ON-COLUMN TRANSIENT AND COUPLED COLUMN ISOTACHOPHORETIC PRECONCENTRATION OF PROTEIN SAMPLES IN CAPILLARY ZONE ELECTROPHORESIS

被引:259
作者
FORET, F [1 ]
SZOKO, E [1 ]
KARGER, BL [1 ]
机构
[1] NORTHEASTERN UNIV,BARNETT INST,BOSTON,MA 02115
来源
JOURNAL OF CHROMATOGRAPHY | 1992年 / 608卷 / 1-2期
关键词
D O I
10.1016/0021-9673(92)87100-M
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two strategies for the isotachophoretic preconcentration of samples were evaluated using a standard protein mixture as an example. In the first, on-column transient isotachophoretic migration permits the injection of relatively large volumes of sample into a commercial instrument. Depending on the composition, 30-50% of the column length can be filled with the sample while maintaining good resolution of the sample components. When proper electrolyte compositions are selected, the conventional single-column instrument can be used for an isotachophoretic sample preconcentration of 50-fold or more without any modification. In the second strategy, a coupled-column system was examined which, in principle, provides a higher degree of freedom in the selection of capillary zone electrophoretic running conditions and the possibility of injection-of higher sample volumes. The gain in detection level is at least a factor of 1000 in the coupled-column arrangement; however, the instrumentation is more complicated.
引用
收藏
页码:3 / 12
页数:10
相关论文
共 23 条
[1]   ANALYSIS OF DILUTE PEPTIDE SAMPLES BY CAPILLARY ZONE ELECTROPHORESIS [J].
AEBERSOLD, R ;
MORRISON, HD .
JOURNAL OF CHROMATOGRAPHY, 1990, 516 (01) :79-88
[2]   ISOTACHOPHORESIS WITH 2 LEADING IONS AND MIGRATION BEHAVIOR IN CAPILLARY ZONE ELECTROPHORESIS .2. MIGRATION BEHAVIOR IN CAPILLARY ZONE ELECTROPHORESIS [J].
BECKERS, JL ;
EVERAERTS, FM .
JOURNAL OF CHROMATOGRAPHY, 1990, 508 (01) :19-26
[3]   FIELD AMPLIFIED SAMPLE INJECTION IN HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
CHIEN, RL ;
BURGI, DS .
JOURNAL OF CHROMATOGRAPHY, 1991, 559 (1-2) :141-152
[4]  
Deml M., 1988, ANAL ISOTACHOPHORESI
[5]  
DOLNIK V, 1990, J MICROCOLUMN SEP, V2, P127
[6]  
EVERAERTS FM, 1976, ISOTACHOPHORESIS
[7]   ONLINE FIBER OPTIC UV DETECTION CELL AND CONDUCTIVITY CELL FOR CAPILLARY ZONE ELECTROPHORESIS [J].
FORET, F ;
DEML, M ;
KAHLE, V ;
BOCEK, P .
ELECTROPHORESIS, 1986, 7 (09) :430-432
[8]  
FORET F, 1990, J MICROCOLUMN SEP, V2, P299
[9]   SAMPLE SELF-STACKING IN ZONE ELECTROPHORESIS - THEORETICAL DESCRIPTION OF THE ZONE ELECTROPHORETIC SEPARATION OF MINOR COMPOUNDS IN THE PRESENCE OF BULK AMOUNTS OF A SAMPLE COMPONENT WITH HIGH MOBILITY AND LIKE CHARGE [J].
GEBAUER, P ;
THORMANN, W ;
BOCEK, P .
JOURNAL OF CHROMATOGRAPHY, 1992, 608 (1-2) :47-57
[10]   THE USE OF A CONCENTRATION STEP TO COLLECT URINARY COMPONENTS SEPARATED BY CAPILLARY ELECTROPHORESIS AND FURTHER CHARACTERIZATION OF COLLECTED ANALYTES BY MASS-SPECTROMETRY [J].
GUZMAN, NA ;
TREBILCOCK, MA ;
ADVIS, JP .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1991, 14 (05) :997-1015