FLOW-INJECTION ANALYSIS AND BIOSENSORS - APPLICATIONS FOR BIOTECHNOLOGY AND ENVIRONMENTAL-CONTROL

被引:33
作者
LUDI, H
GARN, MB
BATAILLARD, P
WIDMER, HM
机构
[1] Central Analytical Research, CIBA-GEIGY Ltd., Basel
关键词
Bioprocess control; Biosensor; Environmental control; Flow injection analysis;
D O I
10.1016/0168-1656(90)90019-8
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Our experience in industrial bioprocess monitoring and environmental control let us develop a concept for biosensor research which distinguishes itself from other, more popular, approaches. Biosensors must improve and/or simplify existing state-of-the-art analysis systems. Only the parallel development of biosensors and their complementary metrology leads to industrially sound solutions. The combination of flow injection analysis with immobilized enzymes in the form of enzyme columns is already used today for the solution of on-line analytical problems in bioprocesses and environmental control. © 1990.
引用
收藏
页码:71 / 79
页数:9
相关论文
共 17 条
[1]  
BRADFORD MM, 1976, ANAL BIOCHEM, V72, P248, DOI 10.1016/0003-2697(76)90527-3
[2]   BIOSENSORS IN PROCESS-CONTROL [J].
CLARKE, DJ ;
BERGMAN, I .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY OF LONDON SERIES B-BIOLOGICAL SCIENCES, 1987, 316 (1176) :169-181
[3]  
Danielsson B, 1976, Methods Enzymol, V44, P667
[4]   A FLOW-INJECTION ANALYSIS SYSTEM FOR FERMENTATION MONITORING AND CONTROL [J].
GARN, M ;
GISIN, M ;
THOMMEN, C ;
CEVEY, P .
BIOTECHNOLOGY AND BIOENGINEERING, 1989, 34 (04) :423-428
[5]   EXTENSIVE FLOW-INJECTION DILUTION FOR IN-LINE SAMPLE PRETREATMENT - COMPARISON BETWEEN SINGLE-STAGE AND DUAL-STAGE MODULES [J].
GARN, MB ;
GISIN, M ;
GROSS, H ;
KING, P ;
SCHMIDT, W ;
THOMMEN, C .
ANALYTICA CHIMICA ACTA, 1988, 207 (1-2) :225-231
[6]   FABRICATION AND CHARACTERIZATION OF A PLANAR ELECTROCHEMICAL-CELL AND ITS APPLICATION AS A GLUCOSE SENSOR [J].
GERNET, S ;
KOUDELKA, M ;
DEROOIJ, NF .
SENSORS AND ACTUATORS, 1989, 18 (01) :59-70
[7]   BIODEGRADATION OF CHEMICAL WASTE BY SPECIALIZED METHYLOTROPHS, AN ALTERNATIVE TO PHYSICAL METHODS OF WASTE-DISPOSAL [J].
GHISALBA, O ;
CEVEY, P ;
KUENZI, M ;
SCHAR, HP .
CONSERVATION & RECYCLING, 1985, 8 :47-71
[8]   INDUSTRIAL-PROCESS CONTROL BY FLOW-INJECTION ANALYSIS [J].
GISIN, M ;
THOMMEN, C .
ANALYTICA CHIMICA ACTA, 1986, 190 (01) :165-176
[9]   ARTIFICIAL REDUCTANT ENHANCEMENT OF THE LOWRY METHOD FOR PROTEIN DETERMINATION [J].
LARSON, E ;
HOWLETT, B ;
JAGENDORF, A .
ANALYTICAL BIOCHEMISTRY, 1986, 155 (02) :243-248
[10]  
LOWRY OH, 1951, J BIOL CHEM, V193, P265