PULMONARY CLEARANCE OF FIBROUS AND ANGULAR SIC PARTICULATES IN THE SHEEP MODEL OF PNEUMOCONIOSIS

被引:4
作者
DUFRESNE, A
SEBASTIEN, P
PERRAULT, G
MASSE, S
BEGIN, R
机构
[1] INST RECH SANTE & SECUR TRAVAIL, MONTREAL H3A 3C2, QUEBEC, CANADA
[2] UNIV SHERBROOKE, UNITE RECH PULM, SHERBROOKE J1H 5N4, QUEBEC, CANADA
关键词
D O I
10.1093/annhyg/36.5.519
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Both angular and fibrous SiC (carborundum(R)) particulates can be emitted by SiC production operations. Carborundum pneumoconiosis is now recognized as an occupational lung disease with specific pathological features. These were previously reproduced in the sheep model of pneumoconiosis with fibrous SiC but not with angular SiC. To further document this question, the pulmonary retention in the sheep of the two morphological types was studied. Animals were injected in the tracheal lobe with equal mass (100 mg) of particulates prepared from SiC materials taken in the field. Particles were measured by analytical transmission electron microscopy in samples of bronchoalveolar lavage fluids (BAL) obtained at months 2, 4, 6 and 8 after the injection. They were also measured in samples of lung parenchyma obtained at month 8. Measurements in BAL and in lung samples both indicated a much lower retention for fibrous than for angular SiC. The retention rate in lung parenchyma at month 8 was 30 times lower for fibrous SiC. The half-life of decrease of concentrations was 3.4 times shorter for fibrous SiC. Other data in the literature support the notion that fine fibres are cleared more effectively than coarser angular particles.
引用
收藏
页码:519 / 530
页数:12
相关论文
共 29 条
[1]   SELECTIVE EXPOSURE AND ANALYSIS OF THE SHEEP TRACHEAL LOBE AS A MODEL FOR TOXICOLOGICAL STUDIES OF RESPIRABLE PARTICLES [J].
BEGIN, R ;
MASSE, S ;
ROLAPLESZCZYNSKI, M ;
DRAPEAU, G ;
DALLE, D .
ENVIRONMENTAL RESEARCH, 1985, 36 (02) :389-404
[2]   CARBORUNDUM PNEUMOCONIOSIS - FIBERS IN THE MINERAL ACTIVATE MACROPHAGES TO PRODUCE FIBROBLAST GROWTH-FACTORS AND SUSTAIN THE CHRONIC INFLAMMATORY DISEASE [J].
BEGIN, R ;
DUFRESNE, A ;
CANTIN, A ;
MASSE, S ;
SEBASTIEN, P ;
PERRAULT, G .
CHEST, 1989, 95 (04) :842-849
[3]  
BIGNON J, 1978, NBS SPEC PUBL, V506, P95
[4]   PULMONARY DISTRIBUTION OF PARTICLES GIVEN BY INTRATRACHEAL INSTILLATION OR BY AEROSOL INHALATION [J].
BRAIN, JD ;
KNUDSON, DE ;
SOROKIN, SP ;
DAVIS, MA .
ENVIRONMENTAL RESEARCH, 1976, 11 (01) :13-33
[5]  
BRODY AR, 1983, AM REV RESPIR DIS, V128, P724
[6]  
CAMNER P, 1980, EUR J RESPIR DIS, V61, P59
[7]   RAPID SHORT-TERM CLEARANCE OF CHRYSOTILE COMPARED WITH AMOSITE ASBESTOS IN THE GUINEA-PIG [J].
CHURG, A ;
WRIGHT, JL ;
GILKS, B ;
DEPAOLI, L .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1989, 139 (04) :885-890
[8]   EVALUATION OF OCCUPATIONAL EXPOSURE TO MIXED DUSTS AND POLYCYCLIC AROMATIC-HYDROCARBONS IN SILICON-CARBIDE PLANTS [J].
DUFRESNE, A ;
LESAGE, J ;
PERRAULT, G .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1987, 48 (02) :160-166
[9]  
DUFRESNE A, 1987, AM IND HYG ASSOC J, V48, P718, DOI 10.1202/0002-8894(1987)048<0718:MASCOP>2.0.CO
[10]  
2