FINE-TUNING OF LINEAR-ACCELERATOR ACCESSORIES FOR STEREOTAXIC RADIOTHERAPY

被引:16
作者
ENGLER, MJ
CURRAN, BH
TSAI, JS
STERNICK, ES
SELLES, WD
WAZER, DE
MASON, WP
SAILOR, T
MACKIE, TR
机构
[1] UNIV WISCONSIN,CTR CLIN CANC,DEPT HUMAN ONCOL,MADISON,WI 53792
[2] TUFTS UNIV,SCH MED,DEPT RADIAT ONCOL,BOSTON,MA 02111
[3] UNIV WISCONSIN,PHYS SCI LAB,STOUGHTON,WI 53589
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1994年 / 28卷 / 04期
关键词
STEREOTAXIC RADIOTHERAPY; LINEAR ACCELERATOR; QUALITY ASSURANCE;
D O I
10.1016/0360-3016(94)90121-X
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Experience with the University of Wisconsin's stereotactic radiotherapy (SRT) accessory system was applied to build a new system, facilitate alignment of linac photon beams with a Brown-Roberts-Wells (BRW) stereotaxy, and increase the versatility and stability of the stereotaxy. Methods and Materials: High tensile strength stainless steel was used in the floor stand to increase the range of gantry rotation relative to ranges allowed by truss-mounted stands. The collimator assembly and floor stand were each fitted with two-axis gimbal and translation adjustments in addition to the floor stand's three-axis adjustments. The head ring positioning assembly was fitted with two braces to prevent the head ring from deforming with patient motion. Six MV linac photon beam characteristics were measured with a computer-controlled scanning system and a diode in water, at source to surface distances (SSD) of 80 and 100 cm, and for 13 divergent collimators ranging in diameter from 1-4 cm at 100 cm SSD. Quality assurance software was applied to screen data for questionable consistency or symmetry. Integrity of the stereotaxy was evaluated with target simulation films and repeated measurements which were part of the quality assurance of clinical treatments. A method was developed using a glass etched contact reticle to obtain average simulated target to beam center distances (deltaav) from target simulation films. Results and Conclusion: New aspects of the current system have improved the ability to fine tune and analyze stereotactic alignment. Beam characteristics met stringent output criteria and penumbral widths were the same or narrower than penumbral widths reported elsewhere. The precision of measuring deltaav was 0.1 mm, and deltaav averaged over 50 target simulation films was 0.7 +/- 0.1 mm. Results suggest that it may be useful to determine deltaav from target simulation films with the method described here.
引用
收藏
页码:1001 / 1008
页数:8
相关论文
共 22 条
  • [1] DOSE MEASUREMENTS AND CALCULATIONS OF SMALL RADIATION-FIELDS FOR 9-MV X-RAYS
    ARCOVITO, G
    PIERMATTEI, A
    DABRAMO, G
    BASSI, FA
    [J]. MEDICAL PHYSICS, 1985, 12 (06) : 779 - 784
  • [2] BJARNGARD BE, 1990, MED PHYS, V17, P794, DOI 10.1118/1.596475
  • [3] Burns J E, 1983, Br J Radiol Suppl, V17, P115
  • [4] Curran Bruce H., 1992, International Journal of Radiation Oncology Biology Physics, V24, P231
  • [5] PENUMBRAL MEASUREMENTS IN WATER FOR HIGH-ENERGY X-RAYS
    DAWSON, DJ
    SCHROEDER, NJ
    HOYA, JD
    [J]. MEDICAL PHYSICS, 1986, 13 (01) : 101 - 104
  • [6] Friedman W A, 1992, Neurosurg Clin N Am, V3, P141
  • [7] A 3-DIMENSIONAL VOLUME VISUALIZATION PACKAGE APPLIED TO STEREOTAXIC RADIOSURGERY TREATMENT PLANNING
    GEHRING, MA
    MACKIE, TR
    KUBSAD, SS
    PALIWAL, BR
    MEHTA, MP
    KINSELLA, TJ
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (02): : 491 - 500
  • [8] MEASUREMENT OF MECHANICAL ACCURACY OF ISOCENTER IN CONVENTIONAL LINEAR-ACCELERATOR-BASED RADIOSURGERY
    GIBBS, FA
    BUECHLER, D
    LEAVITT, DD
    MOELLER, JH
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (01): : 117 - 122
  • [9] CEREBRAL RADIATION SURGERY USING MOVING FIELD IRRADIATION AT A LINEAR-ACCELERATOR FACILITY
    HARTMANN, GH
    SCHLEGEL, W
    STURM, V
    KOBER, B
    PASTYR, O
    LORENZ, WJ
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1985, 11 (06): : 1185 - 1192
  • [10] MONTE-CARLO AND CONVOLUTION DOSIMETRY FOR STEREOTAXIC RADIOSURGERY
    KUBSAD, SS
    MACKIE, TR
    GEHRING, MA
    MISISCO, DJ
    PALIWAL, BR
    MEHTA, MP
    KINSELLA, TJ
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 19 (04): : 1027 - 1035