THE 2-STEP ELECTROCHEMICAL ETCHING TECHNIQUE APPLIED FOR POLYCARBONATE TRACK ETCHED DETECTORS

被引:0
|
作者
PIESCH, E
ALNAJJAR, SAR
JOZEFOWICZ, K
机构
[1] LEICESTER ROYAL INFIRM,LEICESTER LE2 7LX,ENGLAND
[2] INST ATOM ENERGY,OTWOCK,POLAND
来源
关键词
MAKROFOL DE; NEUTRONS; ALPHA PARTICLES; ENERGY RESPONSE; 2-STEP ELECTROCHEMICAL ETCHING;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The two-step ECE technique was optimized by varying the electrical field strength and applied for Makrofol DE for neutron dosimetry and radon monitoring using an electric field strength of 26.7 kV.cm-1. In comparison with the previously applied combination of chemical and electro-chemical etching, the neutron response was increased above a threshold of about 1.5 MeV by a factor of 3 to a value of 52 tracks.cm-1.mSv-1. The background track density and its standard deviation of (6 +/- 2) cm-2 allows to indicate already 0.1 mSv. The alpha energy range was extended from an alpha window of about 1.5 MeV to an alpha energy range from 0.5 to 4 MeV.
引用
收藏
页码:205 / 210
页数:6
相关论文
共 50 条
  • [1] Optimisation and modelling of electrochemically etched polycarbonate track detectors
    Univ of Leuven, Leuven, Belgium
    Nucl Instrum Methods Phys Res Sect B, 1 (65-72):
  • [2] Optimisation and modelling of electrochemically etched polycarbonate track detectors
    Vancraeynest, G
    Franchoo, S
    Huyse, M
    Moons, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1997, 129 (01): : 65 - 72
  • [3] ELECTROCHEMICAL ETCHING OF PLASTIC TRACK DETECTORS
    DYAKOV, AA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1984, 27 (02) : 253 - 262
  • [4] Polycarbonate track etched detectors for qualitative alpha spectroscopy in radon environments
    Burgkhardt, B
    Kupschus, A
    Vilgis, M
    Piesch, E
    Dorschel, B
    RADIATION PROTECTION DOSIMETRY, 1996, 66 (1-4) : 331 - 334
  • [5] ELECTRO-CHEMICAL ETCHING IN POLYCARBONATE NEUTRON TRACK DETECTORS
    KENAWY, MA
    ELFIKI, MA
    EISSA, HM
    SHARAF, MA
    GOMMA, MA
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1984, 8 (1-4): : 621 - 625
  • [6] NEW ETCHING TECHNIQUE FOR DAMAGE TRACK DETECTORS
    TOMMASINO, L
    ARMELLINI, C
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 1973, 20 (04): : 253 - 255
  • [7] UNIVERSAL MULTIDETECTOR ETCHING STAND FOR ELECTROCHEMICALLY ETCHED PLASTIC TRACK DETECTORS
    TUREK, K
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1992, 20 (04): : 601 - 604
  • [8] Study of current drain during electrochemical etching of polycarbonate detectors
    Zainali, G
    Afkar, A
    RADIATION MEASUREMENTS, 2005, 40 (2-6) : 337 - 342
  • [9] A NEW PARAMETER IN THE ELECTROCHEMICAL ETCHING OF POLYMER TRACK DETECTORS
    SOHRABI, M
    KATOUZI, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1993, 82 (03): : 442 - 446
  • [10] Effect of etching conditions on pore shape in etched ion-track polycarbonate membranes
    Karim, S.
    Ensinger, W.
    Mujahid, S. A.
    Maaz, K.
    Khan, E. U.
    RADIATION MEASUREMENTS, 2009, 44 (9-10) : 779 - 782