DESIGN AND PERFORMANCE OF A BIOMAGNETIC MULTICHANNEL SYSTEM FOR MEG AND MCG STUDIES

被引:7
|
作者
SCHNEIDER, S
ABRAHAMFUCHS, K
机构
[1] Siemens AG, Medical Engineering Group, Erlangen
来源
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT | 1991年 / 12卷
关键词
D O I
10.1088/0143-0815/12/B/012
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Considerations which have lead to the design of the Siemens biomagnetic multichannel system are discussed. Algorithms developed for data evaluation include removal of periodic signals, averaging of sporadic events, and separation of background activity. Means are described to fuse biomagnetic locations with three-dimensional medical images.
引用
收藏
页码:87 / 93
页数:7
相关论文
共 50 条
  • [1] Biomagnetic Measurement System on Mice-Evaluation of System Performance by MCG and Application to MEG
    Nakamura, T.
    Shirai, K.
    Ono, Y.
    Kasai, N.
    Odawara, A.
    Ishiyama, A.
    7TH EUROPEAN CONFERENCE ON APPLIED SUPERCONDUCTIVITY (EUCAS'05), 2006, 43 : 1219 - 1222
  • [2] EXPERIENCE WITH A MULTICHANNEL SYSTEM FOR BIOMAGNETIC STUDY
    SCHNEIDER, S
    ABRAHAMFUCHS, K
    REICHENBERGER, H
    SEIFERT, H
    HOENIG, HE
    ROHRLEIN, G
    PHYSIOLOGICAL MEASUREMENT, 1993, 14 : A55 - A60
  • [3] MAGNETOCARDIOGRAPHY - CLINICAL INVESTIGATIONS WITH A BIOMAGNETIC MULTICHANNEL SYSTEM
    ACHENBACH, S
    MOSHAGE, W
    PHYSIOLOGICAL MEASUREMENT, 1993, 14 : A61 - A68
  • [4] DESIGN AND FABRICATION OF MULTICHANNEL DC SQUIDS FOR BIOMAGNETIC APPLICATIONS
    Yamasaki, S.
    Morooka, T.
    Matsuda, N.
    Kawai, J.
    Mizutani, N.
    Tsukada, K.
    Uehara, G.
    Kado, H.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1993, 3 (01) : 1887 - 1889
  • [5] Development of Multichannel MEG System at IGCAR
    Mariyappa, N.
    Parasakthi, C.
    Gireesan, K.
    Sengottuvel, S.
    Patel, Rajesh
    Janawadkar, M. P.
    Radhakrishnan, T. S.
    Sundar, C. S.
    SOLID STATE PHYSICS, VOL 57, 2013, 1512 : 1152 - 1153
  • [6] MULTICHANNEL MEG STUDIES OF HUMAN COGNITIVE FUNCTIONS
    SAMS, M
    BIOMEDICAL RESEARCH-TOKYO, 1992, 13 : 57 - 60
  • [7] EXPERIENCES IN DATA-ANALYSIS AND MODELING WITH A MULTICHANNEL BIOMAGNETIC SYSTEM
    GRAUMANN, R
    BOEMMEL, F
    SCHNEIDER, S
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1991, 12 : 33 - 36
  • [8] MULTICHANNEL BIOMAGNETIC SYSTEM FOR STUDY OF ELECTRICAL-ACTIVITY IN THE BRAIN AND HEART
    SCHNEIDER, S
    HOENIG, E
    REICHENBERGER, H
    ABRAHAMFUCHS, K
    MOSHAGE, W
    OPPELT, A
    STEFAN, H
    WEIKL, A
    WIRTH, A
    RADIOLOGY, 1990, 176 (03) : 825 - 830
  • [9] Development of an MCG/MEG system for small animals and its noise reduction method
    Miyamoto, Masakazu
    Kawai, Jun
    Adachi, Yoshiaki
    Haruta, Yasuhiro
    Komamura, Kazuo
    Uehara, Gen
    8TH EUROPEAN CONFERENCE ON APPLIED SUPERCONDUCTIVITY (EUCAS'07), 2008, 97
  • [10] MAGNETOCARDIOGRAPHY - 1ST CLINICAL-RESULTS WITH A BIOMAGNETIC MULTICHANNEL SYSTEM
    MOSHAGE, W
    WEIKL, A
    ABRAHAMFUCHS, K
    SCHNEIDER, S
    GOHL, K
    FEISTEL, H
    BACHMANN, K
    WOLF, F
    HERZ KREISLAUF, 1990, 22 (07): : 245 - 249