PHOSPHATE KINETICS DURING HIGH-FLUX HEMODIALYSIS

被引:0
作者
DESOI, CA [1 ]
UMANS, JG [1 ]
机构
[1] UNIV CHICAGO, DEPT MED,NEPHROL SECT,5841 S MARYLAND AVE,MC-5100, CHICAGO, IL 60637 USA
来源
JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY | 1993年 / 4卷 / 05期
关键词
PHOSPHORUS; CLEARANCE; HEMODIALYSIS;
D O I
暂无
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Phosphate clearance by polysulfone (PS) and cuprophane (CU) membranes and the relationship of peridialytic changes in serum phosphate with those of serum-ionized calcium, parathyroid hormone (PTH), and insulin were studied in six stable patients undergoing chronic hemodialysis (HD). Dietary phosphate intake was 25.7 mmol/day, and total dose of elemental calcium was 3.2 g/day. Patients were dialyzed for 2 to 4 h, once with each membrane. Serum phosphate levels fell precipitously during the first hour of HD with both dialyzers, from 1.42 and 1.49 mM to nadirs of 0.53 and 0.69 mM for PS and CU, respectively. Phosphate levels began to increase either late in HD or at the end of HD and, by 4 h post-HD, did not differ from predialysis values. Total mass transfer of phosphate was greater during the first hour (3.4 and 3.2 mmol for PS and CU, respectively) than during the remainder of HD (2.4 and 2.6 mmol/h). There were no significant differences in intradialytic serum phosphate changes, postdialytic phosphate rebound, or total phosphate removal between the two dialyzers. Ionized calcium increased by 0.11 mM, and PTH was suppressed to 40 to 50% of baseline values during dialysis with either membrane. Although phosphate removal continued for the duration of dialysis, serum phosphate did not continue to decrease, either reaching an apparent steady state or beginning to rebound, even during dialysis. This suggests active phosphate mobilization from a pool other than the extracellular fluid and demonstrates the inadequacy of a one-compartment model to explain these data. Further, these data do not support the regulation of intradialytic phosphate mobilization by serum PTH or insulin. The transient, but profound, intradialytic hypophosphatemia may serve as a stimulus for as-yet-uncharacterized homeostatic mechanisms.
引用
收藏
页码:1214 / 1218
页数:5
相关论文
共 50 条
  • [21] Vancomycin hemodialysis: Clearance differences between high-flux hemodialysis and on-line hemodiafiltration
    Rodriguez, Nestor
    Gomez, Miquel
    Rico, Naira
    Maria Campistol, Josep
    Maduell, Francisco
    ARTIFICIAL ORGANS, 2019, 43 (03) : 261 - 269
  • [22] Vancomycin removal during low-flux and high-flux extended daily hemodialysis in critically ill septic patients
    Petejova, Nadezda
    Martinek, Arnost
    Zahalkova, Jana
    Duricova, Jana
    Brozmanova, Hana
    Urbanek, Karel
    Grundmann, Milan
    Kacirova, Ivana
    BIOMEDICAL PAPERS-OLOMOUC, 2012, 156 (04): : 342 - 347
  • [23] TOLERANCE OF HEMODIALYSIS - A RANDOMIZED PROSPECTIVE TRIAL OF HIGH-FLUX VERSUS CONVENTIONAL HIGH-EFFICIENCY HEMODIALYSIS
    COLLINS, DM
    LAMBERT, MB
    TANNENBAUM, JS
    OLIVERIO, M
    SCHWAB, SJ
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1993, 4 (02): : 148 - 154
  • [24] Super high-flux continuous hemodialysis in septic shock: A case report
    Madelaine, Thomas
    Page, Mathieu
    Prothet, Johanne
    Ber, Charles-Eric
    Crozon, Julien
    Allaouchiche, Bernard
    Rimmele, Thomas
    NEPHROLOGIE & THERAPEUTIQUE, 2013, 9 (07): : 497 - 500
  • [25] Infective spondylodiscitis in patients on high-flux hemodialysis and on-line hemodiafiltration
    Abid, Saima
    De Silva, Shamila
    Warwicker, Paul
    Farrington, Ken
    HEMODIALYSIS INTERNATIONAL, 2008, 12 (04) : 463 - 470
  • [26] Effects of hemoperfusion plus high-flux hemodialysis in a patient with methotrexate toxicity
    Hiroyuki Sasamura
    Ukei Anazawa
    Hiroo Kumagai
    Hajime Inamoto
    Hirotaka Asakura
    Matsuhiko Hayashi
    Marasu Murai
    Takao Saruta
    Clinical and Experimental Nephrology, 1998, 2 (1) : 75 - 79
  • [27] Methotrexate Clearance by High-Flux Hemodialysis and Peritoneal Dialysis: A Case Report
    Murashima, Miho
    Adamski, Jill
    Milone, MichaelC.
    Shaw, Leslie
    Tsai, Donald E.
    Bloom, Roy D.
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2009, 53 (05) : 871 - 874
  • [28] Single-dose pharmacokinetics of teicoplanin during hemodialysis therapy using high-flux polysulfone membranes
    Thalhammer, F
    Rosenkranz, AR
    Burgmann, H
    Graninger, W
    Hollenstien, U
    Schenk, P
    ThalhammerScherrer, R
    Traindl, O
    Horl, WH
    Breyer, S
    WIENER KLINISCHE WOCHENSCHRIFT, 1997, 109 (10) : 362 - 365
  • [29] Effect of High-Flux Hemodialysis on Delayed Hepatitis B Virus Vaccination Response in Hemodialysis Patients
    He, Qiang
    Wu, Fuquan
    Zhang, Ping
    Chen, Jianghua
    POSTGRADUATE MEDICINE, 2011, 123 (03) : 150 - 152
  • [30] Comparison of high-flux hemodialysis with hemodialysis filtration in treatment of uraemic pruritus: a randomized controlled trial
    Xia Jiang
    Fen Ji
    Zhi-Wei Chen
    Qiao-Lin Huang
    International Urology and Nephrology, 2016, 48 : 1533 - 1541