Reducing Radiation Dose in Emergency CT Scans While Maintaining Equal Image Quality: Just a Promise or Reality for Severely Injured Patients?

被引:12
作者
Grupp, Ulrich [1 ]
Schaefer, Max-Ludwig [1 ]
Meyer, Henning [1 ]
Lembcke, Alexander [1 ]
Poellinger, Alexander [1 ]
Wieners, Gero [1 ]
Renz, Diane [1 ]
Schwabe, Philipp [2 ]
Streitparth, Florian [1 ]
机构
[1] Humboldt Univ, Sch Med, Charite, Dept Radiol, Augustenburger Pl 1, D-13353 Berlin, Germany
[2] Humboldt Univ, Ctr Musculoskeletal Surg, Charite, D-13353 Berlin, Germany
关键词
D O I
10.1155/2013/984645
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective. This study aims to assess the impact of adaptive statistical iterative reconstruction (ASIR) on CT imaging quality, diagnostic interpretability, and radiation dose reduction for a proven CT acquisition protocol for total body trauma. Methods. 18 patients with multiple trauma (ISS >= 16) were examined either with a routine protocol (n = 6), 30% (n = 6), or 40% (n = 6) of iterative reconstruction (IR) modification in the raw data domain of the routine protocol (140 kV, collimation: 40, noise index: 15). Study groups were matched by scan range and maximal abdominal diameter. Image noise was quantitatively measured. Image contrast, image noise, and overall interpretability were evaluated by two experienced and blinded readers. The amount of radiation dose reductions was evaluated. Results. No statistically significant differences between routine and IR protocols regarding image noise, contrast, and interpretability were present. Mean effective dose for the routine protocol was 25.3 +/- 2.9 mSv, 19.7 +/- 5.8 mSv for the IR 30, and 17.5 +/- 4.2 mSv for the IR 40 protocol, that is, 22.1% effective dose reduction for IR 30 (n = 0.093) and 30.8% effective dose reduction for IR 40 (n = 0.0203). Conclusions. IR does not reduce study interpretability in total body trauma protocols while providing a significant reduction in effective radiation dose.
引用
收藏
页数:7
相关论文
共 21 条
[1]  
American Association of Physicits in Medicine, 2008, 96 AM ASS PHYS MED
[2]   Low-dose CT of the lung: potential value of iterative reconstructions [J].
Baumueller, Stephan ;
Winklehner, Anna ;
Karlo, Christoph ;
Goetti, Robert ;
Flohr, Thomas ;
Russi, Erich W. ;
Frauenfelder, Thomas ;
Alkadhi, Hatem .
EUROPEAN RADIOLOGY, 2012, 22 (12) :2597-2606
[3]   Estimated radiation risks potentially associated with full-body CT screening [J].
Brenner, DJ ;
Elliston, CD .
RADIOLOGY, 2004, 232 (03) :735-738
[4]   Projected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007 [J].
de Gonzalez, Amy Berrington ;
Mahesh, Mahadevappa ;
Kim, Kwang-Pyo ;
Bhargavan, Mythreyi ;
Lewis, Rebecca ;
Mettler, Fred ;
Land, Charles .
ARCHIVES OF INTERNAL MEDICINE, 2009, 169 (22) :2071-2077
[5]   Computed tomography-old ideas and new technology [J].
Fleischmann, Dominik ;
Boas, F. Edward .
EUROPEAN RADIOLOGY, 2011, 21 (03) :510-517
[6]   Cancer risks from diagnostic radiology [J].
Hall, E. J. ;
Brenner, D. J. .
BRITISH JOURNAL OF RADIOLOGY, 2008, 81 (965) :362-378
[7]   Iterative Reconstruction Technique for Reducing Body Radiation Dose at CT: Feasibility Study [J].
Hara, Amy K. ;
Paden, Robert G. ;
Silva, Alvin C. ;
Kujak, Jennifer L. ;
Lawder, Holly J. ;
Pavlicek, William .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (03) :764-771
[8]   Effect of whole-body CT during trauma resuscitation on survival: a retrospective, multicentre study [J].
Huber-Wagner, Stefan ;
Lefering, Rolf ;
Qvick, Lars-Mikael ;
Koerner, Markus ;
Kay, Michael V. ;
Pfeifer, Klaus-Juergen ;
Reiser, Maximilian ;
Mutschler, Wolf ;
Kanz, Karl-Georg .
LANCET, 2009, 373 (9673) :1455-1461
[9]   Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements [J].
Kalender, WA ;
Wolf, H ;
Suess, C .
MEDICAL PHYSICS, 1999, 26 (11) :2248-2253
[10]   A Prospective Evaluation of Dose Reduction and Image Quality in Chest CT Using Adaptive Statistical Iterative Reconstruction [J].
Leipsic, Jonathon ;
Nguyen, Giang ;
Brown, Jaqueline ;
Sin, Don ;
Mayo, John R. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (05) :1095-1099