Automatic generation of smart earthquake-resistant building system: Hybrid system of base-isolation and building-connection

被引:21
作者
Kasagi, M. [1 ]
Fujita, K. [1 ]
Tsuji, M. [1 ]
Takewaki, I [1 ]
机构
[1] Kyoto Univ, Dept Architecture & Architectural Engn, Nishikyo Ku, Kyoto 6158540, Japan
基金
日本学术振兴会;
关键词
Engineering; Building; Mechanics; Structural engineering; Civil engineering;
D O I
10.1016/j.heliyon.2016.e00069
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A base-isolated building may sometimes exhibit an undesirable large response to a long-duration, long-period earthquake ground motion and a connected building system without base-isolation may show a large response to a near-fault (rather high-frequency) earthquake ground motion. To overcome both deficiencies, a new hybrid control system of base-isolation and building-connection is proposed and investigated. In this new hybrid building system, a base-isolated building is connected to a stiffer free wall with oil dampers. It has been demonstrated in a preliminary research that the proposed hybrid system is effective both for near-fault (rather high-frequency) and long-duration, long-period earthquake ground motions and has sufficient redundancy and robustness for a broad range of earthquake ground motions.An automatic generation algorithm of this kind of smart structures of base-isolation and building-connection hybrid systems is presented in this paper. It is shown that, while the proposed algorithm does not work well in a building without the connecting-damper system, it works well in the proposed smart hybrid system with the connecting damper system.
引用
收藏
页数:21
相关论文
共 36 条
[1]  
Architectural Institute of Japan (AIJ), 2011, J ARCHIT BUILD SCI, V126, P73
[2]   Resonant behaviour of base-isolated high-rise buildings under long-period ground motions [J].
Ariga, T. ;
Kanno, Y. ;
Takewaki, I. .
STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2006, 15 (03) :325-338
[3]  
Ben-Haim Y, 2001, INFOMATION GAP DECIS
[4]  
Hall, 1995, EARTHQ SPECTRA, V11, P569, DOI [10.1193/1.1585828, DOI 10.1193/1.1585828]
[5]   RESPONSE OF HIGHRISE AND BASE-ISOLATED BUILDINGS TO A HYPOTHETICAL M(W)7.0 BLIND THRUST EARTHQUAKE [J].
HEATON, TH ;
HALL, JF ;
WALD, DJ ;
HALLING, MW .
SCIENCE, 1995, 267 (5195) :206-211
[6]   Bound of aspect ratio of base-isolated buildings considering nonlinear tensile behavior of rubber bearing [J].
Hino, J. ;
Yoshitomi, S. ;
Tsuji, M. ;
Takewaki, I. .
STRUCTURAL ENGINEERING AND MECHANICS, 2008, 30 (03) :351-368
[7]  
IRIKURA K, 2004, ANN C SEISM SOC JAP
[8]  
Jangid R.S., 1995, AUST CIVIL ENG T, V37, P325
[9]  
Jangid R.S., 1998, EARTHQ SPECTRA, V14, P95, DOI [10.1193/1.1585990, DOI 10.1193/1.1585990]
[10]   Base isolation for near-fault motions [J].
Jangid, RS ;
Kelly, JM .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2001, 30 (05) :691-707