PROGNOSTIC FACTORS OF LOCAL OUTCOME FOR T1, T2 CARCINOMAS OF ORAL TONGUE TREATED BY IR-192 IMPLANTATION

被引:49
作者
MAZERON, JJ
CROOK, JM
MARINELLO, G
WALOP, W
PIERQUIN, B
机构
[1] OTTAWA REG CANC CTR,501 SMYTH RD,OTTAWA K1H 8L6,ONTARIO,CANADA
[2] HOP HENRI MONDOR,DEPT CANCEROL,F-94010 CRETEIL,FRANCE
[3] UNIV OTTAWA,DEPT EPIDEMIOL & COMMUNITY MED,OTTAWA K1N 6N5,ONTARIO,CANADA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1990年 / 19卷 / 02期
关键词
Carcinoma of tongue; Implantation; Iridium;
D O I
10.1016/0360-3016(90)90535-R
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The results of Iridium 192 implantation for 121 node negative TI or T2 squamous carcinomas of mobile tongue were reviewed to look for predictors of local control and necrosis. Age, sex, total dose, dose rate, linear activity, and intersource spacing were examined. Minimum follow-up was 2 years but no patient with local recurrence or necrosis was excluded. There were 57 T1N0 tumors, 45 T2aN0 (2.1-3.0 cm), and 19 T2bN0 (3.1-4.0 cm). Local failures occurred in 14% of T1, I1% of T2a, and 26% of T2b. Univariate analysis showed that local control increased with increasing dose (55-60 Gy: 73%; 65-75 Gy: 92%, p = 0.005), whereas multivariate analysis revealed both sex and total dose to be significant. Radiation necrosis occurred in 17% of T1, 29% of T2a, and 47% of T2b (p = 0.034). Half were limited to soft tissue and the majority healed with conservative management. Univariate analysis showed that necrosis increased with increasing dose (55-60 Gy: 16%; 65-75 Gy: 33%, p = 0.037), as well as increasing dose rate, linear activity, and intersource spacing. With multivariate analysis only stage, dose rate, and spacing remained predictive of necrosis. Total dose was not adjusted for dose rate or tumor volume. This analysis suggests that within the therapeutic range of low dose rate brachytherapy, correction of total dose according to dose rate is unnecessary. We recommend 65 Gy. Lower dose rate (0.4-0.5 Gy/hr) and closer intersource spacing (12-14 mm) should be aimed for to minimize necrosis. © 1990.
引用
收藏
页码:281 / 285
页数:5
相关论文
共 24 条
[1]   INFLUENCE OF TUMOR DOSE SPECIFICATION ON EARLY CLINICAL RESULTS OF INTERSTITIAL RADIUM TONGUE IMPLANTS [J].
AWWAD, HK ;
BURGERS, JMV ;
MARCUSE, HR .
RADIOLOGY, 1974, 110 (01) :177-182
[2]   STUDIES IN DOSE-TIME-VOLUME RELATIONSHIPS IN BLADDER AND TONGUE RADIUM IMPLANTS [J].
AWWAD, HK ;
BURGERS, JMV .
CLINICAL RADIOLOGY, 1976, 27 (04) :443-448
[3]   RELATION BETWEEN LOCAL CURE AND DOSE-TIME-VOLUME FACTORS IN INTERSTITIAL IMPLANTS [J].
BURGERS, JMV ;
AWWAD, HK ;
VANDERLAARSE, R .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1985, 11 (04) :715-723
[4]  
DUTRIEX A, 1989, RADIOTHER ONCOL, V15, P25
[5]  
DUTRIEX A, 1981, DOSIMETRIE CURIETHER
[6]  
ESCHE B, 1989, ANN RCPSC, V22, P351
[7]  
FEROLDI P, 1986, STRAHLENTHER ONKOL, V162, P561
[8]   EFFECT OF DOSE-RATE ON LOCAL-CONTROL AND COMPLICATIONS IN THE REIRRADIATION OF HEAD AND NECK TUMORS WITH INTERSTITIAL IR-192 [J].
FONTANESI, J ;
HETZLER, D ;
ROSS, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 17 (02) :365-369
[9]   TIME, DOSE AND VOLUME FACTORS IN INTERSTITIAL RADIUM IMPLANTS OF CARCINOMA OF ORAL TONGUE [J].
FU, KK ;
CHAN, EK ;
PHILLIPS, TL ;
RAY, JW .
RADIOLOGY, 1976, 119 (01) :209-213
[10]   INTERSTITIAL TIME-DOSE CORRECTIONS [J].
JOHNSON, GC .
RADIOLOGY, 1964, 82 (05) :831-832