CONTROLLED CLINICAL-EVALUATION OF BACTEC PLUS AEROBIC/F AND BACT/ALERT AEROBIC FAN BOTTLES FOR DETECTION OF BLOOD-STREAM INFECTIONS

被引:57
作者
POHLMAN, JK
KIRKLEY, BA
EASLEY, KA
BASILLE, BA
WASHINGTON, JA
机构
[1] CLEVELAND CLIN FDN,DEPT CLIN PATHOL L40,CLEVELAND,OH 44195
[2] CLEVELAND CLIN FDN,DEPT BIOSTAT & EPIDEMIOL,CLEVELAND,OH 44195
关键词
D O I
10.1128/JCM.33.11.2856-2858.1995
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
A total of 7,190 blood culture sets were obtained from adult patients with a suspected bloodstream infection. A 20-ml sample of blood was distributed equally between the aerobic FAN bottle which was monitored in the BacT/Alert system and a Plus Aerobic/F bottle which was monitored in the BACTEC 9240 system, A total of 988 positive cultures were obtained from 483 patients; however, only 453 positive cultures from 173 patients met the criteria for volume (greater than or equal to 8 mi per bottle) and clinical significance on the basis of concurrent case review required for data analysis, There were 25 and 68 false positives from the FAN and Plus Aerobic/F bottles, respectively, There were no statistically significant differences between systems in the number of positive cultures or septic episodes by species; however, the total number of Enterobacteriaceae and Pseudomonas aeruginosa isolates combined was significantly greater in the FAN bottle (P = 0.04), Detection times did not differ significantly between systems for positive cultures; however, episodes of Staphylococcus aureus bacteremia were detected significantly more rapidly from the FAN bottle ( = 0.005), There was no significant difference between systems in the detection of bloodstream infections in patients receiving antibiotics at the time of blood culture.
引用
收藏
页码:2856 / 2858
页数:3
相关论文
共 13 条
[1]   INCREASED DETECTION OF STAPHYLOCOCCAL BACTEREMIA USING AN ANTI-MICROBIAL REMOVAL DEVICE [J].
CARLSON, LG ;
TENOVER, FC ;
PLORDE, JJ .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1985, 84 (04) :509-512
[2]   ROUTINE EVALUATION OF BACTEC NR-16A AND NR-17A MEDIA [J].
COURCOL, RJ ;
DUROCHER, AV ;
ROUSSELDELVALLEZ, M ;
FRUCHART, A ;
MARTIN, GR .
JOURNAL OF CLINICAL MICROBIOLOGY, 1988, 26 (09) :1619-1622
[3]   DETECTION OF BACTEREMIA WITH THE BACTEC B-16 RESIN BLOOD CULTURE-MEDIUM [J].
DEGIROLAMI, PC ;
EICHELBERGER, K ;
SIEGEL, J .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1984, 81 (05) :643-646
[4]   DETECTION OF BACTEREMIA IN PATIENTS RECEIVING ANTI-MICROBIAL THERAPY - AN EVALUATION OF THE ANTI-MICROBIAL REMOVAL DEVICE AND B-16 MEDIUM [J].
DOERN, GV ;
GANTZ, NM .
JOURNAL OF CLINICAL MICROBIOLOGY, 1983, 18 (01) :43-48
[5]   CDC DEFINITIONS FOR NOSOCOMIAL INFECTIONS, 1988 [J].
GARNER, JS ;
JARVIS, WR ;
EMORI, TG ;
HORAN, TC ;
HUGHES, JM .
AMERICAN JOURNAL OF INFECTION CONTROL, 1988, 16 (03) :128-140
[6]  
ILSTRUP DM, 1978, DETECTION SEPTICEMIA, P31
[7]   CLINICAL COMPARISON OF ISOLATOR AND BACTEC-660 RESIN MEDIA FOR BLOOD CULTURE [J].
KELLY, MT ;
ROBERTS, FJ ;
HENRY, D ;
GEERE, I ;
SMITH, JA .
JOURNAL OF CLINICAL MICROBIOLOGY, 1990, 28 (09) :1925-1927
[8]   MULTICENTER COMPARISON OF THE HIGH-VOLUME (10 ML) NR BACTEC PLUS SYSTEM AND THE STANDARD (5 ML) (NR BACTEC SYSTEM [J].
KOONTZ, FP ;
FLINT, KK ;
REYNOLDS, JK ;
ALLEN, SD .
DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 1991, 14 (02) :111-118
[9]   EVALUATION OF THE BACTEC ANTI-MICROBIAL REMOVAL SYSTEM FOR DETECTION OF BACTEREMIA [J].
MCGUIRE, NM ;
KAUFFMAN, CA ;
HERTZ, CS ;
KOVACH, JM .
JOURNAL OF CLINICAL MICROBIOLOGY, 1983, 18 (03) :449-451
[10]   EVALUATION OF NEW BLOOD CULTURE PROCESSING SYSTEMS [J].
MOODY, JA ;
FASCHING, CE ;
SHANHOLTZER, CJ ;
GERDING, DN ;
PETERSON, LR .
JOURNAL OF CLINICAL MICROBIOLOGY, 1984, 20 (03) :351-356