SEPARATION OF METALLOTHIONEIN ISOFORMS BY CAPILLARY ZONE ELECTROPHORESIS

被引:61
|
作者
BEATTIE, JH
RICHARDS, MP
SELF, R
机构
[1] USDA ARS, BELTSVILLE AGR RES CTR, NONRUMINANT ANIM NUTR LAB, BELTSVILLE, MD 20705 USA
[2] ROWETT RES INST, DIV SERV, BUCKSBURN AB2 9SB, ABERDEEN, SCOTLAND
来源
JOURNAL OF CHROMATOGRAPHY | 1993年 / 632卷 / 1-2期
关键词
D O I
10.1016/0021-9673(93)80035-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The potential of capillary zone electrophoresis (CZE) for the analysis of metallothionein (MT) isoforms was investigated. CZE was performed using two different systems, (1) a laboratory-constructed instrument with an ISCO UV detector and (2) a Waters Quanta 4000 system. Capillaries were of 75 pm I.D. x ca. 1 m in length and loading times were up to 40 s by gravity or 4 s by electrokinetic migration at 30 kV. Samples were dissolved in 10 mM Tris-HCI buffer, pH 9.1, and electrophoresis was performed at 30 kV using a 50 mM Tris-HCI, pH 9.1 running buffer. Detection was by UV absorbance at 185 or 214 nm. Purified and semipurified MT samples were analysed for qualitative assessment of purity, relative isoform abundance and separation characteristics of MT from different species. As progress towards the development of a quantitative assay, the linearity of calibration curves and simple methods of sample preparation for analysis by CZE were investigated. Complete separation of a mixture of the two major MT isoforms was achieved in less than 5 min and the technique was found to be very useful for qualitative analysis of MT. Using a rabbit liver MT standard (500 mug/ml-1), a linear relationship was found between the gravity load time and the integrated peak area. Standard calibration curves were also linear and the detection limit for both CZE instruments under our separation conditions was 1-10 mug MT ml-1. The successful use of two solvent ''traction procedures for tissue samples demonstrated the potential of CZE for routine quantitative analysis of MT.
引用
收藏
页码:127 / 135
页数:9
相关论文
共 50 条
  • [1] APPLICATION OF CAPILLARY ZONE ELECTROPHORESIS TO THE SEPARATION OF METALLOTHIONEIN ISOFORMS
    RICHARDS, MP
    BEATTIE, JH
    SELF, R
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1993, 16 (9-10): : 2113 - 2128
  • [2] APPLICATION OF CAPILLARY ZONE ELECTROPHORESIS (CZE) TO THE SEPARATION OF METALLOTHIONEIN ISOFORMS
    RICHARDS, MP
    BEATTIE, JH
    SELF, R
    FASEB JOURNAL, 1992, 6 (04): : A1093 - A1093
  • [3] Improved separation of metallothionein isoforms by the presence of cyclodextrin in capillary zone electrophoresis
    Wilhelmsen, TW
    Hansen, BH
    Holten, V
    Olsvik, PA
    Andersen, RA
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1051 (1-2) : 237 - 245
  • [4] Separation of metallothionein isoforms of mouse liver cytosol by capillary zone electrophoresis
    Minami, T
    Yoshita, C
    Tanaka, M
    Kubo, K
    Okabe, N
    Okazaki, Y
    TALANTA, 1998, 46 (02) : 347 - 354
  • [5] Stability of metallothionein isoforms by capillary zone electrophoresis
    Minami, T
    Sakita, Y
    Kub, K
    Okabe, N
    Okazaki, Y
    Tohno, S
    Tohno, Y
    Yamada, M
    CELLULAR AND MOLECULAR BIOLOGY, 1998, 44 (02) : 285 - 292
  • [6] APPLICATION OF A POLYAMINE-COATED CAPILLARY TO THE SEPARATION OF METALLOTHIONEIN ISOFORMS BY CAPILLARY ZONE ELECTROPHORESIS
    RICHARDS, MP
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1994, 657 (02): : 345 - 355
  • [7] Quantitation of metallothionein isoforms in mouse liver on capillary zone electrophoresis
    Minami, T
    Tohno, Y
    Okazaki, Y
    Kubo, K
    Otaki, N
    Kimura, M
    ANALYTICA CHIMICA ACTA, 1998, 372 (1-2) : 241 - 247
  • [8] Identification of metallothionein isoforms on capillary zone electrophoresis by adding anti-metallothionein antibody
    Kubo, K
    Sakita, Y
    Okazaki, Y
    Otaki, N
    Kimura, M
    Minami, T
    JOURNAL OF CHROMATOGRAPHY B, 1999, 736 (1-2): : 185 - 190
  • [9] Analysis of interaction between cadmium and metallothionein isoforms by capillary zone electrophoresis
    Minami, T.
    Matsubara, H.
    O-higashi, M.
    Kubo, K.
    Electrophoresis, 17 (10):
  • [10] Analysis of interaction between cadmium and metallothionein isoforms by capillary zone electrophoresis
    Minami, T
    Matsubara, H
    Ohigashi, M
    Kubo, K
    Okabe, N
    Okazaki, Y
    ELECTROPHORESIS, 1996, 17 (10) : 1602 - 1606