ACCURATE INTERNAL CORRECTION FOR THE MAGNIFICATION OF CINEANGIOCARDIOGRAPHY IN INFANTS WITH CONGENITAL HEART-DISEASE

被引:6
作者
BAYLEN, BG
OGATA, H
FRENCH, WJ
EMMANOUILIDES, GC
机构
[1] UNIV CALIF LOS ANGELES, LOS ANGELES CTY HARBOR MED CTR, DEPT PEDIAT, DIV PEDIAT CARDIOL, TORRANCE, CA 90509 USA
[2] UNIV CALIF LOS ANGELES, SCH MED, LOS ANGELES, CA 90024 USA
关键词
D O I
10.1016/0002-8703(84)90143-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Correction for X-ray magnification at cineangiocardiography (cine) requires accurate localization of the level of the left ventricle (LV). This study compared LV volumes calculated using a standard external reference object (area grid) with volumes calculated using an intracardiac radiopaque catheter balloon in cine studies of casts (n = 26), normal lambs (n = 15) and infants with congenital heart disease (n = 11). Comparisons of LV volumes calculated using both correctioon methods with true cast displacement volumes were excellent (r = 0.99). Correlations of both methods were highly significant (P < 0.001) in casts (r = 0.99), normal lambs (r = 0.97) and in infants (r = 0.83). The absolute percent difference (17.6 .+-. 2.4 SE%) between LV volumes calculated by both methods was greatest in infants. External localization of the LV may be more difficult in infants. The radiopaque balloon provides convenient accurate correction for cine X-ray magnification and calculation of LV volumes, particularly since flow-directed catheters are widely used for diagnostic cine ventriculography in infants.
引用
收藏
页码:113 / 118
页数:6
相关论文
共 16 条
[1]   NEW METHOD FOR PRECISE AND COMPLETE CORRECTION OF DISTORTION ON CINEANGIOGRAPHIC IMAGE - ITS EFFECT ON LEFT-VENTRICULAR MEASUREMENTS [J].
BONARD, P ;
TREMBLAY, G ;
LEBLANC, AR ;
BERTRAND, M ;
ROBERGE, FA .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1978, 4 (02) :111-126
[2]   EXPERIENCES WITH A CINEFLUOROGRAPHIC METHOD FOR MEASURING VENTRICULAR VOLUME [J].
CHAPMAN, CB ;
BAKER, O ;
MITCHELL, JH ;
COLLIER, RG .
AMERICAN JOURNAL OF CARDIOLOGY, 1966, 18 (01) :25-+
[3]   THE USE OF BIPLANE ANGIOCARDIOGRAPHY FOR THE MEASUREMENT OF LEFT VENTRICULAR VOLUME IN MAN [J].
DODGE, HT ;
SANDLER, H ;
BALLEW, DW ;
LORD, JD .
AMERICAN HEART JOURNAL, 1960, 60 (05) :762-776
[4]   USEFULNESS AND LIMITATIONS OF RADIOGRAPHIC METHODS FOR DETERMINING LEFT VENTRICULAR VOLUME [J].
DODGE, HT ;
SANDLER, H ;
BAXLEY, WA ;
HAWLEY, RR .
AMERICAN JOURNAL OF CARDIOLOGY, 1966, 18 (01) :10-&
[5]  
ELLIOTT LP, 1977, CIRCULATION, V56, P1084
[6]   ANGIOGRAPHIC ESTIMATION OF LEFT-VENTRICULAR VOLUME [J].
GAULT, JH .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1975, 1 (01) :7-16
[7]   LEFT HEART VOLUME ESTIMATION IN INFANCY AND CHILDHOOD - REEVALUATION OF METHODOLOGY AND NORMAL VALUES [J].
GRAHAM, TP ;
JARMAKANI, JM ;
CANENT, RV ;
MORROW, MN .
CIRCULATION, 1971, 43 (06) :895-+
[8]   ESTIMATION OF LEFT VENTRICULAR VOLUME BY 1-PLANE CINEANGIOGRAPHY [J].
GREENE, DG ;
CARLISLE, R ;
GRANT, C ;
BUNNELL, IL .
CIRCULATION, 1967, 35 (01) :61-&
[9]   COMPARISON OF LEFT VENTRICULAR VOLUMES BY DYE DILUTION AND ANGIOGRAPHIC METHODS IN DOG [J].
HALLERMANN, FJ ;
SWAN, HJC ;
RASTELLI, GC .
AMERICAN JOURNAL OF PHYSIOLOGY, 1963, 204 (03) :446-&
[10]   MEASUREMENT OF LEFT VENTRICULAR VOLUMES IN MAN BY SINGLE-PLANE CINEANGIOCARDIOGRAPHY [J].
KASSER, IS ;
KENNEDY, JW .
INVESTIGATIVE RADIOLOGY, 1969, 4 (02) :83-&