SPIRAL CT OF RENAL-ARTERY STENOSIS - COMPARISON OF 3-DIMENSIONAL RENDERING TECHNIQUES

被引:288
作者
RUBIN, GD
DAKE, MD
NAPEL, S
JEFFREY, RB
MCDONNELL, CH
SOMMER, FG
WEXLER, L
WILLIAMS, DM
机构
[1] Department of Radiology, Stanford Univ. Hosp. and Med. Center, Stanford, CA 94305-5105
关键词
ANGIOGRAPHY; TECHNOLOGY; ARTERIES; COMPUTED TOMOGRAPHY (CT); HELICAL TECHNOLOGY; 3-DIMENSIONAL; RENAL ANGIOGRAPHY; RENAL ARTERIES; STENOSIS OR OBSTRUCTION;
D O I
10.1148/radiology.190.1.8259402
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the accuracy of computed tomographic (CT) angiography in the detection of renal artery stenosis (RAS). MATERIALS AND METHODS: CT angiography was performed in 31 patients undergoing conventional renal arteriography. CT angiographic data were reconstructed with shaded surface display (SSD) and maximum-intensity projection (MIP). Stenosis was graded with a four-point scale (grades 0-3). The presence of mural calcification, poststenotic dilatation, and nephrographic abnormalities was also noted. RESULTS: CT angiography depicted all main (n = 62) and accessory (n = 11) renal arteries that were seen at conventional arteriography. MIP CT angiography was 92% sensitive and 83% specific for the detection of grade 2-3 stenoses (greater than or equal to 70% stenosis). SSD CT angiography was 59% sensitive and 82% specific for the detection of grade 2-3 stenoses. The accuracy of stenosis grading was 80% with MIP and 55% with SSD CT angiography. Poststenotic dilatation and the presence of an abnormal nephrogram were 85% and 98% specific, respectively. CONCLUSION: CT angiography shows promise in the diagnosis of RAS. The accuracy of CT angiography varies with the three-dimensional rendering technique employed.
引用
收藏
页码:181 / 189
页数:9
相关论文
共 15 条
[1]  
BOIJSEN E, 1959, Acta Radiol Suppl, V183, P1
[2]  
BRINK JA, 1992, RADIOLOGY, V185, P126
[3]   3D RECONSTRUCTION OF THE BRAIN FROM MAGNETIC-RESONANCE IMAGES USING A CONNECTIVITY ALGORITHM [J].
CLINE, HE ;
DUMOULIN, CL ;
HART, HR ;
LORENSEN, WE ;
LUDKE, S .
MAGNETIC RESONANCE IMAGING, 1987, 5 (05) :345-352
[4]  
EDSMAN G, 1957, ACTA RADIOL STOCKH S, V155, P5
[5]   RENAL ARTERIAL STENOSES - SPIRAL CT ANGIOGRAPHY [J].
GALANSKI, M ;
PROKOP, M ;
CHAVAN, A ;
SCHAEFER, CM ;
JANDELEIT, K ;
NISCHELSKY, JE .
RADIOLOGY, 1993, 189 (01) :185-192
[6]   IMAGING ADVANCES IN THE DIAGNOSIS OF RENOVASCULAR HYPERTENSION [J].
HILLMAN, BJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (01) :5-14
[7]   SPIRAL VOLUMETRIC CT WITH SINGLE-BREATH-HOLD TECHNIQUE, CONTINUOUS TRANSPORT, AND CONTINUOUS SCANNER ROTATION [J].
KALENDER, WA ;
SEISSLER, W ;
KLOTZ, E ;
VOCK, P .
RADIOLOGY, 1990, 176 (01) :181-183
[8]   MR ANGIOGRAPHY WITH TWO-DIMENSIONAL ACQUISITION AND 3-DIMENSIONAL DISPLAY - WORK IN PROGRESS [J].
KELLER, PJ ;
DRAYER, BP ;
FRAM, EK ;
WILLIAMS, KD ;
DUMOULIN, CL ;
SOUZA, SP .
RADIOLOGY, 1989, 173 (02) :527-532
[9]   EVALUATION OF METHODS FOR SHADED SURFACE DISPLAY OF CT VOLUMES [J].
MAGNUSSON, M ;
LENZ, R ;
DANIELSSON, PE .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1991, 15 (04) :247-256
[10]  
MERKLIN R J, 1958, J Int Coll Surg, V29, P41