Changes in strain patterns after implantation of a short stem with metaphyseal anchorage compared to a standard stem: an experimental study in synthetic bone

被引:31
作者
Gronewold, Jens [1 ]
Berner, Sebastian [2 ]
Olender, Gavin [2 ]
Hurschler, Christof [2 ]
Windhagen, Henning [1 ]
von Lewinski, Gabriela [1 ]
Floerkemeier, Thilo [1 ]
机构
[1] Hannover Med Sch, Dept Orthoped Surg, Anna Von Borries Str 1-7, D-30625 Hannover, Germany
[2] Hannover Med Sch, Biomech & Biomat Lab, Hannover, Germany
关键词
short stem hip arthroplasty; standard stem hip arthroplasty; biomechanical testing; strain gauges; strain patterns;
D O I
10.4081/or.2014.5211
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Short stem hip arthroplasties with predominantly metaphyseal fixation, such as the METHA (R) stem (Aesculap, Tuttlingen, Germany), are recommended because they are presumed to allow a more physiologic load transfer and thus a reduction of stress-shielding. However, the hypothesized metaphyseal anchorage associated with the aforementioned benefits still needs to be verified. Therefore, the METHA short stem and the Bicontact (R) standard stem (Aesculap, Tuttlingen, Germany) were tested biomechanically in synthetic femora while strain gauges monitored their corresponding strain patterns. For the METHA stem, the strains in all tested locations including the region of the calcar (87% of the non-implanted femur) were similar to conditions of synthetic bone without implanted stem. The Bicontact stem showed approximately the level of strain of the non-implanted femur on the lateral and medial aspect in the proximal diaphysis of the femur. On the anterior and posterior aspect of the proximal metaphysis the strains reached averages of 78% and 87% of the non-implanted femur, respectively. This study revealed primary metaphyseal anchorage of the METHA short stem, as opposed to a metaphyseal-diaphyseal anchorage of the Bicontact stem.
引用
收藏
页码:25 / 32
页数:8
相关论文
共 34 条
[1]   Changes in proximal femoral strain after insertion of uncemented standard and customised femoral stems [J].
Aamodt, A ;
Lund-Larsen, J ;
Eine, J ;
Andersen, E ;
Benum, P ;
Husby, OS .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (06) :921-929
[2]   Hip contact forces and gait patterns from routine activities [J].
Bergmann, G ;
Deuretzbacher, G ;
Heller, M ;
Graichen, F ;
Rohlmann, A ;
Strauss, J ;
Duda, GN .
JOURNAL OF BIOMECHANICS, 2001, 34 (07) :859-871
[3]   Primary stability and strain distribution of cementless hip stems as a function of implant design [J].
Bieger, Ralf ;
Ignatius, Anita ;
Decking, Ralf ;
Claes, Lutz ;
Reichel, Heiko ;
Duerselen, Lutz .
CLINICAL BIOMECHANICS, 2012, 27 (02) :158-164
[4]   Stress shielding and stress concentration of contemporary epiphyseal hip prostheses [J].
Cristofolini, L. ;
Juszczyk, M. ;
Taddei, F. ;
Field, R. E. ;
Rushton, N. ;
Viceconti, M. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2009, 223 (H1) :27-44
[5]   Strain distribution in the proximal human femoral metaphysis [J].
Cristofolini, L. ;
Juszczyk, M. ;
Taddei, F. ;
Viceconti, M. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2009, 223 (H3) :273-288
[6]   In vitro stress shielding measurements can be affected by large errors [J].
Cristofolini, L ;
Viceconti, M .
JOURNAL OF ARTHROPLASTY, 1999, 14 (02) :215-219
[7]   Structural behaviour and strain distribution of the long bones of the human lower limbs [J].
Cristofolini, Luca ;
Conti, Giorgia ;
Juszczyk, Mateusz ;
Cremonini, Sara ;
Jan, Serge Van Sint ;
Viceconti, Marco .
JOURNAL OF BIOMECHANICS, 2010, 43 (05) :826-835
[8]   Changes in strain distribution of loaded proximal femora caused by different types of cementless femoral stems [J].
Decking, Ralf ;
Puhl, Wolfhart ;
Simon, Ulrich ;
Claes, Lutz E. .
CLINICAL BIOMECHANICS, 2006, 21 (05) :495-501
[9]   The NANOS short stem in total hip arthroplasty: a mid term follow-up [J].
Ettinger, Max ;
Ettinger, Peter ;
Lerch, Matthias ;
Radtke, Kerstin ;
Budde, Stefan ;
Ezechieli, Marco ;
Becher, Christoph ;
Thorey, Fritz .
HIP INTERNATIONAL, 2011, 21 (05) :583-586
[10]   Midterm results of "Thrust Plate" prosthesis [J].
Fink, Bernd ;
Wessel, Stephanie ;
Deuretzbacher, Georg ;
Protzen, Michael ;
Ruther, Wolfgang .
JOURNAL OF ARTHROPLASTY, 2007, 22 (05) :703-710