN, CWG
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1982, 89 (04): : 270 - 275
  • [3] LIMITATIONS OF ANTENATAL FETAL HEART-RATE MONITORS
    DAWES, GS
    MOULDEN, M
    REDMAN, CWG
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1990, 162 (01) : 170 - 173
  • [4] NUMERICAL-ANALYSIS OF THE HUMAN-FETAL HEART-RATE - THE QUALITY OF ULTRASOUND RECORDS
    DAWES, GS
    VISSER, GHA
    GOODMAN, JDS
    REDMAN, CWG
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1981, 141 (01) : 43 - 52
  • [5] IMPROVEMENTS IN THE REGISTRATION AND ANALYSIS OF FETAL HEART-RATE RECORDS AT THE BEDSIDE
    DAWES, GS
    REDMAN, CWG
    SMITH, JH
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1985, 92 (04): : 317 - 325
  • [6] CHARACTERIZATION OF THE REDUCED HEART-RATE VARIATION IN GROWTH-RETARDED FETUSES
    HENSON, G
    DAWES, GS
    REDMAN, CWG
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1984, 91 (08): : 751 - 755
  • [7] ANALYSIS OF FETAL HEART-RATE ONLINE AT 32 WEEKS GESTATION
    LAWSON, GW
    DAWES, GS
    REDMAN, C
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1984, 91 (06): : 542 - 550
  • [8] LOW HUMAN-FETAL HEART-RATE VARIATION IN NORMAL-PREGNANCY
    SMITH, JH
    DAWES, GS
    REDMAN, CWG
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1987, 94 (07): : 656 - 664
  • [9] ANTENATAL FETAL HEART-RATE VARIATION IN RELATION TO THE RESPIRATORY AND METABOLIC STATUS OF THE COMPROMISED HUMAN-FETUS
    SMITH, JH
    ANAND, KJS
    COTES, PM
    DAWES, GS
    HARKNESS, RA
    HOWLETT, TA
    REES, LH
    REDMAN, CWG
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1988, 95 (10): : 980 - 989
  • [10] STREET P, 1990, UNPUB AM J OBSTET GY