FRACTIONAL AEROSOL FILTRATION EFFICIENCY OF IN-DUCT VENTILATION AIR CLEANERS

被引:104
|
作者
HANLEY, JT [1 ]
ENSOR, DS [1 ]
SMITH, DD [1 ]
SPARKS, LE [1 ]
机构
[1] US EPA,AIR & ENERGY ENGN RES LAB,RES TRIANGLE PK,NC 27711
来源
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE | 1994年 / 4卷 / 03期
关键词
AIR CLEANER; AEROSOL; FILTRATION; EFFICIENCY; FRACTIONAL;
D O I
10.1111/j.1600-0668.1994.t01-1-00005.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The filtration efficiency of ventilation air cleaners is highly particle-size dependent over the 0.01 to 3 mu m diameter size range. Current standardized test methods, which determine only overall efficiencies for ambient aerosol or other test aerosols, provide data of limited utility. Because particles in this range are respirable and can remain airborne for prolonged time periods, measurement of air cleaner fractional efficiency is required for application to indoor air quality issues. The objectives of this work have been to 1) develop a test apparatus and procedure to quantify the the fractional filtration efficiency of air cleaners over the 0.01 to 3 mu m diameter size range and 2) quantify the fractional efficiency of several induct air cleaners typical of those used in residential and office ventilation systems. Results show that efficiency is highly dependent on particle size, flow rate, and dust load present on the air cleaner. A minimum in efficiency was often observed in the 0.1 to 0.5 mu m diameter size range. The presence of a dust load frequently increased an air cleaner's efficiency; however, some air cleaners showed little change or a decrease in efficiency with dust loading. The common furnace filter had fractional efficiency values of less than 10% over much of the measurement size range.
引用
收藏
页码:169 / 178
页数:10
相关论文
共 50 条
  • [1] Laboratory testing of full-scale in-duct gas air cleaners
    VanOsdell, Douglas W.
    Rodes, Charles E.
    Owen, M. Kathleen
    ASHRAE Transactions 2006, Vol 112, Pt 2, 2006, 112 : 418 - 429
  • [2] Classroom scale measurements of the efficacy of ventilation, filtration, and electronic air cleaners for the removal of aerosol particles
    Gord, Joseph
    Vigil, Correy
    Richards, Stephanie
    Bertram, Timothy H.
    BUILDING AND ENVIRONMENT, 2023, 244
  • [3] A new laboratory test method for measuring the bioaerosol filtration efficiency of air cleaners
    Foarde, KK
    Hanley, JT
    AIR FILTRATION CONFERENCE, PROCEEDINGS, 1999, : 47 - 54
  • [4] Whole House Particle Removal and Clean Air Delivery Rates for In-Duct and Portable Ventilation Systems
    Macintosh, David L.
    Myatt, Theodore A.
    Ludwig, Jerry F.
    Baker, Brian J.
    Suh, Helen H.
    Spengler, John D.
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2008, 58 (11) : 1474 - 1482
  • [5] Indoor air aerosol model: the effect of outdoor air, filtration and ventilation on indoor concentrations
    Kulmala, M
    Asmi, A
    Pirjola, L
    ATMOSPHERIC ENVIRONMENT, 1999, 33 (14) : 2133 - 2144
  • [6] Performance comparison of residential in-duct air cleaning devices
    Kinzer, KE
    Moreno, RC
    ADVANCES IN FILTRATION AND SEPARATION TECHNOLOGY, VOL 11 1997, 1997, : 252 - 263
  • [7] Performance Comparison of Residential In-duct Air Cleaning Devices
    Kinzer, K. E.
    Moreno, R. C.
    Fluid/Particle Separation Journal: A Publication of the American Filtration Society, 10 (03):
  • [8] CHANGE IN ROOM AEROSOL CONCENTRATION BY IN-DUCT COMPLEX ELECTRIC-FIELDS
    FREY, AH
    JOURNAL OF ENVIRONMENTAL SCIENCES, 1984, 27 (01): : 34 - 36
  • [9] Filtration efficiency of industrial vacuum cleaners - testing method
    Regnier, R.
    Bemer, D.
    Subra, I.
    GEFAHRSTOFFE REINHALTUNG DER LUFT, 2009, 69 (05): : 205 - 212
  • [10] FILTRATION-AIR CLEANERS SHARE SHOW SPOTLIGHT
    ROSENZWE.MD
    CHEMICAL ENGINEERING, 1973, 80 (27) : 28 - 30