The Alterations of the Anterior Chamber Parameters Measured with Pentacam with Age in Healthy Subjects

被引:0
作者
Emre, Sinan [1 ]
Koc, Bekir [1 ]
Doganay, Selim [1 ]
Yologlu, Saim [2 ]
机构
[1] Inonu Univ, Tip Fak, Goz Hastaliklari Anabilim Dali, Malatya, Turkey
[2] Inonu Univ, Tip Fak, Biyoistat Anabilim Dali, Malatya, Turkey
来源
TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY | 2008年 / 38卷 / 06期
关键词
Age; central corneal thickness; anterior chamber depth; corneal volume; anterior chamber volume; anterior chamber angle; pentacam;
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine the mean values and standard deviations of anterior chamber parameters with pentacam and evaluate the alterations of these parameters with age. Material-Method: 224 eyes of 112 patients with just basic refractive errors were included in this study. After complete ophthalmologic examination of patients, under standard conditions anterior chamber parameters were measured with pentacam. Central corneal thickness (CCT), anterior chamber depth (ACD), corneal volume (CV), anterior chamber volume (ACV), anterior chamber angle (ACA), and also horizontal, vertical and mean keratometry values were recorded with pentacam. Results: 55 female and 57 male patients were included in this study. Mean age of patients was 28.57. Mean of the keratometric measurements was 43.1 D. Mean values for CCT, ACD, CV, ACV and ACA were 534 mu m, 3.14 mm, 59.77 mm(3), 190.26 mm(3), 36.88 degrees, respectively. Evaluation of parameters according to gender and eye distribution did not reveale any difference. Analysis the effect of age on CCT, ACD, CV, ACV and ACA parameters documented statistical significance (p< 0.005) and correlation coefficents were r=-0.185, -0.373, -0.263, -0.320, -0.264, respectively. Conclusion: This study documented the negative effect of age on the anterior chamber parameters with different correlation coefficients.
引用
收藏
页码:452 / 458
页数:7
相关论文
共 21 条
  • [1] Comparison of central corneal thickness measurements by rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit corneal topography
    Amano, S
    Honda, N
    Amano, Y
    Yamagami, S
    Miyai, T
    Samejima, T
    Ogata, M
    Miyata, K
    [J]. OPHTHALMOLOGY, 2006, 113 (06) : 937 - 941
  • [2] Corneal-thickness spatial profile and corneal-volume distribution: Tomographic indices to detect keratoconus
    Ambrosio, Renato, Jr.
    Alonso, Ruiz Simonato
    Luz, Allan
    Coca Velarde, Luis Guillermo
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (11) : 1851 - 1859
  • [3] Comparison of three methods of measuring corneal thickness and anterior chamber depth
    Buehl, W
    Stojanac, D
    Sacu, S
    Drexler, W
    Findl, O
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (01) : 7 - 12
  • [4] Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach
    Doughty, MJ
    Zaman, ML
    [J]. SURVEY OF OPHTHALMOLOGY, 2000, 44 (05) : 367 - 408
  • [5] Comparison of different techniques of anterior chamber depth and keratometric measurements
    Elbaz, Uri
    Barkana, Yaniv
    Gerber, Yariv
    Avni, Isaac
    Zadok, David
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (01) : 48 - 53
  • [6] Evaluation of anterior segment parameters in keratoconic eyes measured with the Pentacam system
    Emre, Sinan
    Doganay, Selim
    Yologlu, Saim
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (10) : 1708 - 1712
  • [7] Erdurmufl M, 2007, T OFT GAZ, V37, P3
  • [8] Slit-scan tomography evaluation of the anterior chamber and corneal configurations at different ages
    Jonsson, M
    Markström, K
    Behndig, A
    [J]. ACTA OPHTHALMOLOGICA SCANDINAVICA, 2006, 84 (01): : 116 - 120
  • [9] Central and peripheral pachymetry measurements according to age using the Pentacam rotating Scheimpflug camera
    Khoramnia, Rarnin
    Rabsilber, Tanja M.
    Auffarth, Gerd U.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (05) : 830 - 836
  • [10] Recent advances in ophthalmic anterior segment imaging: a new era for ophthalmic diagnosis?
    Konstantopoulos, Aristides
    Hossain, Parwez
    Anderson, David F.
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (04) : 551 - 557