Estimating safe scaled distances for columns subjected to blast

被引:2
作者
Byfield, Michael [1 ]
Paramasivam, Sakthivel [1 ]
机构
[1] Univ Southampton, Fac Engn & Environm, Southampton, Hants, England
关键词
blast; concrete structures; dynamics;
D O I
10.1680/eacm.12.00006
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper is concerned with determining the minimum stand-off distance required to prevent column failures in reinforced concrete framed buildings. This is of interest because column failures can initiate progressive collapse, resulting in mass casualties. A technique is developed to determine the critical range at which failure will occur for a given weight of explosives and thus provide a safe scaled distance. The method is used to carry out a parametric study of a range of reinforced concrete columns of variable dimensions and strengths. The corresponding data were used to predict safe scaled distances for columns (with and without clearing). These values can be used to estimate the minimum stand- off distance required to prevent progressive collapses of buildings that may be subjected to deliberate blast loading.
引用
收藏
页码:23 / 29
页数:7
相关论文
共 21 条
[1]  
[Anonymous], 2008, 334002 UFC
[2]  
[Anonymous], 811011997 BSI BS
[3]  
Baker JF, 1948, CIVIL ENGINEER WAR, V3, P80
[4]  
BIGGS M, 1964, INTRO STRUCTURAL DYN
[5]   NUMERICAL SOLUTIONS OF SPHERICAL BLAST WAVES [J].
BRODE, HL .
JOURNAL OF APPLIED PHYSICS, 1955, 26 (06) :766-775
[6]  
BSI, 2000, 595012000 BSI BS
[7]  
Byfield M. P., 2004, STRUCTURAL ENG, V82, P31
[8]   Behavior and design of commercial multistory buildings subjected to blast [J].
Byfield, Mike P. .
JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2006, 20 (04) :324-329
[9]  
Byfield MP, 2011, J PERFORM CONSTR FAC, V26, P371
[10]  
Chopra A., 2001, DYNAMICS STRUCTURES