Comparison of intraocular pressure adjusted by central corneal thickness or corneal biomechanical properties as measured in glaucomatous eyes using noncontact tonometers and the Goldmann applanation tonometer

被引:11
|
作者
Yaoeda, Kiyoshi [1 ,2 ]
Fukushima, Atsushi [1 ]
Shirakashi, Motohiro [3 ]
Fukuchi, Takeo [2 ]
机构
[1] Yaoeda Eye Clin, 2-1649-1 Naga Chou, Nagaoka, Niigata 9400053, Japan
[2] Niigata Univ, Grad Sch Med & Dent Sci, Div Ophthalmol & Visual Sci, Niigata, Japan
[3] Kido Eye Clin, Niigata, Japan
来源
CLINICAL OPHTHALMOLOGY | 2016年 / 10卷
基金
日本学术振兴会;
关键词
ocular response analyzer; corneal biomechanical property; corneal hysteresis; glaucoma; intraocular pressure;
D O I
10.2147/OPTH.S106836
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the correlation coefficients between intraocular pressure (IOP) before and after adjusting for central corneal thickness (CCT) and corneal biomechanical properties. Patients and methods: A total of 218 eyes of 218 patients with primary open-angle glaucoma (mean age =71.5 years; mean spherical equivalent =-0.51 D; mean deviation determined by Humphrey visual field analyzer =-3.22 dB) were included in this study. The tIOP and tIOPCCT, which were adjusted by the CCT (with tIOP meaning IOP not adjusted by CCT, as determined using the CT-1P; and tIOPCCT meaning IOP adjusted by CCT, as determined using the CT-1P), were determined using a noncontact tonometer. The IOPg and IOPCCT, which were adjusted by CCT, and IOPcc adjusted by corneal biomechanical properties were determined using a Reichert 7CR (with IOPg meaning IOP not adjusted by CCT or corneal biomechanical properties, as determined using the Reichert 7CR; IOPCCT meaning IOP adjusted by CCT, as determined using the Reichert 7CR; and IOPcc meaning IOP adjusted by corneal biomechanical properties, as determined using the Reichert 7CR). The GT and GTCCT adjusted by CCT were determined using a Goldmann applanation tonometer (with GT meaning IOP not adjusted by CCT, as determined using the Goldmann applanation tonometer; and with GTCCT meaning IOP adjusted by CCT, as determined using the GAT). Pearson's correlation coefficients among the IOPs were calculated and compared. P-values <0.05 were considered as statistically significant. Results: The tIOP, tIOPCCT, IOPg, IOPCCT, IOPcc, GT, and GTCCT were 14.8 +/- 2.5, 15.0 +/- 2.4, 13.1 +/- 3.2, 13.3 +/- 3.1, 13.7 +/- 2.9, 13.2 +/- 2.4, and 13.4 +/- 2.3 mmHg (mean +/- standard deviation), respectively. The correlation coefficient between tIOPCCT and tIOP (r=0.979) was significantly higher than that between tIOPCCT and the other IOPs (r=0.668-0.852; P<0.001, respectively). The correlation coefficient between IOPCCT and IOPg (r=0.994) or IOPcc and IOPg (r=0.892) was significantly higher than that between IOPCCT or IOPcc and the other IOPs (r=0.669-0.740; P<0.001, respectively). The correlation coefficient between GTCCT and GT (r=0.989) was significantly higher than that between GTCCT and the other IOPs (r=0.669-0.740; P<0.001, respectively). Conclusion: The IOP adjusted by CCT or corneal biomechanical properties depends on the measurement instrument itself, rather than the adjustment methods, for eyes of patients with primary open-angle glaucoma.
引用
收藏
页码:829 / 834
页数:6
相关论文
共 50 条
  • [21] Effects of central corneal thickness, central corneal power, and axial length on intraocular pressure measurement assessed with goldmann applanation tonometry
    Oezcura, Fatih
    Aydin, Sayime
    Uzgoeren, Nevin
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2008, 52 (05) : 353 - 356
  • [22] Effect of corneal astigmatism on intraocular pressure measurement using ocular response analyzer and Goldmann applanation tonometer
    Mana Hagishima
    Kazutaka Kamiya
    Fusako Fujimura
    Tetsuya Morita
    Nobuyuki Shoji
    Kimiya Shimizu
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2010, 248 : 257 - 262
  • [23] Effect of corneal astigmatism on intraocular pressure measurement using ocular response analyzer and Goldmann applanation tonometer
    Hagishima, Mana
    Kamiya, Kazutaka
    Fujimura, Fusako
    Morita, Tetsuya
    Shoji, Nobuyuki
    Shimizu, Kimiya
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (02) : 257 - 262
  • [24] Pediatric intraocular pressure measurements: Tonometers, central corneal thickness, and anesthesia
    Fayed, Mahmoud A.
    Chen, Teresa C.
    SURVEY OF OPHTHALMOLOGY, 2019, 64 (06) : 810 - 825
  • [25] Comparison of intraocular pressure measured by ocular response analyzer and Goldmann applanation tonometer after corneal refractive surgery: a systematic review and meta-analysis
    Zhang, Hui
    Sun, Zhengtao
    Li, Lin
    Sun, Ran
    Zhang, Haixia
    BMC OPHTHALMOLOGY, 2020, 20 (01)
  • [26] Comparison of Goldmann Applanation Tonometry and Dynamic Contour Tonometry in the Measurement of Intraocular Pressure in Eyes with Different Corneal Thicknesses
    Roszkowska, A. M.
    De Grazia, L.
    Cirone, M.
    Ferreri, G.
    OPHTHALMOLOGICA, 2009, 223 (04) : 244 - 249
  • [27] COMPARISON OF INTRAOCULAR PRESSURE MEASURED WITH GOLDMANN APPLANATION TONOMETER AND NON-CONTACT AIR-PUFF TONOMETER
    Mahsud, Hidayatullah
    Saleem, Muhammad Wali
    Muhammad, Rafiq
    Saleem, Muhammad
    Ayaz, Mirqad
    GOMAL JOURNAL OF MEDICAL SCIENCES, 2016, 14 (02): : 63 - 66
  • [28] Applanation optical coherence elastography: noncontact measurement of intraocular pressure, corneal biomechanical properties, and corneal geometry with a single instrument
    Singh, Manmohan
    Han, Zhaolong
    Nair, Achuth
    Schill, Alexander
    Twa, Michael D.
    Larin, Kirill V.
    JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (02)
  • [29] Comparison of intraocular pressure measured by ocular response analyzer and Goldmann applanation tonometer after corneal refractive surgery: a systematic review and meta-analysis
    Hui Zhang
    Zhengtao Sun
    Lin Li
    Ran Sun
    Haixia Zhang
    BMC Ophthalmology, 20
  • [30] Effects of corneal thickness on intraocular pressure measured with three different tonometers
    Murase, Hiroki
    Sawada, Akira
    Mochizuki, Kiyofumi
    Yamamoto, Tetsuya
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2009, 53 (01) : 1 - 6