High-Intensity Focused Ultrasound Thermal Lesion Detection Using Entropy Imaging of Ultrasound Radio Frequency Signal Time Series

被引:14
作者
Monfared, Maryam Mohammadi [1 ]
Behnam, Hamid [1 ]
Rangraz, Parisa [2 ]
Tavakkoli, Jahan [3 ,4 ]
机构
[1] Iran Univ Sci & Technol, Sch Elect Engn, Dept Biomed Engn, Tehran 16844, Iran
[2] Islamic Azad Univ, Dept Biomed Engn, Sci & Res Branch, Tehran, Iran
[3] Ryerson Univ, Dept Phys, Toronto, ON, Canada
[4] St Michaels Hosp, Keenan Res Ctr Biomed Sci, Inst Biomed Engn Sci & Technol, Toronto, ON, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Contrast-to-speckle ratio; entropy imaging; high intensity focused ultrasound; ultrasound radio frequency time series analysis;
D O I
10.4103/JMU.JMU_3_17
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: During the past few decades, high-intensity focused ultrasound (HIFU) modality has been gaining surging interest in various therapeutic applications such as non-or minimally-invasive cancer treatment. Among other attributes, robust and real-time HIFU treatment monitoring and lesion detection have become essential issues for successful clinical acceptance of the modality. More recently, ultrasound radio frequency (RF) time series imaging has been studied by a number of researchers. Materials and Methods: The objective of this study is to investigate the applicability of entropy parameter of RF time series of ultrasound backscattered signals, a. k. a. Entropy imaging, toward HIFU thermal lesion detection. To this end, five fresh ex vivo porcine muscle tissue samples were exposed to HIFU exposures with total acoustic powers ranging from 30 to 110 Watts. The contrast-to-speckle ratio (CSR) values of the entropy images and their corresponding B-mode images of pre-, during-and post-HIFU exposure for each acoustic power were calculated. Results: The novelty of this study is the use of Entropy parameter on ultrasound RF time series for the first time. Statistically significant differences were obtained between the CSR values for the B mode and entropy images at various acoustic powers. In case of 110 Watt, a CSR value 3.4 times higher than B-mode images was accomplished using the proposed method. Furthermore, the proposed method is compared with the scaling parameter of Nakagami imaging and same data which are used in this study. Conclusion: Entropy has the potential for using as an imaging parameter for differentiating lesions in HIFU surgery.
引用
收藏
页码:24 / 30
页数:7
相关论文
共 50 条
  • [21] A Review of High-Intensity Focused Ultrasound in Urology
    Cranston, David
    Leslie, Tom
    ter Haar, Gail
    CANCERS, 2021, 13 (22)
  • [22] REAL-TIME MONITORING OF HIGH-INTENSITY FOCUSED ULTRASOUND THERMAL THERAPY USING THE MANIFOLD LEARNING METHOD
    Rangraz, Parisa
    Behnam, Hamid
    Sobhebidari, Pooya
    Tavakkoli, Jahan
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (12) : 2841 - 2850
  • [23] TEMPERATURE DEPENDENCE OF TISSUE THERMAL PARAMETERS SHOULD BE CONSIDERED IN THE THERMAL LESION PREDICTION IN HIGH-INTENSITY FOCUSED ULTRASOUND SURGERY
    Guntur, Sitaramanjaneya Reddy
    Choi, Min Joo
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2020, 46 (04) : 1001 - 1014
  • [24] Optimized Schlieren imaging for real-time visualization of high-intensity focused ultrasound waves
    Nawrath, Helena
    Holl, Andreas
    Bedarf, Lennart
    Mai, Denis
    Alfke, Heiko
    Groebner, Jens
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2024, 69 (05): : 529 - 533
  • [25] Fluorescence Imaging for Real-Time Monitoring of High-Intensity Focused Ultrasound Cardiac Ablation
    Cheri X. Deng
    Fujian Qu
    Vladimir P. Nikolski
    Yun Zhou
    Igor R. Efimov
    Annals of Biomedical Engineering, 2005, 33 : 1352 - 1359
  • [26] Fluorescence imaging for real-time monitoring of high-intensity focused ultrasound cardiac ablation
    Deng, CRX
    Qu, FJ
    Nikolski, VP
    Zhou, Y
    Efimov, IR
    ANNALS OF BIOMEDICAL ENGINEERING, 2005, 33 (10) : 1352 - 1359
  • [27] Enhancement of ultrasound contrast agent in high-intensity focused ultrasound ablation
    Luo, Wen
    Zhou, Xiaodong
    Tian, Xue
    Ren, Xialong
    Zheng, Minjuan
    Gu, Kejun
    He, Guangbin
    ADVANCES IN THERAPY, 2006, 23 (06) : 861 - 868
  • [28] Enhancement of ultrasound contrast agent in High-Intensity focused ultrasound ablation
    Wen Luo
    Xiaodong Zhou
    Xue Tian
    Xialong Ren
    Minjuan Zheng
    Kejun Gu
    Guangbin He
    Advances in Therapy, 2006, 23 : 861 - 868
  • [29] Treatment of localized prostate cancer using high-intensity focused ultrasound
    Uchida, T
    Ohkusa, H
    Nagata, Y
    Hyodo, T
    Satoh, T
    Irie, A
    BJU INTERNATIONAL, 2006, 97 (01) : 56 - 61
  • [30] In vitro ablation of cardiac valves using high-intensity focused ultrasound
    Otsuka, R
    Fujikura, K
    Hirata, K
    Pulerwitz, T
    Oe, Y
    Suzuki, T
    Sciacca, R
    Marboe, C
    Wang, J
    Burkhoff, D
    Muratore, R
    Lizzi, FL
    Homma, S
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (01) : 109 - 114